arXiv:2611.25827
Moiré-Enabled Recursive Phase Unwrapping for Differential Atom Interferometry
Junjie Jiang, Sitong Yan, Jiaming Wei, Chuan He, Xi Chen, Lin Zhou, Jin Wang, Ming-Sheng Zhan
Abstract
Weak equivalence principle tests comparing different elements may be more sensitive to violations than those comparing isotopes. However, differences in effective wave vector complicate common-mode rejection of vibration noise. We propose a Moiré-enabled recursive phase unwrapping (MRPU) method for differential measurements with dual-species atom interferometers. The method exploits the moiré structure of the joint phase likelihood and temporal acceleration correlations to unwrap both phases and determine the relative acceleration. We implemented an $^{85}$Rb $\mathrm{D_1/D_2}$ line dual-scale-factor interferometer with an identical normalized transfer function and a large effective wave-vector difference to emulate different atomic species. Under $40\,\mathrm{rad}$ equivalent vibrational noise, this method achieved phase unwrapping over 5000 consecutive measurements, with a relative-acceleration Allan deviation of $1.47\times10^{-8}g$ at 997 shots. Numerical simulations under random vibrations and slow drifts show a $9.76 - 26.03\,\mathrm{dB}$ increase in the tolerable narrowband vibration amplitude. This method is promising for weak equivalence principle tests based on different atomic species, dark matter and dark energy detection, and high-dynamic-range atomic gravimetry.
AI Summary
Dual-element atom interferometers have unequal effective wave vectors, so common vibration noise does not cancel directly when measured phases wrap modulo $2\pi$. This paper proposes moiré-enabled recursive phase unwrapping (MRPU), combining the joint two-phase likelihood with a Bayesian prediction based on temporal acceleration correlations. The wave-vector difference supplies a coarse moiré acceleration scale; recursion helps select among fine-scale likelihood peaks. Identical pulse timing and matched Rabi frequencies preserve matched normalized vibration responses without an auxiliary accelerometer. The experimental demonstration uses synchronous $^{85}$Rb interferometers on the $D_1$ and $D_2$ lines, with $T=50\,\mathrm{ms}$ and a $1.9\%$ wave-vector difference, emulating the mismatch of Rb–K interferometers. Proportional Raman-chirp scans impose vibration-equivalent phase excursions of approximately $40\,\mathrm{rad}$. MRPU tracks 5000 consecutive measurements, yielding a differential-phase standard deviation of $0.184\,\mathrm{rad}$ and a relative-acceleration Allan deviation of $1.47\times10^{-8}g$ at 997 shots. Simulations with narrowband Gaussian vibration, quality factor $Q=10$, and independent $0.02\,\mathrm{rad}$ phase noise show a $9.76$–$26.03\,\mathrm{dB}$ increase in tolerable vibration amplitude at a 95% unwrapping-success threshold relative to remaining within the unwrapped measurement range. Example success rates are approximately 94%, including with slow drift. The experiment uses one isotope and a controlled chirp scan rather than distinct elements under random mechanical vibration. The scan amplitude is limited to avoid Raman detuning and signal loss; detuning can increase readout noise. The method relies on temporal acceleration correlations, and its simulated random-vibration unwrapping is not error-free.
Error found: The experimental demonstration establishes unwrapping for a controlled, periodic vibration-equivalent chirp trajectory; performance under random mechanical vibration is supported only by simulations. The Bayesian transition kernel and initialization are not quantitatively specified, preventing reproduction of the reported unwrapping performance or assessment of its dependence on assumed temporal correlations.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.