Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Investigation of Ramsey spectroscopy in a lin-par-lin Ramsey coherent population trapping clock with dispersion detection

Xiaolin Sun, Jianwei Zhang, Pengfei Cheng, Chi Xu, Libo Zhao, L. J. Wang

Published Feb 23, 2016• 15 citations
Publisher

Abstract

Rb clock using a dispersion detection technique has a promising performance. We theoretically and experimentally investigate the signal-to-noise ratio of the Ramsey spectrum signal by varying the relative angle of the polarizer and analyzer as well as the magnetic field. Based on the experimental results, the optimized relative angle and magnetic field are determined. This kind of atomic clock is attractive for the development of compact, high performance vapor clock based on CPT.

DOI
10.1364/oe.24.004532

Related papers

Ramsey-coherent population trapping Cs atomic clock based on lin∥lin optical pumping with dispersion detection*

Pengfei Cheng, Jianwei Zhang, Lijun Wang

A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.

Chinese Physics B•Jul 1, 2019•9 citations

Study of lin||lin CPT for application in vapour cell atomic clocks

Evelina Breschi, Georgy A. Kazakov, Boris G. Matisov +1 more

We evaluate the use of Coherent Population Trapping (CPT) excited with parallely polarized laser fields in vapour cell atomic clocks. We study the resonance shape, the discriminator slope and signal-to-noise ratio as a function of relevant parameters such as the laser frequency detuning and the applied magnetic field. We show that a stability of $6 \cdot 10^{-12}$ $τ^{-1/2}$ may be reached in a compact system using a modulated VCSEL.

arXiv:0710.0778•Oct 3, 2007•0 citations

Ramsey Spectroscopy of CPT Resonances on the D1 Line of Alkali Metal Atoms in Miniature Cells in the Field of Counterpropagating Waves with Opposite Circular Polarizations

Valeriy I. Yudin, M. Yu. Basalaev, Daba A. Radnatarov +4 more

In this study, the Ramsey spectroscopy of coherent population trapping resonances excited on the D1 line of alkali metal atoms in miniature vapor cells has been studied theoretically and experimentally. The configuration of the field produced by two counterpropagating waves with opposite circular polarizations has been considered. A counterpropagating wave is formed as a result of reflection from a partially transmitting output mirror, while the signal from the initial wave transmitted through the mirror is detected. It is shown that such a scheme is characterized by the optimal mirror reflection coefficient, for which the short-term stability can be substantially improved relative to the standard scheme without the counterpropagating wave. The three-fold improvement of the short-term stability of the atomic clock based on the coherent population trapping resonance in a vapor cell with 87Rb atoms has been demonstrated experimentally.

Journal of Experimental and Theoretical Physics Letters•Oct 1, 2024•0 citations

A coherent population trapping Cs vapor cell atomic clock based on push-pull optical pumping

Moustafa Abdel Hafiz, Rodolphe Boudot

This article reports on the characterization of a compact coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique. This method allows to detect high-contrast CPT resonances on the 0-0 magnetic-field insensitive clock transition. The clock short-term fractional frequency stability is measured to be 3×10−13 τ−1/2 up to 100 s averaging time, in correct agreement with the signal-to-noise ratio limit. These results are among the best performances ever reported for a CPT-based clock. The noise budget is detailed. A preliminary study is reported to evaluate limitations to the clock mid-term frequency stability. The clock performances are found to be presently mainly limited in the mid-term by laser power effects.

Journal of Applied Physics•Sep 28, 2015•49 citations

Experimental and theoretical comparison of different optical excitation schemes for a compact coherent population trapping Rb vapor clock

Zachary Warren, M. S. Shahriar, Renu Tripathi +1 more

Abstract We have investigated, theoretically as well as experimentally, the relative merits and demerits of using three different optical configurations for a compact coherent population trapping (CPT) vapor clock using 87 Rb. These correspond to the following choices of polarizations for the two Raman beams: lin ∥ lin , ( σ , σ ), and push–pull optical pumping (PPOP), applied on the D1 manifold. We have used a multi-level atomic model to study the dependence of the CPT spectrum on axial as well as transverse magnetic fields for these three schemes. Corresponding experimental studies have been performed using a laboratory scale CPT clock employing a two cm long, isotopically pure rubidium cell, loaded with a buffer gas. We observed a CPT contrast close to 20% with a sub-kilohertz linewidth by adopting the PPOP scheme. We discuss the strengths and weaknesses of each of the three optical excitation schemes, and present frequency-stability measurement data for the prototype clock.

Metrologia•May 12, 2017•29 citations

Performance of a prototype atomic clock based on lin‖lin coherent population trapping resonances in Rb atomic vapor

Eugeniy E. Mikhailov, Travis Horrom, Nathan Belcher +1 more

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.

arXiv:0910.5881•Journal of the Optical Society of America B•Feb 3, 2010•53 citations
Rb clock using a dispersion detection technique has a promising performance. We theoretically and experimentally investigate the signal-to-noise ratio of the Ramsey spectrum signal by varying the relative angle of the polarizer and analyzer as well as the magnetic field. Based on the experimental results, the optimized relative angle and magnetic field are determined. This kind of atomic clock is attractive for the development of compact, high performance vapor clock based on CPT.
A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.
We evaluate the use of Coherent Population Trapping (CPT) excited with parallely polarized laser fields in vapour cell atomic clocks. We study the resonance shape, the discriminator slope and signal-to-noise ratio as a function of relevant parameters such as the laser frequency detuning and the applied magnetic field. We show that a stability of 6⋅10−126 \cdot 10^{-12}6⋅10−12 τ−1/2τ^{-1/2}τ−1/2 may be reached in a compact system using a modulated VCSEL.
In this study, the Ramsey spectroscopy of coherent population trapping resonances excited on the D1 line of alkali metal atoms in miniature vapor cells has been studied theoretically and experimentally. The configuration of the field produced by two counterpropagating waves with opposite circular polarizations has been considered. A counterpropagating wave is formed as a result of reflection from a partially transmitting output mirror, while the signal from the initial wave transmitted through the mirror is detected. It is shown that such a scheme is characterized by the optimal mirror reflection coefficient, for which the short-term stability can be substantially improved relative to the standard scheme without the counterpropagating wave. The three-fold improvement of the short-term stability of the atomic clock based on the coherent population trapping resonance in a vapor cell with 87Rb atoms has been demonstrated experimentally.
This article reports on the characterization of a compact coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique. This method allows to detect high-contrast CPT resonances on the 0-0 magnetic-field insensitive clock transition. The clock short-term fractional frequency stability is measured to be 3×10−13 τ−1/2 up to 100 s averaging time, in correct agreement with the signal-to-noise ratio limit. These results are among the best performances ever reported for a CPT-based clock. The noise budget is detailed. A preliminary study is reported to evaluate limitations to the clock mid-term frequency stability. The clock performances are found to be presently mainly limited in the mid-term by laser power effects.
Abstract We have investigated, theoretically as well as experimentally, the relative merits and demerits of using three different optical configurations for a compact coherent population trapping (CPT) vapor clock using 87 Rb. These correspond to the following choices of polarizations for the two Raman beams: lin ∥ lin , ( σ , σ ), and push–pull optical pumping (PPOP), applied on the D1 manifold. We have used a multi-level atomic model to study the dependence of the CPT spectrum on axial as well as transverse magnetic fields for these three schemes. Corresponding experimental studies have been performed using a laboratory scale CPT clock employing a two cm long, isotopically pure rubidium cell, loaded with a buffer gas. We observed a CPT contrast close to 20% with a sub-kilohertz linewidth by adopting the PPOP scheme. We discuss the strengths and weaknesses of each of the three optical excitation schemes, and present frequency-stability measurement data for the prototype clock.
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.