Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser & Optoelectronics Progress

Progress of Orthogonal Polarization Detection Technology in Pulsed Optically Pumped Atomic Clock

林锦达 Lin Jinda, 邓见辽 Deng Jianliao, 马易升 Ma Yisheng, 何慧娟 He Huijuan, 王育竹 Wang Yuzhu

Published Jan 1, 2013• 0 citations
Publisher
DOI
10.3788/lop50.080012

Related papers

Laser-noise-immune pulsed optically pumped atomic clock by means of differential detection

Xuejie Li, Yuhan Yan, Bowen Yang +4 more

Physical Review Applied•Sep 2, 2025•0 citations

Research on Atomic Phase Feedback in Pulsed Optically Pumped Atomic Clocks

Gongxun Dong, 林锦达 Lin Jinda, 张 松 Zhang Song +2 more

Acta Optica Sinica•Jan 1, 2017•1 citation

Frequency stability of a pulsed optically pumped atomic clock with narrow Ramsey linewidth

Haixiao Lin, Jianliao Deng, Jinda Lin +2 more

In general, the linewidth of the Ramsey central fringe (RCF) is equal to 1/(2T), where T is the Ramsey free-evolution time. We demonstrate that the RCF linewidth of a pulsed optically pumped (POP) atomic clock with orthogonal polarization detection based on the magneto-optical rotation effect can be narrowed down to 1/(4T). The Allan deviation of the POP atomic clock decreases from 2.4×10−13τ−1/2 to 1.4×10−13τ−1/2. This corresponds to an improvement in the frequency stability by about 60%. We also estimate the main noise sources that limit the short-term frequency stability of the POP atomic clock.

Applied Optics•Apr 12, 2018•14 citations

Pulsed optically pumped rubidium atomic clock with optical detection

I. H. Choi, Y.-H. Park, S. H. Lee +3 more

We describe the ongoing work on a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. In order to eliminate the light shifts and to increase the stability of vapor-cell atomic clock, pulsed optical pumping technique has been used. For simplicity, direct laser absorption signal is used for the detection of a clock transition.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

Improvement of short-term stability of pulsed optically pumped rubidium atomic clock

I. H. Choi, S. B. Lee, Taeg Yong Kwon +1 more

We present a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. The pulsed optical pumping technique can eliminate the light shifts and increase the stability of vapor-cell atomic clock. For simplicity, direct laser absorption signal is used for the detection of a clock transition. A frequency stability of about 2×10-11at 1s has been measured and short term stability is improved by reducing the pulse sequence time with a real time control system.

•Jun 1, 2010•1 citation

New methods for the production and detection of polarized atoms

Dimitris Sofikitis

•Jun 1, 2010•0 citations
In general, the linewidth of the Ramsey central fringe (RCF) is equal to 1/(2T), where T is the Ramsey free-evolution time. We demonstrate that the RCF linewidth of a pulsed optically pumped (POP) atomic clock with orthogonal polarization detection based on the magneto-optical rotation effect can be narrowed down to 1/(4T). The Allan deviation of the POP atomic clock decreases from 2.4×10−13τ−1/2 to 1.4×10−13τ−1/2. This corresponds to an improvement in the frequency stability by about 60%. We also estimate the main noise sources that limit the short-term frequency stability of the POP atomic clock.