Moiré-Enabled Recursive Phase Unwrapping for Differential Atom Interferometry

Junjie Jiang, Sitong Yan, Jiaming Wei, Chuan He, Xi Chen, Lin Zhou, Jin Wang, Ming-Sheng Zhan

physics.atom-phquant-phSubmitted Nov 19, 2026• Announced Nov 20, 2026• 0 citations
arXivHTMLPDF

Abstract

Weak equivalence principle tests comparing different elements may be more sensitive to violations than those comparing isotopes. However, differences in effective wave vector complicate common-mode rejection of vibration noise. We propose a Moiré-enabled recursive phase unwrapping (MRPU) method for differential measurements with dual-species atom interferometers. The method exploits the moiré structure of the joint phase likelihood and temporal acceleration correlations to unwrap both phases and determine the relative acceleration. We implemented an $^{85}$Rb $\mathrm{D_1/D_2}$ line dual-scale-factor interferometer with an identical normalized transfer function and a large effective wave-vector difference to emulate different atomic species. Under $40\,\mathrm{rad}$ equivalent vibrational noise, this method achieved phase unwrapping over 5000 consecutive measurements, with a relative-acceleration Allan deviation of $1.47\times10^{-8}g$ at 997 shots. Numerical simulations under random vibrations and slow drifts show a $9.76 - 26.03\,\mathrm{dB}$ increase in the tolerable narrowband vibration amplitude. This method is promising for weak equivalence principle tests based on different atomic species, dark matter and dark energy detection, and high-dynamic-range atomic gravimetry.

AI Summary

Dual-element atom interferometers have unequal effective wave vectors, so common vibration noise does not cancel directly when measured phases wrap modulo $2\pi$. This paper proposes moiré-enabled recursive phase unwrapping (MRPU), combining the joint two-phase likelihood with a Bayesian prediction based on temporal acceleration correlations. The wave-vector difference supplies a coarse moiré acceleration scale; recursion helps select among fine-scale likelihood peaks. Identical pulse timing and matched Rabi frequencies preserve matched normalized vibration responses without an auxiliary accelerometer. The experimental demonstration uses synchronous $^{85}$Rb interferometers on the $D_1$ and $D_2$ lines, with $T=50\,\mathrm{ms}$ and a $1.9\%$ wave-vector difference, emulating the mismatch of Rb–K interferometers. Proportional Raman-chirp scans impose vibration-equivalent phase excursions of approximately $40\,\mathrm{rad}$. MRPU tracks 5000 consecutive measurements, yielding a differential-phase standard deviation of $0.184\,\mathrm{rad}$ and a relative-acceleration Allan deviation of $1.47\times10^{-8}g$ at 997 shots. Simulations with narrowband Gaussian vibration, quality factor $Q=10$, and independent $0.02\,\mathrm{rad}$ phase noise show a $9.76$–$26.03\,\mathrm{dB}$ increase in tolerable vibration amplitude at a 95% unwrapping-success threshold relative to remaining within the unwrapped measurement range. Example success rates are approximately 94%, including with slow drift. The experiment uses one isotope and a controlled chirp scan rather than distinct elements under random mechanical vibration. The scan amplitude is limited to avoid Raman detuning and signal loss; detuning can increase readout noise. The method relies on temporal acceleration correlations, and its simulated random-vibration unwrapping is not error-free.

No sign of AI-generated textMissing comparisonStrong assumptionsOverclaims

Error found: The experimental demonstration establishes unwrapping for a controlled, periodic vibration-equivalent chirp trajectory; performance under random mechanical vibration is supported only by simulations. The Bayesian transition kernel and initialization are not quantitatively specified, preventing reproduction of the reported unwrapping performance or assessment of its dependence on assumed temporal correlations.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Correlative methods for dual-species quantum tests of the weak equivalence principle

B. Barrett, Laura Antoni‐Micollier, Laure Chichet +5 more

Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.

arXiv:1503.08423•New Journal of Physics•Aug 27, 2015•85 citations

Characterization of a simultaneous dual-species atom interferometer for a quantum test of the weak equivalence principle

Alexis Bonnin, Nassim Zahzam, Yannick Bidel +1 more

We present here the performance of a simultaneous dual-species matter-wave accelerometer for measuring the differential acceleration between two different atomic species ($^{87}\mathrm{Rb}$ and $^{85}\mathrm{Rb}$). We study the expression and the extraction of the differential phase from the interferometer output. The differential accelerometer reaches a short-term sensitivity of $1.23\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}g/\sqrt{\mathrm{Hz}}$ limited by the detection noise and a resolution of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}g$ after 11 000 s, a very high sensitivity using a dual-species atom interferometer. Thanks to the simultaneous measurement, such resolution levels can still be achieved even with vibration levels up to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}g$, corresponding to a common-mode vibration noise rejection ratio of 94 dB (rejection factor of 50 000). These results prove the ability of such atom sensors for realizing a quantum-based test of the weak equivalence principle at a level of $\ensuremath{\eta}\ensuremath{\sim}{10}^{\ensuremath{-}9}$ even with high vibration levels and a compact sensor.

arXiv:1506.06535•Physical Review A•Aug 18, 2015•64 citations

Simultaneous dual-species matter-wave accelerometer

Alexis Bonnin, Nassim Zahzam, Yannick Bidel +1 more

We report the realization of a matter-wave interferometer based on Raman transitions which simultaneously interrogates two different atomic species (${}^{87}$Rb and ${}^{85}$Rb). The simultaneous aspect of our experiment presents encouraging preliminary results for future dual-species atom interferometry projects and seems very promising by taking advantage of a differential acceleration measurement. Indeed, the resolution of our differential accelerometer remains lower than $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ even with vibration levels up to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ thanks to common-mode vibration noise rejection. An atom-based test of the weak equivalence principle has also been carried out leading to a differential free fall measurement between both isotopes of $\ensuremath{\Delta}g/g=(1.2\ifmmode\pm\else\textpm\fi{}3.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$.

arXiv:1307.2734•Physical Review A•Oct 11, 2013•191 citations

Fringe-locking method for the weak equivalence principle test by simultaneous dual-species atom interferometers

Xiao‐Chun Duan, Xiao-Bing Deng, Dekai Mao +3 more

We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.

arXiv:1603.01321•Mar 4, 2016•0 citations

Proportional-scanning-phase method to suppress the vibrational noise in nonisotope dual-atom-interferometer-based weak-equivalence-principle-test experiments

Xi Chen, Jiaqi Zhong, Hongwei Song +3 more

Vibrational noise is one of the most important noises that limits the performance of the nonisotopes atom-interferometers (AIs) -based weak-equivalence-principle (WEP) -test experiment. By analyzing the vibration-induced phases, we find that, although the induced phases are not completely common, their ratio is always a constant at every experimental data point, which is not fully utilized in the traditional elliptic curve-fitting method. From this point, we propose a strategy that can greatly suppress the vibration-induced phase noise by stabilizing the Raman laser frequencies at high precision and controlling the scanning-phase ratio. The noise rejection ratio can be as high as ${10}^{15}$ with arbitrary dual-species AIs. Our method provides a Lissajous curve, and the shape of the curve indicates the breakdown of the weak-equivalence-principle signal. Then we manage to derive an estimator for the differential phase of the Lissajous curve. This strategy could be helpful in extending the candidates of atomic species for high-precision AIs-based WEP-test experiments.

Physical Review A•Aug 7, 2014•25 citations

Analysis and suppression of wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers

Jiangong Hu, Xi Chen, Jie Fang +4 more

The wave-front aberration of Raman beams induces phase noise in atom interferometers and thus limits the performance of atom interferometers. We theoretically analyze the wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers, and propose an expansion-rate-selection method to suppress the wave-front-aberration phase noise in both isotopic and nonisotopic atom interferometers. The suppression ratio is about 10 at the expense of half the number of atoms. The simulation based on appropriate experimental parameters shows that the wave-front aberration caused standard deviations to the E\"otv\"os coefficient in weak-equivalence-principle tests using $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ and $^{41}\mathrm{K}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ are $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ and $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$. Better results can be obtained by improving the wave-front quality and utilizing atom cloud with lower temperature. The analysis and suppression of wave-front-aberration phase noise will be useful for the design of high-precision atom interferometer--based weak-equivalence-principle tests both on ground and in space.

Physical Review A•Aug 21, 2017•19 citations
Weak equivalence principle tests comparing different elements may be more sensitive to violations than those comparing isotopes. However, differences in effective wave vector complicate common-mode rejection of vibration noise. We propose a Moiré-enabled recursive phase unwrapping (MRPU) method for differential measurements with dual-species atom interferometers. The method exploits the moiré structure of the joint phase likelihood and temporal acceleration correlations to unwrap both phases and determine the relative acceleration. We implemented an 85^{85}85Rb D1/D2\mathrm{D_1/D_2}D1​/D2​ line dual-scale-factor interferometer with an identical normalized transfer function and a large effective wave-vector difference to emulate different atomic species. Under 40 rad40\,\mathrm{rad}40rad equivalent vibrational noise, this method achieved phase unwrapping over 5000 consecutive measurements, with a relative-acceleration Allan deviation of 1.47×10−8g1.47\times10^{-8}g1.47×10−8g at 997 shots. Numerical simulations under random vibrations and slow drifts show a 9.76−26.03 dB9.76 - 26.03\,\mathrm{dB}9.76−26.03dB increase in the tolerable narrowband vibration amplitude. This method is promising for weak equivalence principle tests based on different atomic species, dark matter and dark energy detection, and high-dynamic-range atomic gravimetry.
Dual-element atom interferometers have unequal effective wave vectors, so common vibration noise does not cancel directly when measured phases wrap modulo 2π2\pi2π. This paper proposes moiré-enabled recursive phase unwrapping (MRPU), combining the joint two-phase likelihood with a Bayesian prediction based on temporal acceleration correlations. The wave-vector difference supplies a coarse moiré acceleration scale; recursion helps select among fine-scale likelihood peaks. Identical pulse timing and matched Rabi frequencies preserve matched normalized vibration responses without an auxiliary accelerometer.
The experimental demonstration uses synchronous 85^{85}85Rb interferometers on the D1D_1D1​ and D2D_2D2​ lines, with T=50 msT=50\,\mathrm{ms}T=50ms and a 1.9%1.9\%1.9% wave-vector difference, emulating the mismatch of Rb–K interferometers. Proportional Raman-chirp scans impose vibration-equivalent phase excursions of approximately 40 rad40\,\mathrm{rad}40rad. MRPU tracks 5000 consecutive measurements, yielding a differential-phase standard deviation of 0.184 rad0.184\,\mathrm{rad}0.184rad and a relative-acceleration Allan deviation of 1.47×10−8g1.47\times10^{-8}g1.47×10−8g at 997 shots.
Simulations with narrowband Gaussian vibration, quality factor Q=10Q=10Q=10, and independent 0.02 rad0.02\,\mathrm{rad}0.02rad phase noise show a 9.769.769.76–26.03 dB26.03\,\mathrm{dB}26.03dB increase in tolerable vibration amplitude at a 95% unwrapping-success threshold relative to remaining within the unwrapped measurement range. Example success rates are approximately 94%, including with slow drift.
The experiment uses one isotope and a controlled chirp scan rather than distinct elements under random mechanical vibration. The scan amplitude is limited to avoid Raman detuning and signal loss; detuning can increase readout noise. The method relies on temporal acceleration correlations, and its simulated random-vibration unwrapping is not error-free.
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.
We present here the performance of a simultaneous dual-species matter-wave accelerometer for measuring the differential acceleration between two different atomic species (87Rb^{87}\mathrm{Rb}87Rb and 85Rb^{85}\mathrm{Rb}85Rb). We study the expression and the extraction of the differential phase from the interferometer output. The differential accelerometer reaches a short-term sensitivity of $1.23\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}g/\sqrt{\mathrm{Hz}}$ limited by the detection noise and a resolution of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}g$ after 11 000 s, a very high sensitivity using a dual-species atom interferometer. Thanks to the simultaneous measurement, such resolution levels can still be achieved even with vibration levels up to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}g$, corresponding to a common-mode vibration noise rejection ratio of 94 dB (rejection factor of 50 000). These results prove the ability of such atom sensors for realizing a quantum-based test of the weak equivalence principle at a level of $\ensuremath{\eta}\ensuremath{\sim}{10}^{\ensuremath{-}9}$ even with high vibration levels and a compact sensor.
We report the realization of a matter-wave interferometer based on Raman transitions which simultaneously interrogates two different atomic species (87{}^{87}87Rb and 85{}^{85}85Rb). The simultaneous aspect of our experiment presents encouraging preliminary results for future dual-species atom interferometry projects and seems very promising by taking advantage of a differential acceleration measurement. Indeed, the resolution of our differential accelerometer remains lower than $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ even with vibration levels up to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ thanks to common-mode vibration noise rejection. An atom-based test of the weak equivalence principle has also been carried out leading to a differential free fall measurement between both isotopes of $\ensuremath{\Delta}g/g=(1.2\ifmmode\pm\else\textpm\fi{}3.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$.
We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.
Vibrational noise is one of the most important noises that limits the performance of the nonisotopes atom-interferometers (AIs) -based weak-equivalence-principle (WEP) -test experiment. By analyzing the vibration-induced phases, we find that, although the induced phases are not completely common, their ratio is always a constant at every experimental data point, which is not fully utilized in the traditional elliptic curve-fitting method. From this point, we propose a strategy that can greatly suppress the vibration-induced phase noise by stabilizing the Raman laser frequencies at high precision and controlling the scanning-phase ratio. The noise rejection ratio can be as high as 1015{10}^{15}1015 with arbitrary dual-species AIs. Our method provides a Lissajous curve, and the shape of the curve indicates the breakdown of the weak-equivalence-principle signal. Then we manage to derive an estimator for the differential phase of the Lissajous curve. This strategy could be helpful in extending the candidates of atomic species for high-precision AIs-based WEP-test experiments.
The wave-front aberration of Raman beams induces phase noise in atom interferometers and thus limits the performance of atom interferometers. We theoretically analyze the wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers, and propose an expansion-rate-selection method to suppress the wave-front-aberration phase noise in both isotopic and nonisotopic atom interferometers. The suppression ratio is about 10 at the expense of half the number of atoms. The simulation based on appropriate experimental parameters shows that the wave-front aberration caused standard deviations to the E\"otv\"os coefficient in weak-equivalence-principle tests using $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ and $^{41}\mathrm{K}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ are $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ and $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$. Better results can be obtained by improving the wave-front quality and utilizing atom cloud with lower temperature. The analysis and suppression of wave-front-aberration phase noise will be useful for the design of high-precision atom interferometer--based weak-equivalence-principle tests both on ground and in space.