Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Sinica Quantum Optica

Parameter Dependence of the Temperature of Cold Cesium Atoms in 3D Near-Resonance Optical Lattice

Junmin Wang

Published Jan 1, 2007• 0 citations
OpenAlex

Abstract

The four-beam 3D near-resonance optical lattice is introduced and experimentally realized based on the magneto-optical trap and optical molasses.The temperature of cold cesium atoms loaded into the lattice is measured via the short-distance time of flight(TOF) absorption spectrum.By changing the intensity and detuning of lattice beams,the lowest temperature in that case is obtained.The parameter dependence of the temperature of the cold atoms in lattice is experimentally investigated,and a comparison with the case of optical molasses is briefly discussed.

Related papers

Loading and cooling of cesium atoms in 3D optical lattice

Qiu Ying, Jun He, Yanhua Wang +4 more

A four-beam 3D near-resonant optical lattice system is implemented and cold atoms are loaded into the optical lattice based on cesium magneto-optical trap and optical molasses. The dependence of the final temperature due to the Sisyphus cooling on the intensity and the frequency detuning of optical lattice are experiemently investigated,and the lifetime of the cold atoms in optical lattice are measured via the short-distance time_of_flight absorption spectra.

Acta Physica Sinica•Jan 1, 2008•4 citations

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

Experimental study on laser cooling of cesium atoms by optical molasses

Jidong Hou, LI Yi-min, Donghai Yang +1 more

We have studied the relationship between the temperature of Cs cold atoms and the parameters of the cooling laser. The atoms are first cooled and captured by a magneto-optical trap and then further cooled by optical molasses. The temperature of atoms is measured by a time-of-flight method. For relatively large laser intensity and small detuning, the temperature depends linearly on the intensity-to-detuning ratio, and nonlinear relationship has also been found in other case.

Acta Physica Sinica (Overseas Edition)•Dec 1, 1998•2 citations

Influence of parameter errors on the temperature measurement of cold atoms via short-distance time-of-flight absorption spectra

He Jun, Wang Jing, Qiu Ying +4 more

The basic model and the experimental measurement method of short-distance time-of-flight absorption spectra for determining the temperature of cold atoms are described. Based on the realization of temperature measurement of cold cesium atoms in a magneto-optical trap,the influences of measurement errors of the three experimental parameters,namely the falling distance h,the initial Gaussian radius σ0 of the cold cloud, and the Gaussian radius σp of probe beam, on the determination of temperature have been analyzed and compared.

Acta Physica Sinica•Jan 1, 2008•0 citations

3D optical lattices cooling of ultracold Cs atoms

Hongliang Wang, Guosheng Feng, Yuqing Li +4 more

Laser cooling of atoms is the basis of researches on ultracold atoms and molecules. It is of great importance in the study of precision measurement and quantum simulation, etc. In order to obtain ultracold cesium atomic sample with a lower temperature and a higher density, as the starting point to create ultracold cesium ground state molecules, we demonstrate in this article a method which effectively overcomes the heating from the reabsorption of scattered light in magneto-optical trap to further reduce the ultracold atomic temperature by loading atoms into a 3D optical lattices. Based on obtaining the ultracold Cs atoms in a standard magneto-optical trap, we use the compressed magneto-optical trap technology to increase ultracold Cs atomic density. Efficient loading of ultracold Cs atoms is achieved by 3D optical lattices which constructed by four lasers; the temperature of the atoms is measured by time-of-flight method. We observed the cooling result that the temperature drops from ~60.0 μK to ~11.6 μK. We also explore the dependence of the atom numbers in the lattice on the frequency of lattice lasers, and lead to the conclusion that the loading rate of the optical lattices reaches its maximum when the lattices laser’s detuning is –15.5 GHz. In the meantime, this paper investigates the use of optical lattice to suppress the heating of the ultracold atoms due to the radiation photons, in this sense, our research has far-reaching significance. Our scheme is advantageous due to its relaxed starting temperature requirement, meaning that 3D DRSC can be directly accomplished in a standard single cell vapour-loaded MOT without reliance on any additional devices such as a Zeeman slower.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Feb 13, 2017•0 citations

Obtaining Ultra-cold Atoms by Optical Molasses Directly from Vapor

Jidong Hou

Usually the magneto\|optical trap(MOT)is used to obtain the cold atoms from the vapor.It is reported that experiments for obtaining the ultra\|cold cesium atoms by optical molasses directly from the vapor cell without MOT.The lowest temperature achieved for the cesium atomic cloud was 3?μK.The relationship between the temperature and the detuning of cooling laser was measured.

Acta Scicentiarum Naturalum Universitis Pekinesis•Jan 1, 2001•1 citation
The four-beam 3D near-resonance optical lattice is introduced and experimentally realized based on the magneto-optical trap and optical molasses.The temperature of cold cesium atoms loaded into the lattice is measured via the short-distance time of flight(TOF) absorption spectrum.By changing the intensity and detuning of lattice beams,the lowest temperature in that case is obtained.The parameter dependence of the temperature of the cold atoms in lattice is experimentally investigated,and a comparison with the case of optical molasses is briefly discussed.
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
The basic model and the experimental measurement method of short-distance time-of-flight absorption spectra for determining the temperature of cold atoms are described. Based on the realization of temperature measurement of cold cesium atoms in a magneto-optical trap,the influences of measurement errors of the three experimental parameters,namely the falling distance h,the initial Gaussian radius σ0 of the cold cloud, and the Gaussian radius σp of probe beam, on the determination of temperature have been analyzed and compared.
Laser cooling of atoms is the basis of researches on ultracold atoms and molecules. It is of great importance in the study of precision measurement and quantum simulation, etc. In order to obtain ultracold cesium atomic sample with a lower temperature and a higher density, as the starting point to create ultracold cesium ground state molecules, we demonstrate in this article a method which effectively overcomes the heating from the reabsorption of scattered light in magneto-optical trap to further reduce the ultracold atomic temperature by loading atoms into a 3D optical lattices. Based on obtaining the ultracold Cs atoms in a standard magneto-optical trap, we use the compressed magneto-optical trap technology to increase ultracold Cs atomic density. Efficient loading of ultracold Cs atoms is achieved by 3D optical lattices which constructed by four lasers; the temperature of the atoms is measured by time-of-flight method. We observed the cooling result that the temperature drops from ~60.0 μK to ~11.6 μK. We also explore the dependence of the atom numbers in the lattice on the frequency of lattice lasers, and lead to the conclusion that the loading rate of the optical lattices reaches its maximum when the lattices laser’s detuning is –15.5 GHz. In the meantime, this paper investigates the use of optical lattice to suppress the heating of the ultracold atoms due to the radiation photons, in this sense, our research has far-reaching significance. Our scheme is advantageous due to its relaxed starting temperature requirement, meaning that 3D DRSC can be directly accomplished in a standard single cell vapour-loaded MOT without reliance on any additional devices such as a Zeeman slower.