Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

CRC Press eBooks

Vibrational Dephasing in Liquids: Raman Echo and Raman Free-Induction Decay Studies

Mark A. Berg

Published Mar 16, 2001• 2 citations
Publisher
DOI
10.1201/9780203904763.ch9

Related papers

Raman echo studies of vibrational dephasing in liquids

Mark A. Berg, Laura Müller, David Vanden Bout

Quantum Electronics and Laser Science Conference•May 10, 1992•0 citations

Selectivity in coherent transient Raman measurements of vibrational dephasing in liquids

Roger F. Loring, Shaul Mukamel

The microscopic information content of coherent transient Raman measurements is analyzed. It is shown that for short pulses and optically thin samples the Kaiser–Laubereau pulse sequence is the Raman analog of the optical free induction decay, and that the experimental observable contains the same dynamical information as the isotropic, spontaneous Raman line shape. Under these conditions, the experiment therefore cannot be used to selectively measure the homogeneous dephasing time of a system with an inhomogeneously broadened line. The results of our analysis are at variance with the earlier results of Kaiser and Laubereau and the more recent predictions of Oxtoby. However, these experiments, under certain circumstances, may be used to obtain a nonselective line narrowing, as found by Zinth, Polland, Laubereau, and Kaiser. We also consider the situation in which the sample is optically dense, in which case laser depletion must be taken into account. The distinction between saturation of the vibrational transition and depletion of the pump pulse is discussed, and selectivity is shown to arise from the former phenomenon, rather than from the latter. This result is at variance with the predictions of George and Harris. An alternative pulse sequence, the Raman echo, is suggested as a tool to achieve selectivity. A unified theory of the Raman echo is developed, which is valid for a bath with arbitrary time scale and which interpolates between the limits of homogeneous and inhomogeneous line broadening.

The Journal of Chemical Physics•Sep 1, 1985•196 citations

Coherent processes at surfaces: Free-induction decay and photon echo of the Si-H stretching vibration for H/Si(111)

Philippe Guyot‐Sionnest

Using short infrared pulses and sum-frequency up-conversion, the dephasing of the transient polarization of the Si-H adsorbate-substrate vibration is followed in real time. At 120 K, dephasing due to homogeneous linewidth or inhomogeneous broadening are separated.

Physical Review Letters•Mar 18, 1991•183 citations

Effects of dampings and dephasings in resonance raman spectroscopy

Pier Francesco Fracassi, Leonardo Angeloni, Raffaele Guido Della Valle

Chemical Physics Letters•Apr 1, 1985•5 citations

Dephasing in steady-state and time-varying spectroscopy

Iu. E. Diakov

ZhETF Pisma Redaktsiiu•Jan 1, 1983•2 citations

Efficient generation of Raman echo and time-domain optical data storage by electromagnetically induced transparency

Myung K. Kim, Philip Hemmer, Byoung Seung HAM +1 more

We have observed excitation of spin echoes and spin free induction decay (FID) by electromagnetically induced transparency (EIT) in an optically dense solid sample. The experiments are done in a double-lambda system of 605.7 nm 3H4 - 1D2 transition of Pr3+:Y2SiO5, where the 10.2 MHz ground state spin coherence is excited by low-power resonant Raman pulses. It has been shown that the spin coherence, including spin echo, is equivalent to the transparent state of EIT, and therefore a high efficiency is expected for such resonant Raman-excited spin echo. The observed efficiency of spin echo is as high as 75% of the FID signal at 5K. A background-free detection scheme is used based on EIT and enhanced nondegenerate four-wave mixing. The technique is applied in the frequency-selective time-domain optical data storage, that utilizes the spin as well as the optical inhomogeneous spectral widths. The data storage scheme is analogous to the stimulated spin echo with resonant Raman excitation of the spin coherence. We verify that the write window is determined by the spin T2 which is much longer than the optical T2, especially at higher temperature. We find that the spin dephasing time T2 is almost constant at approximately 500 microseconds in the range of 2 to approximately 6 K, whereas the optical T2 decreases rapidly, by a factor of approximately 50, above 4 K. These results will be useful in the development of high capacity time-domain optical data storage operating at higher temperature.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 5, 1998•1 citation
The microscopic information content of coherent transient Raman measurements is analyzed. It is shown that for short pulses and optically thin samples the Kaiser–Laubereau pulse sequence is the Raman analog of the optical free induction decay, and that the experimental observable contains the same dynamical information as the isotropic, spontaneous Raman line shape. Under these conditions, the experiment therefore cannot be used to selectively measure the homogeneous dephasing time of a system with an inhomogeneously broadened line. The results of our analysis are at variance with the earlier results of Kaiser and Laubereau and the more recent predictions of Oxtoby. However, these experiments, under certain circumstances, may be used to obtain a nonselective line narrowing, as found by Zinth, Polland, Laubereau, and Kaiser. We also consider the situation in which the sample is optically dense, in which case laser depletion must be taken into account. The distinction between saturation of the vibrational transition and depletion of the pump pulse is discussed, and selectivity is shown to arise from the former phenomenon, rather than from the latter. This result is at variance with the predictions of George and Harris. An alternative pulse sequence, the Raman echo, is suggested as a tool to achieve selectivity. A unified theory of the Raman echo is developed, which is valid for a bath with arbitrary time scale and which interpolates between the limits of homogeneous and inhomogeneous line broadening.
We have observed excitation of spin echoes and spin free induction decay (FID) by electromagnetically induced transparency (EIT) in an optically dense solid sample. The experiments are done in a double-lambda system of 605.7 nm 3H4 - 1D2 transition of Pr3+:Y2SiO5, where the 10.2 MHz ground state spin coherence is excited by low-power resonant Raman pulses. It has been shown that the spin coherence, including spin echo, is equivalent to the transparent state of EIT, and therefore a high efficiency is expected for such resonant Raman-excited spin echo. The observed efficiency of spin echo is as high as 75% of the FID signal at 5K. A background-free detection scheme is used based on EIT and enhanced nondegenerate four-wave mixing. The technique is applied in the frequency-selective time-domain optical data storage, that utilizes the spin as well as the optical inhomogeneous spectral widths. The data storage scheme is analogous to the stimulated spin echo with resonant Raman excitation of the spin coherence. We verify that the write window is determined by the spin T2 which is much longer than the optical T2, especially at higher temperature. We find that the spin dephasing time T2 is almost constant at approximately 500 microseconds in the range of 2 to approximately 6 K, whereas the optical T2 decreases rapidly, by a factor of approximately 50, above 4 K. These results will be useful in the development of high capacity time-domain optical data storage operating at higher temperature.