Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Ramsey-CPT spectrum with the Faraday effect and its application to atomic clocks

Yuan Tian, Bo-Zhong Tan, Jing Yang, Yi Zhang, Sihong Gu

Published Jun 1, 2015• 10 citations
Publisher

Abstract

A method that obtains the Ramsey-coherent population trapping (CPT) spectrum with the Faraday effect is investigated. An experiment is implemented to detect the light polarization components generated from the Faraday effect. The experimental results agree with the theoretical calculations based on the Liouville equation. By comparing with the method without using the Faraday effect, the potential of this method for a CPT-based atomic clock is assessed. The results indicate that this method should improve the short-term frequency stability by several times.

DOI
10.1088/1674-1056/24/6/063302

Related papers

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•17 citations

Exploring Ramsey-coherent population trapping atomic clock realized with pulsed microwave modulated laser

Jing Yang, Yuan Tian, Bozhong Tan +2 more

A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.

Journal of Applied Physics•Mar 7, 2014•15 citations

Investigation of Ramsey spectroscopy in a lin-par-lin Ramsey coherent population trapping clock with dispersion detection

Xiaolin Sun, Jianwei Zhang, Pengfei Cheng +3 more

Rb clock using a dispersion detection technique has a promising performance. We theoretically and experimentally investigate the signal-to-noise ratio of the Ramsey spectrum signal by varying the relative angle of the polarizer and analyzer as well as the magnetic field. Based on the experimental results, the optimized relative angle and magnetic field are determined. This kind of atomic clock is attractive for the development of compact, high performance vapor clock based on CPT.

Optics Express•Feb 23, 2016•15 citations

Reduction of light shifts in Ramsey spectroscopy with a combined error signal

M. Shuker, J. W. Pollock, Rodolphe Boudot +4 more

Light-induced frequency shifts can be a key limiting contribution to the mid- and long-term frequency instabilities in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors, and instruments.

arXiv:1903.00566•Applied Physics Letters•Apr 8, 2019•27 citations

Frequency Stability of Atomic Clocks Based on Coherent Population Trapping Resonance in 85 Rb

Lu Liu, Guo Tao, Ke Deng +3 more

An atomic clock system based on coherent population trapping (CPT) resonance in 85 Rb is reported, while most past works about the CPT clock are in 87 Rb. A new modulation method (full-hyperfine-frequency-splitting modulation) is presented to reduce the effect of light shift to improve the frequency stability of the CPT clock in 85 Rb. The experimental results show that the short-term frequency stability of the CPT clock in 85 Rb is in the order of 10 −10 /s and the long-term frequency stability can achieve 1.5 × 10 −11 /80000 s, which performs as well as 87 Rb in CPT resonance. This very good frequency stability performance associated with the low-cost and low-power properties of 85 Rb indicates that an atomic clock based on CPT in 85 Rb should be a promising candidate for making the chip scale atomic clock.

Chinese Physics Letters•Jun 28, 2007•9 citations

Experimental study of the application feasibility of a novel chip-scale atomic clock scheme

Huifang Lin, Yuan Tian, Jie‐Hua Chen +1 more

Rb vapor cell with differential detection. Elliptically polarized light is used to interact with alkali atoms to generate coherent population trapping (CPT) resonance, and the CPT signal is obtained by detecting the Faraday rotation effect with differential detection technology. To move closer to an actual chip-scale atomic clock (CSAC), we reduce the volume of the experimental apparatus and use a divergent laser beam to interact with the atoms. We obtain the short-term frequency stability of the CSAC based on the differential detection scheme and compare it with that of a conventional CSAC. The results show that the frequency stability is more than two times better than that of current commercial CSAC devices with the same power consumption and volume.

Review of Scientific Instruments•May 1, 2019•6 citations
A method that obtains the Ramsey-coherent population trapping (CPT) spectrum with the Faraday effect is investigated. An experiment is implemented to detect the light polarization components generated from the Faraday effect. The experimental results agree with the theoretical calculations based on the Liouville equation. By comparing with the method without using the Faraday effect, the potential of this method for a CPT-based atomic clock is assessed. The results indicate that this method should improve the short-term frequency stability by several times.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.
A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.
Light-induced frequency shifts can be a key limiting contribution to the mid- and long-term frequency instabilities in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors, and instruments.
An atomic clock system based on coherent population trapping (CPT) resonance in 85 Rb is reported, while most past works about the CPT clock are in 87 Rb. A new modulation method (full-hyperfine-frequency-splitting modulation) is presented to reduce the effect of light shift to improve the frequency stability of the CPT clock in 85 Rb. The experimental results show that the short-term frequency stability of the CPT clock in 85 Rb is in the order of 10 −10 /s and the long-term frequency stability can achieve 1.5 × 10 −11 /80000 s, which performs as well as 87 Rb in CPT resonance. This very good frequency stability performance associated with the low-cost and low-power properties of 85 Rb indicates that an atomic clock based on CPT in 85 Rb should be a promising candidate for making the chip scale atomic clock.
Rb vapor cell with differential detection. Elliptically polarized light is used to interact with alkali atoms to generate coherent population trapping (CPT) resonance, and the CPT signal is obtained by detecting the Faraday rotation effect with differential detection technology. To move closer to an actual chip-scale atomic clock (CSAC), we reduce the volume of the experimental apparatus and use a divergent laser beam to interact with the atoms. We obtain the short-term frequency stability of the CSAC based on the differential detection scheme and compare it with that of a conventional CSAC. The results show that the frequency stability is more than two times better than that of current commercial CSAC devices with the same power consumption and volume.