Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Proportional-scanning-phase method to suppress the vibrational noise in nonisotope dual-atom-interferometer-based weak-equivalence-principle-test experiments

Xi Chen, Jiaqi Zhong, Hongwei Song, Lei Zhu, Jin Wang, Mingsheng Zhan

Published Aug 7, 2014• 25 citations
Publisher

Abstract

Vibrational noise is one of the most important noises that limits the performance of the nonisotopes atom-interferometers (AIs) -based weak-equivalence-principle (WEP) -test experiment. By analyzing the vibration-induced phases, we find that, although the induced phases are not completely common, their ratio is always a constant at every experimental data point, which is not fully utilized in the traditional elliptic curve-fitting method. From this point, we propose a strategy that can greatly suppress the vibration-induced phase noise by stabilizing the Raman laser frequencies at high precision and controlling the scanning-phase ratio. The noise rejection ratio can be as high as ${10}^{15}$ with arbitrary dual-species AIs. Our method provides a Lissajous curve, and the shape of the curve indicates the breakdown of the weak-equivalence-principle signal. Then we manage to derive an estimator for the differential phase of the Lissajous curve. This strategy could be helpful in extending the candidates of atomic species for high-precision AIs-based WEP-test experiments.

DOI
10.1103/physreva.90.023609

Related papers

Analysis and suppression of wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers

Jiangong Hu, Xi Chen, Jie Fang +4 more

The wave-front aberration of Raman beams induces phase noise in atom interferometers and thus limits the performance of atom interferometers. We theoretically analyze the wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers, and propose an expansion-rate-selection method to suppress the wave-front-aberration phase noise in both isotopic and nonisotopic atom interferometers. The suppression ratio is about 10 at the expense of half the number of atoms. The simulation based on appropriate experimental parameters shows that the wave-front aberration caused standard deviations to the E\"otv\"os coefficient in weak-equivalence-principle tests using $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ and $^{41}\mathrm{K}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ are $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ and $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$. Better results can be obtained by improving the wave-front quality and utilizing atom cloud with lower temperature. The analysis and suppression of wave-front-aberration phase noise will be useful for the design of high-precision atom interferometer--based weak-equivalence-principle tests both on ground and in space.

Physical Review A•Aug 21, 2017•19 citations

Correlative methods for dual-species quantum tests of the weak equivalence principle

B. Barrett, Laura Antoni‐Micollier, Laure Chichet +5 more

Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.

arXiv:1503.08423•New Journal of Physics•Aug 27, 2015•85 citations

Fringe-locking method for the weak equivalence principle test by simultaneous dual-species atom interferometers

Xiao‐Chun Duan, Xiao-Bing Deng, Dekai Mao +3 more

We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.

arXiv:1603.01321•Mar 4, 2016•0 citations

Moiré-Enabled Recursive Phase Unwrapping for Differential Atom Interferometry

Junjie Jiang, Sitong Yan, Jiaming Wei +5 more

Weak equivalence principle tests comparing different elements may be more sensitive to violations than those comparing isotopes. However, differences in effective wave vector complicate common-mode rejection of vibration noise. We propose a Moiré-enabled recursive phase unwrapping (MRPU) method for differential measurements with dual-species atom interferometers. The method exploits the moiré structure of the joint phase likelihood and temporal acceleration correlations to unwrap both phases and determine the relative acceleration. We implemented an $^{85}$Rb $\mathrm{D_1/D_2}$ line dual-scale-factor interferometer with an identical normalized transfer function and a large effective wave-vector difference to emulate different atomic species. Under $40\,\mathrm{rad}$ equivalent vibrational noise, this method achieved phase unwrapping over 5000 consecutive measurements, with a relative-acceleration Allan deviation of $1.47\times10^{-8}g$ at 997 shots. Numerical simulations under random vibrations and slow drifts show a $9.76 - 26.03\,\mathrm{dB}$ increase in the tolerable narrowband vibration amplitude. This method is promising for weak equivalence principle tests based on different atomic species, dark matter and dark energy detection, and high-dynamic-range atomic gravimetry.

physics.atom-phCross-listedarXiv:2611.25827•Nov 20, 2026•0 citations

Test of Equivalence Principle at 1 0 − 8 Level by a Dual-Species Double-Diffraction Raman Atom Interferometer

Lin Zhou, Shitong Long, Biao Tang +9 more

We report an improved test of the weak equivalence principle by using a simultaneous $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ dual-species atom interferometer. We propose and implement a four-wave double-diffraction Raman transition scheme for the interferometer, and demonstrate its ability in suppressing common-mode phase noise of Raman lasers after their frequencies and intensity ratios are optimized. The statistical uncertainty of the experimental data for E\"otv\"os parameter $\ensuremath{\eta}$ is $0.8\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$ at 3200 s. With various systematic errors corrected, the final value is $\ensuremath{\eta}=(2.8\ifmmode\pm\else\textpm\fi{}3.0)\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$. The major uncertainty is attributed to the Coriolis effect.

arXiv:1503.00401•Physical Review Letters•Jul 2, 2015•352 citations

Characterization of a simultaneous dual-species atom interferometer for a quantum test of the weak equivalence principle

Alexis Bonnin, Nassim Zahzam, Yannick Bidel +1 more

We present here the performance of a simultaneous dual-species matter-wave accelerometer for measuring the differential acceleration between two different atomic species ($^{87}\mathrm{Rb}$ and $^{85}\mathrm{Rb}$). We study the expression and the extraction of the differential phase from the interferometer output. The differential accelerometer reaches a short-term sensitivity of $1.23\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}g/\sqrt{\mathrm{Hz}}$ limited by the detection noise and a resolution of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}g$ after 11 000 s, a very high sensitivity using a dual-species atom interferometer. Thanks to the simultaneous measurement, such resolution levels can still be achieved even with vibration levels up to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}g$, corresponding to a common-mode vibration noise rejection ratio of 94 dB (rejection factor of 50 000). These results prove the ability of such atom sensors for realizing a quantum-based test of the weak equivalence principle at a level of $\ensuremath{\eta}\ensuremath{\sim}{10}^{\ensuremath{-}9}$ even with high vibration levels and a compact sensor.

arXiv:1506.06535•Physical Review A•Aug 18, 2015•64 citations
Vibrational noise is one of the most important noises that limits the performance of the nonisotopes atom-interferometers (AIs) -based weak-equivalence-principle (WEP) -test experiment. By analyzing the vibration-induced phases, we find that, although the induced phases are not completely common, their ratio is always a constant at every experimental data point, which is not fully utilized in the traditional elliptic curve-fitting method. From this point, we propose a strategy that can greatly suppress the vibration-induced phase noise by stabilizing the Raman laser frequencies at high precision and controlling the scanning-phase ratio. The noise rejection ratio can be as high as 1015{10}^{15}1015 with arbitrary dual-species AIs. Our method provides a Lissajous curve, and the shape of the curve indicates the breakdown of the weak-equivalence-principle signal. Then we manage to derive an estimator for the differential phase of the Lissajous curve. This strategy could be helpful in extending the candidates of atomic species for high-precision AIs-based WEP-test experiments.
The wave-front aberration of Raman beams induces phase noise in atom interferometers and thus limits the performance of atom interferometers. We theoretically analyze the wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers, and propose an expansion-rate-selection method to suppress the wave-front-aberration phase noise in both isotopic and nonisotopic atom interferometers. The suppression ratio is about 10 at the expense of half the number of atoms. The simulation based on appropriate experimental parameters shows that the wave-front aberration caused standard deviations to the E\"otv\"os coefficient in weak-equivalence-principle tests using $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ and $^{41}\mathrm{K}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ are $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ and $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$. Better results can be obtained by improving the wave-front quality and utilizing atom cloud with lower temperature. The analysis and suppression of wave-front-aberration phase noise will be useful for the design of high-precision atom interferometer--based weak-equivalence-principle tests both on ground and in space.
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.
We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.
Weak equivalence principle tests comparing different elements may be more sensitive to violations than those comparing isotopes. However, differences in effective wave vector complicate common-mode rejection of vibration noise. We propose a Moiré-enabled recursive phase unwrapping (MRPU) method for differential measurements with dual-species atom interferometers. The method exploits the moiré structure of the joint phase likelihood and temporal acceleration correlations to unwrap both phases and determine the relative acceleration. We implemented an 85^{85}85Rb D1/D2\mathrm{D_1/D_2}D1​/D2​ line dual-scale-factor interferometer with an identical normalized transfer function and a large effective wave-vector difference to emulate different atomic species. Under 40 rad40\,\mathrm{rad}40rad equivalent vibrational noise, this method achieved phase unwrapping over 5000 consecutive measurements, with a relative-acceleration Allan deviation of 1.47×10−8g1.47\times10^{-8}g1.47×10−8g at 997 shots. Numerical simulations under random vibrations and slow drifts show a 9.76−26.03 dB9.76 - 26.03\,\mathrm{dB}9.76−26.03dB increase in the tolerable narrowband vibration amplitude. This method is promising for weak equivalence principle tests based on different atomic species, dark matter and dark energy detection, and high-dynamic-range atomic gravimetry.
We report an improved test of the weak equivalence principle by using a simultaneous $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ dual-species atom interferometer. We propose and implement a four-wave double-diffraction Raman transition scheme for the interferometer, and demonstrate its ability in suppressing common-mode phase noise of Raman lasers after their frequencies and intensity ratios are optimized. The statistical uncertainty of the experimental data for E\"otv\"os parameter $\ensuremath{\eta}$ is $0.8\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$ at 3200 s. With various systematic errors corrected, the final value is $\ensuremath{\eta}=(2.8\ifmmode\pm\else\textpm\fi{}3.0)\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$. The major uncertainty is attributed to the Coriolis effect.
We present here the performance of a simultaneous dual-species matter-wave accelerometer for measuring the differential acceleration between two different atomic species (87Rb^{87}\mathrm{Rb}87Rb and 85Rb^{85}\mathrm{Rb}85Rb). We study the expression and the extraction of the differential phase from the interferometer output. The differential accelerometer reaches a short-term sensitivity of $1.23\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}g/\sqrt{\mathrm{Hz}}$ limited by the detection noise and a resolution of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}g$ after 11 000 s, a very high sensitivity using a dual-species atom interferometer. Thanks to the simultaneous measurement, such resolution levels can still be achieved even with vibration levels up to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}g$, corresponding to a common-mode vibration noise rejection ratio of 94 dB (rejection factor of 50 000). These results prove the ability of such atom sensors for realizing a quantum-based test of the weak equivalence principle at a level of $\ensuremath{\eta}\ensuremath{\sim}{10}^{\ensuremath{-}9}$ even with high vibration levels and a compact sensor.