arXiv:2105.00610 · Optics Letters

High-performance, compact optical standard

Zachary L. Newman, Vincent N. Maurice, Connor D. Fredrick, Tara M. Fortier, Holly Leopardi, Leo W. Hollberg, Scott A. Diddams, John E. Kitching, Matthew T. Hummon

Published Aug 17, 2021• 77 citations
arXivHTMLPDF

Abstract

We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8 × 10 − 13 τ − 1 / 2 for times less than 100 s and a flicker noise floor of 1 × 10 − 14 out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the ac Stark shift. The retrace was measured to 5.7 × 10 − 13 after 30 h of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.

DOI
10.1364/ol.435603

Related papers

A Comprehensive Review of Rubidium Two-Photon Vapor Cell Optical Clock: Long-Term Performance Limitations and Potential Improvements

Asagwegbe C. Obaze-Adeleke, Bryan Semon, Thejesh Bandi

Two-photon vapor cell-based optical clocks are strong candidates for next-generation portable atomic standards, offering simplicity, compactness, and high performance. Their narrow clock transitions with counter-propagating beams enable first-order Doppler-free operation. However, systematic perturbations such as the AC Stark shift, temperature-induced shift, and drifts resulting from the laser system pose challenges cause instabilities to medium- to long-term performance. This paper provides a comprehensive overview of Rb two-photon vapor cell optical standards, focusing on the long-term performance-limiting effects and potential mitigation strategies, aiming for clock stabilities better than 1 × 10−15 over the averaging time of a day and beyond.

Photonics•May 20, 2025•10 citations

Atomic frequency standard based on direct frequency comb spectroscopy

Seth E. Erickson, Dylan P. Tooley, Kushan Weerasinghe +3 more

We have developed a high performance atomic frequency standard based on Doppler-free direct frequency comb excitation of a two-photon transition in 87 Rb. We demonstrate equivalent performance compared to an identical system based on cw laser excitation of the clock transition. This approach greatly simplifies optical clock architecture and eliminates the need for cw lasers in many two-photon frequency standards. The clock transition linewidth and ac-Stark shift measured directly with the frequency comb are shown to be nearly identical to those obtained using a cw laser of equal average power. We directly count this reference via the frequency comb repetition rate, achieving instabilities of 1.9 × 10 −13 at 1 s averaging down to 7.8(38) × 10 −15 at 2600 s, currently limited by temperature dependent shifts.

Optics Letters•Aug 8, 2024•4 citations

Short-term stability of a microcell optical reference based on the Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

Journal of the Optical Society of America B•Nov 22, 2024•14 citations

Compact 780-nm Rb optical clock

Zhendong Chen, Tianyu Liu, Ruoao Yang +9 more

We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.

arXiv:2501.01826•Physical Review Applied•Nov 24, 2025•4 citations

Short-term stability of a microcell optical reference based on Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5 $\times$ 10$^{-13}$ $τ^{-1/2}$ until 200~s, in good agreement with a phase noise level of $+$ 43 dBrad$^2$/Hz at 1~Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. With still a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

arXiv:2407.00841•Jun 30, 2024•0 citations

Characterization of Frequency-Doubled 1.5-$\mu$ m Lasers for High-Performance Rb Clocks

Nil Almat, William Moreno, Matthieu Pellaton +3 more

We report on the characterization of two fiber-coupled 1.5-μm diode lasers, frequency-doubled and stabilized to Rubidium (Rb) atomic resonances at 780 nm. Such laser systems are of interest in view of their implementation in Rb vapor-cell atomic clocks, as an alternative to lasers emitting directly at 780 nm. The spectral properties and the instabilities of the frequency-doubled lasers are evaluated against a state-of-the-art compact Rb-stabilized laser system based on a distributed-feedback laser diode emitting at 780 nm. All three lasers are frequency stabilized using essentially identical Doppler-free spectroscopy schemes. The long-term optical power fluctuations at 780 nm are measured, simultaneously with the frequency instability measurements done by three beat notes established between the three lasers. One of the frequency-doubled laser systems shows at 780 nm excellent spectral properties. Its relative intensity noise-12Hz-1is one order of magnitude lower than the reference 780-nm laser, and the frequency noise6Hz2/Hz is limited by the laser current source. Its optical frequency instability is-12at τ = 1 s, limited by the reference laser, and better than 1 × 10-11at all timescales up to one day. We also evaluate the impact of the laser spectral properties and instabilities on the Rb atomic clock performance, in particular taking into account the light-shift effect. Optical power instabilities on long-term timescales, largely originating from the frequency-doubling stage, are identified as a limitation in view of high-performance Rb atomic clocks.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jan 15, 2018•9 citations
We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8 × 10 − 13 τ − 1 / 2 for times less than 100 s and a flicker noise floor of 1 × 10 − 14 out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the ac Stark shift. The retrace was measured to 5.7 × 10 − 13 after 30 h of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.
Two-photon vapor cell-based optical clocks are strong candidates for next-generation portable atomic standards, offering simplicity, compactness, and high performance. Their narrow clock transitions with counter-propagating beams enable first-order Doppler-free operation. However, systematic perturbations such as the AC Stark shift, temperature-induced shift, and drifts resulting from the laser system pose challenges cause instabilities to medium- to long-term performance. This paper provides a comprehensive overview of Rb two-photon vapor cell optical standards, focusing on the long-term performance-limiting effects and potential mitigation strategies, aiming for clock stabilities better than 1 × 10−15 over the averaging time of a day and beyond.
We have developed a high performance atomic frequency standard based on Doppler-free direct frequency comb excitation of a two-photon transition in 87 Rb. We demonstrate equivalent performance compared to an identical system based on cw laser excitation of the clock transition. This approach greatly simplifies optical clock architecture and eliminates the need for cw lasers in many two-photon frequency standards. The clock transition linewidth and ac-Stark shift measured directly with the frequency comb are shown to be nearly identical to those obtained using a cw laser of equal average power. We directly count this reference via the frequency comb repetition rate, achieving instabilities of 1.9 × 10 −13 at 1 s averaging down to 7.8(38) × 10 −15 at 2600 s, currently limited by temperature dependent shifts.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5 ×\times× 10−13^{-13}−13 τ−1/2τ^{-1/2}τ−1/2 until 200~s, in good agreement with a phase noise level of +++ 43 dBrad2^22/Hz at 1~Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. With still a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
Characterization of Frequency-Doubled 1.5-μ\muμ m Lasers for High-Performance Rb Clocks
We report on the characterization of two fiber-coupled 1.5-μm diode lasers, frequency-doubled and stabilized to Rubidium (Rb) atomic resonances at 780 nm. Such laser systems are of interest in view of their implementation in Rb vapor-cell atomic clocks, as an alternative to lasers emitting directly at 780 nm. The spectral properties and the instabilities of the frequency-doubled lasers are evaluated against a state-of-the-art compact Rb-stabilized laser system based on a distributed-feedback laser diode emitting at 780 nm. All three lasers are frequency stabilized using essentially identical Doppler-free spectroscopy schemes. The long-term optical power fluctuations at 780 nm are measured, simultaneously with the frequency instability measurements done by three beat notes established between the three lasers. One of the frequency-doubled laser systems shows at 780 nm excellent spectral properties. Its relative intensity noise-12Hz-1is one order of magnitude lower than the reference 780-nm laser, and the frequency noise6Hz2/Hz is limited by the laser current source. Its optical frequency instability is-12at τ = 1 s, limited by the reference laser, and better than 1 × 10-11at all timescales up to one day. We also evaluate the impact of the laser spectral properties and instabilities on the Rb atomic clock performance, in particular taking into account the light-shift effect. Optical power instabilities on long-term timescales, largely originating from the frequency-doubling stage, are identified as a limitation in view of high-performance Rb atomic clocks.