Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

TUNABLE VACUUM-ULTRA VIOLET RADIATION GENERATED BY TWO-PHTON RESONANTFOUR-WAVE DIFFERENCE MIXING IN Hg VAPOR

Huang Xian-ling, Zongju Xia, ZOU YING-HUA, 北京大学物理系,北京100871

Published Jan 1, 1990• 0 citations
Publisher

Abstract

Vacuum-ultra violet radiation is generated by 61S0-61D2 or 61S0-63D2 two photon resonant four-wave difference mixing (ω4=2ω1-ω3) in Hg vapor. VUV radiation is tunable when one of the input wave (ω3) is tuned, the tuning range is 184.9-187.5 nm. The mechanism of this frenquency conversion, for example, the two-photon and single-photon resonant enhancement and phase matching have been investigeted. The competing processes and saturation effect on conversion efficiency have been analyzed. Using the generated tunable VUV radiation, we have recorded the absorption spetrum of O2 in air.

DOI
10.7498/aps.39.1385

Related papers

Generation of continuously tunable coherent vacuum-ultraviolet radiation in Cd vapor

Kenzo Miyazaki, Hirofumi Sakai, Takuzo Sato

Continuously tunable coherent vacuum-ultraviolet (VUV) radiation has been generated in the 128.7-135.3-nm region by two-photon resonant four-wave mixing in Cd vapor. The generated VUV has no spectral structure over the tuning range and indicates that Cd vapor is an efficient nonlinear medium for frequency conversion.

Optics Letters•Oct 1, 1984•22 citations

Generation of high-brightness coherent radiation in the vacuum ultraviolet by four-wave parametric oscillation in mercury vapor

Jeffrey Bokor, Richard R. Freeman, R. L. Panock +1 more

Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A frequency-doubled dye laser tuned to two-photon resonance with the 6s6d(1)D(2) level near 280.3 nm produced output at 184.9 and 143.5 nm. A tunable krypton fluoride excimer laser tuned to two-photon resonance with the 6s10s (1)S(0) level near 248.7 nm produced output at 140.1, 130.7, 130.1, 125.9, and 125.0 nm. Approximately 1-microJ, 200-W pulses were observed at 143.5 and 125.9 nm.

Optics Letters•Apr 1, 1981•62 citations

Enhanced production of coherent vuv radiation by four-wave mixing in Sr vapor

Gary C. Bjorklund, John E. Bjorkholm, Richard R. Freeman +1 more

Significant enhancement of the unsaturated conversion efficiencies of four-wave sum frequency mixing processes involving autoionizing states in Sr vapor is obtained by utilizing the 5s7s 1S0 two-photon channel and phase matching by frequency adjustment. Extrapolation to low power levels indicates that production of cw vuv radiation may be possible. A saturation effect arising from depletion of one of the fundamental beams by two-photon absorption is observed.

Applied Physics Letters•Sep 1, 1977•35 citations

Resonant four‐wave mixing processes in xenon

Yun Mui Yiu, Keith Bonin, Thomas J. Mcilrath

Two‐photon resonantly enhanced four‐wave processes in xenon involving the intermediate states were utilized to generate coherent VUV radiation at several wavelengths between 125.9 nm and 101.8 nm. Maximum efficiencies of the order of 10−4 were achieved. The use of these processes for producing tunable VUV output with Xe is given and generation of tunable VUV using two‐photon resonances in other rare gases is discussed.

AIP conference proceedings•Jan 1, 1982•1 citation

TWO-PHOTON PUMPEL SIX-AND FOUR-WAVE MIXING AND STIMULATED RADIATION IN LITHIUM VAPOR

Zugeng Wang, 华东师范大学物理系,上海,200062

This paper reports the generation of the coherent and stimulated radiation in UV, visible and infrared regions by two-photon pumping. It includes the tunable coherent radiation around 1.03 μm generated by a special six-wave mixing process, the stimulated radiation at 812.6 nm generated by molecular two-photon dissociation or atomic cascade transition, coherent radiation at 323.3 nm and 670.8 nm generated by the four-wave mixings.

Acta Physica Sinica•Jan 1, 1990•0 citations

High-efficiency, energy-scalable, coherent 130-nm source by four-wave mixing in Hg vapor

C. H. Muller, Arlee V. Smith, Dennis D. Lowenthal +1 more

Coherent vacuum-ultraviolet (VUV) pulses with energy of 1.1 mJ, 2.2-nsec pulse length (2 MW cm−2 unfocused), and measured bandwidth ≤0.1 cm−1 have been achieved at 130 nm from four-wave mixing in Hg vapor. Conversion efficiencies of 5% have been demonstrated in a collimated beam geometry over 1-m interaction lengths. These high efficiencies are made possible by using two-photon-resonant sum-frequency mixing through the Hg 71S level. The experimental facility assembled to produce this efficient VUV source is described, and a comparison between experimental measurements and theory is provided.

Optics Letters•Aug 1, 1988•44 citations
Vacuum-ultra violet radiation is generated by 61S0-61D2 or 61S0-63D2 two photon resonant four-wave difference mixing (ω4=2ω1-ω3) in Hg vapor. VUV radiation is tunable when one of the input wave (ω3) is tuned, the tuning range is 184.9-187.5 nm. The mechanism of this frenquency conversion, for example, the two-photon and single-photon resonant enhancement and phase matching have been investigeted. The competing processes and saturation effect on conversion efficiency have been analyzed. Using the generated tunable VUV radiation, we have recorded the absorption spetrum of O2 in air.
Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A frequency-doubled dye laser tuned to two-photon resonance with the 6s6d(1)D(2) level near 280.3 nm produced output at 184.9 and 143.5 nm. A tunable krypton fluoride excimer laser tuned to two-photon resonance with the 6s10s (1)S(0) level near 248.7 nm produced output at 140.1, 130.7, 130.1, 125.9, and 125.0 nm. Approximately 1-microJ, 200-W pulses were observed at 143.5 and 125.9 nm.
Coherent vacuum-ultraviolet (VUV) pulses with energy of 1.1 mJ, 2.2-nsec pulse length (2 MW cm−2 unfocused), and measured bandwidth ≤0.1 cm−1 have been achieved at 130 nm from four-wave mixing in Hg vapor. Conversion efficiencies of 5% have been demonstrated in a collimated beam geometry over 1-m interaction lengths. These high efficiencies are made possible by using two-photon-resonant sum-frequency mixing through the Hg 71S level. The experimental facility assembled to produce this efficient VUV source is described, and a comparison between experimental measurements and theory is provided.