Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

A compact, high-performance all optical atomic clock based on telecom lasers

John H. Burke, N. Lemke, Gretchen R. Phelps, Kyle W. Martin

Published Mar 7, 2016• 6 citations
Publisher

Abstract

We discuss an optical atomic clock based on a two-photon transition at 778 nm in rubidium. In particular, we discuss the fundamental limitations to the short-term stability of a system based on a commercial C-band telecom laser as opposed to a near infrared laser. We show that this system is fundamentally capable of besting a hydrogen MASER in frequency stability and size.

DOI
10.1117/12.2220212

Related papers

Compact Optical Clock with 5×10 −13 Instability at 1 s

Gretchen R. Phelps, N. Lemke, Christopher Erickson +2 more

We present a compact optical atomic clock design based on a two-photon transition at 778 nm in rubidium that is capable of a frequency instability of 5×10−13 at 1 s. The simple architecture occupies less than 30 L volume and currently uses commercial off-the-shelf components making this system an attractive, appealing, and competitive candidate to meet GPS-III spacecraft frequency stability requirements. Copyright © 2018 Institute of Navigation.

NAVIGATION Journal of the Institute of Navigation•Mar 1, 2018•19 citations

Compact two-photon optical clock with a long-term stability of 8.1 × 10−15 without linear drift removal

Chen Feng, Xinrui Luo, Ji’an Duan +5 more

In this work, we stabilize a 1556.2 nm fiber laser to the 5S1/2 → 5D5/2 two-photon transition in 87Rb in a carefully designed compact physics package. A commercial fiber frequency comb divides the optical frequency into 200 MHz microwave output, which demonstrates a fractional frequency stability of 2.2 × 10-13 at τ = 1 s and 8.1 × 10-15 at τ = 4000 s, without linear drift removal. We analyze the systematic effect on the short-term and long-term stabilities in detail. The short-term and long-term stabilities are limited by shot noise and ac Stark shift, respectively. The rubidium two-photon optical clock is a promising candidate for the next-generation space-borne atomic clock.

Review of Scientific Instruments•Dec 1, 2025•3 citations

High-performance, compact optical standard

Zachary L. Newman, Vincent N. Maurice, Connor D. Fredrick +6 more

We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8 × 10 − 13 τ − 1 / 2 for times less than 100 s and a flicker noise floor of 1 × 10 − 14 out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the ac Stark shift. The retrace was measured to 5.7 × 10 − 13 after 30 h of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.

arXiv:2105.00610•Optics Letters•Sep 15, 2021•97 citations

Compact 780-nm Rb optical clock

Zhendong Chen, Tianyu Liu, Ruoao Yang +9 more

We demonstrate a compact 780-nm rubidium optical clock, comprising an optical-frequency standard and an optical-frequency comb, with a total optical volume of 11.6 liters. Unlike the 778-nm rubidium atomic clocks based on two-photon transitions, the laser frequency in our system was stabilized to the hyperfine transition of ${}^{87}\mathrm{Rb}$ ${5}^{2}{\mathrm{S}}_{1/2}$ (F = 2) \ensuremath{\rightarrow} ${5}^{2}{\mathrm{P}}_{3/2}$ (F\ensuremath{'} = 3) using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides higher signal-to-noise ratio and sensitivity. After correcting for systematic perturbations, the absolute frequency was measured to be 384 228 115 200.7(2.7) kHz. A nearly 300-MHz microwave signal, whose phase exactly tracked that of the optical-frequency standard, was generated via the optical-frequency comb, yielding a frequency instability of 1.91 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}13}$ at 1 s and 5.29 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}14}$ at 1000 s in the electronic domain. The reproducibility was measured to be 3.66 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ by comparing results from four independent daily measurements, each conducted following a complete system shutdown and restart. This is among the most precise frequency stabilization results for the first-excited-state transition of alkali metal atoms to date, and represents an optical clock based on this transition. This work offers a promising approach for the development of portable optical clocks.

arXiv:2501.01826•Physical Review Applied•Jan 2, 2026•6 citations

An optical atomic clock using 4 D J states of rubidium

Alisher Duspayev, C Owens, Bineet Dash +1 more

We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.

arXiv:2406.09352•Quantum Science and Technology•Sep 17, 2024•8 citations

Short-term stability of a microcell optical reference based on the Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

arXiv:2407.00841•Journal of the Optical Society of America B•Dec 19, 2024•18 citations
We discuss an optical atomic clock based on a two-photon transition at 778 nm in rubidium. In particular, we discuss the fundamental limitations to the short-term stability of a system based on a commercial C-band telecom laser as opposed to a near infrared laser. We show that this system is fundamentally capable of besting a hydrogen MASER in frequency stability and size.
In this work, we stabilize a 1556.2 nm fiber laser to the 5S1/2 → 5D5/2 two-photon transition in 87Rb in a carefully designed compact physics package. A commercial fiber frequency comb divides the optical frequency into 200 MHz microwave output, which demonstrates a fractional frequency stability of 2.2 × 10-13 at τ = 1 s and 8.1 × 10-15 at τ = 4000 s, without linear drift removal. We analyze the systematic effect on the short-term and long-term stabilities in detail. The short-term and long-term stabilities are limited by shot noise and ac Stark shift, respectively. The rubidium two-photon optical clock is a promising candidate for the next-generation space-borne atomic clock.
We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8 × 10 − 13 τ − 1 / 2 for times less than 100 s and a flicker noise floor of 1 × 10 − 14 out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the ac Stark shift. The retrace was measured to 5.7 × 10 − 13 after 30 h of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.
We demonstrate a compact 780-nm rubidium optical clock, comprising an optical-frequency standard and an optical-frequency comb, with a total optical volume of 11.6 liters. Unlike the 778-nm rubidium atomic clocks based on two-photon transitions, the laser frequency in our system was stabilized to the hyperfine transition of 87Rb{}^{87}\mathrm{Rb}87Rb 52S1/2{5}^{2}{\mathrm{S}}_{1/2}52S1/2​ (F = 2) \ensuremath{\rightarrow} 52P3/2{5}^{2}{\mathrm{P}}_{3/2}52P3/2​ (F\ensuremath{'} = 3) using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides higher signal-to-noise ratio and sensitivity. After correcting for systematic perturbations, the absolute frequency was measured to be 384 228 115 200.7(2.7) kHz. A nearly 300-MHz microwave signal, whose phase exactly tracked that of the optical-frequency standard, was generated via the optical-frequency comb, yielding a frequency instability of 1.91 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}13}$ at 1 s and 5.29 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}14}$ at 1000 s in the electronic domain. The reproducibility was measured to be 3.66 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ by comparing results from four independent daily measurements, each conducted following a complete system shutdown and restart. This is among the most precise frequency stabilization results for the first-excited-state transition of alkali metal atoms to date, and represents an optical clock based on this transition. This work offers a promising approach for the development of portable optical clocks.
We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.