Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2501.01826 · Physical Review Applied

Compact 780-nm Rb optical clock

Zhendong Chen, Tianyu Liu, Ruoao Yang, Qiaohui Yang, Ya Wang, Jie Miao, Jingming Chen, Duo Pan, Shiying Cao, Zhigang Zhang, Jianjun Wu, Jingbiao Chen

Published Nov 24, 2025• 4 citations
arXivHTMLPDF

Abstract

We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.

DOI
10.1103/6pt5-zgmd

Related papers

A Compact Rubidium Optical Clock Based on Modulation Transfer Spectrum

Zhendong Chen, Ruoao Yang, Yang Qiaohui +7 more

A compact rubidium optical clock is presented, incorporating an optical frequency standard, a fiber frequency comb, and associated control electronics. Modulation transfer spectroscopy, devoid of Doppler background and characterized by a high signal-to-noise ratio and sensitivity, is employed to lock the laser frequency to the hyperfine transitions of rubidium atomic lines. The clock exhibits a short-term stability of 4.10 × 10-13at a 1-second gate time, and the stability remains below 7.27 × 10-13up to 1000 seconds. These results offer a promising alternative approach for the development of portable optical clocks.

IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS)•Sep 22, 2024•0 citations

Compact and frequency stabilized laser heads for Rubidium atomic clocks

Florian Gruet, Matthieu Pellaton, C. Affolderbach +3 more

We present the development and complete spectral characterization of our compact and frequency-stabilized laser heads, to be used for rubidium atomic clocks and basic spectroscopy. The light source is a Distributed Feed-Back (DFB) laser diode emitting at 780 nm or 795 nm. The laser frequency is stabilized on a sub-Doppler absorption peak of the 87Rb atom, obtained from an evacuated rubidium cell. These laser heads, including the electronics for the light signals detection, have an overall volume of 0.63 liters. We also present a variant of the laser head into which is integrated an Acousto-Optical Modulator (AOM) that precisely detunes the laser frequency in order to minimize the AC Stark shift in Rb atomic clocks.

International Conference on Space Optics (ICSO)•Nov 20, 2017•20 citations

Progress Towards the Development of a Portable All-optical Atomic Clock Based on a Two-photon Transition in Warm Atomic Vapor

S. Jana, B. K. Sahoo, Arijit Sharma

Optical clocks represent the hallmark of precise timekeeping. The most precise atomic clocks are laboratory-based ones that utilize transitions in the microwave/optical domain of neutral atoms or trapped ions. These clocks define an international time scales, confirm the consistency of physical constants and stimulate the search for new physics outside the Standard Model. The other area is the regime of portable atomic clocks based on warm atomic vapor, which is small, power-efficient and deployable in the field with a variety of civilian applications, including sensing, communication and navigation. Two-photon resonance and optical transition based field deployable clocks present a viable alternative that may outperform current commercial chip scale clocks by at least a factor of 10 in terms of both long-term and short-term stability. For portable clocks, two-photon transitions in alkaline earth metals are of special interest. One of the systematic inaccuracies in the optical reference is eliminated by using counter-propagating laser beams to create Doppler-free spectroscopy. At IIT Tirupati, we are engaged in developing the next generation of atomic vapor based portable frequency standard using two-photon transition in Rubidium (Rb) for atomic sensing and quantum positioning applications. This article discusses the physics behind the two-photon transition in Rubidium atoms suitable for a clock reference. Briefly, it discusses the experimental methodology for realizing an optical clock using warm rubidium vapor.

URSI Regional Conference on Radio Science (URSI-RCRS)•Dec 1, 2022•1 citation

Miniaturized optical frequency reference for next-generation portable optical clocks

Vincent N. Maurice, Zachary L. Newman, Susannah M. Dickerson +7 more

Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10−12/ τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

arXiv:2003.13172•Optics Express•Jul 15, 2020•71 citations

Compact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium

Kyle W. Martin, Gretchen R. Phelps, N. Lemke +7 more

Optical frequency standards surpass their microwave counterparts in both stability and accuracy, yet they are often bulky, power-hungry, and unable to operate outside of a well-controlled laboratory environment. Leveraging a two-photon transition in ${}^{87}$Rb vapor and recent advances in fiber frequency combs, the authors build an optical clock to beat the current portable standards, with an architecture that can be made compact and low-power. These results point the way to a real-world optical frequency standard of even higher stability, for applications such as satellite navigation.

arXiv:1903.11231•Physical Review Applied•Jan 18, 2018•171 citations

High-Stability Rb Optical Clock Based on Pulse-Modulated Broad-Spectrum Comb-Tooth Laser

Xiaolei Guan, Tiantian Shi, Jianxiang Miao +2 more

We have proposed a new scheme to realize the Rb optical clock using a pulse-modulated broad-spectrum multi-frequency laser. By applying a pulse-modulated signal to a 420 nm external cavity diode laser, a broad-spectrum comb-tooth laser with multiple frequency components is generated, which can interact with almost all the Rb atoms with different transverse velocities, so that more Rb atoms in the Rb cell can contribute to the frequency stabilization signal of the clock transition spectral line. The effective atomic number is expected to be improved by a factor of 102- 103, which will significantly improve the signal-to-noise ratio of spectrum, so as to optimize the frequency stability of Rb optical clock. The Rb optical frequency standard with high stability can be widely used in laser physics and precision measurement.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•0 citations
We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.
A compact rubidium optical clock is presented, incorporating an optical frequency standard, a fiber frequency comb, and associated control electronics. Modulation transfer spectroscopy, devoid of Doppler background and characterized by a high signal-to-noise ratio and sensitivity, is employed to lock the laser frequency to the hyperfine transitions of rubidium atomic lines. The clock exhibits a short-term stability of 4.10 × 10-13at a 1-second gate time, and the stability remains below 7.27 × 10-13up to 1000 seconds. These results offer a promising alternative approach for the development of portable optical clocks.
We present the development and complete spectral characterization of our compact and frequency-stabilized laser heads, to be used for rubidium atomic clocks and basic spectroscopy. The light source is a Distributed Feed-Back (DFB) laser diode emitting at 780 nm or 795 nm. The laser frequency is stabilized on a sub-Doppler absorption peak of the 87Rb atom, obtained from an evacuated rubidium cell. These laser heads, including the electronics for the light signals detection, have an overall volume of 0.63 liters. We also present a variant of the laser head into which is integrated an Acousto-Optical Modulator (AOM) that precisely detunes the laser frequency in order to minimize the AC Stark shift in Rb atomic clocks.
Optical clocks represent the hallmark of precise timekeeping. The most precise atomic clocks are laboratory-based ones that utilize transitions in the microwave/optical domain of neutral atoms or trapped ions. These clocks define an international time scales, confirm the consistency of physical constants and stimulate the search for new physics outside the Standard Model. The other area is the regime of portable atomic clocks based on warm atomic vapor, which is small, power-efficient and deployable in the field with a variety of civilian applications, including sensing, communication and navigation. Two-photon resonance and optical transition based field deployable clocks present a viable alternative that may outperform current commercial chip scale clocks by at least a factor of 10 in terms of both long-term and short-term stability. For portable clocks, two-photon transitions in alkaline earth metals are of special interest. One of the systematic inaccuracies in the optical reference is eliminated by using counter-propagating laser beams to create Doppler-free spectroscopy. At IIT Tirupati, we are engaged in developing the next generation of atomic vapor based portable frequency standard using two-photon transition in Rubidium (Rb) for atomic sensing and quantum positioning applications. This article discusses the physics behind the two-photon transition in Rubidium atoms suitable for a clock reference. Briefly, it discusses the experimental methodology for realizing an optical clock using warm rubidium vapor.
Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10−12/ τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.
Optical frequency standards surpass their microwave counterparts in both stability and accuracy, yet they are often bulky, power-hungry, and unable to operate outside of a well-controlled laboratory environment. Leveraging a two-photon transition in 87{}^{87}87Rb vapor and recent advances in fiber frequency combs, the authors build an optical clock to beat the current portable standards, with an architecture that can be made compact and low-power. These results point the way to a real-world optical frequency standard of even higher stability, for applications such as satellite navigation.
We have proposed a new scheme to realize the Rb optical clock using a pulse-modulated broad-spectrum multi-frequency laser. By applying a pulse-modulated signal to a 420 nm external cavity diode laser, a broad-spectrum comb-tooth laser with multiple frequency components is generated, which can interact with almost all the Rb atoms with different transverse velocities, so that more Rb atoms in the Rb cell can contribute to the frequency stabilization signal of the clock transition spectral line. The effective atomic number is expected to be improved by a factor of 102- 103, which will significantly improve the signal-to-noise ratio of spectrum, so as to optimize the frequency stability of Rb optical clock. The Rb optical frequency standard with high stability can be widely used in laser physics and precision measurement.