Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Developmental study on an NbTiN HEB mixer for astronomical applications

謙 新保

Published Jan 1, 2008• 1 citation
OpenAlex

Related papers

Gain Bandwidth and Noise Temperature of NbTiN HEB Mixer

Gregory N Gol'tsman, Matvey I. Finkel, Yu. B. Vachtomin +4 more

•Apr 1, 2003•4 citations

Novel waveguide heterodyne mixers with superconducting tunnel junctions at millimeter wavelengths for astronomical and atmospheric applications

浅山信一郎

•Jan 1, 2004•0 citations

Stability of a Quasi-Optical Superconducting NbTiN Hot-Electron Bolometer Mixer at 1.5 THz Frequency Band

Hiroyuki Maezawa, T. Yamakura, T. Shiino +10 more

We are developing quasi-optical superconducting hot-electron bolometer (HEB) mixer receivers for astronomical and atmospheric remote sensing applications. The microbridge of the HEB mixer was fabricated at room temperature from a 6.8-nm-thick niobium titanium nitride (NbTiN) film deposited on a 20-nm-thick aluminum nitride (AlN) buffer layer, using a helicon sputtering technique at a slow deposition rate. The mixer was cooled to 4.2 K using a closed-cycled mechanical 4 K pulse-tube cryocooler with a temperature fluctuation of$\pm$1.6 mK. The stability of a large-volume NbTiN HEB mixer was studied at 1.47 THz by changing local oscillator (LO) power with the mixer bias voltage fixed. The intermediate frequency (IF) signal measured at 1.5 GHz had a maximum peak at a certain mixer bias current. The receiver noise temperature was lowest at around the IF maximum peak. It was also found that the IF signal was most stable at around the IF maximum peak under conditions in which the instability of LO pumping level, induced by small mechanical vibrations of the cryostat, remained in the optical system.

IEEE Transactions on Applied Superconductivity•Jan 24, 2011•6 citations

Design and fabrication of superconducting HEB mixer

Jinping Wang, YangBin Li, Lin Kang +7 more

中国科学通报:英文版•Jun 1, 2009•7 citations

Integration and Characterisation of Superconducting HEB Mixers for the Herschel Space Observatory

Therese Berg

•Jan 1, 2005•0 citations

Low-noise 1.5 THz waveguide-type hot-electron bolometer mixers using relatively thick NbTiN superconducting film

Tatsuya Shiino, Ryuta Furuya, Tatsuya Soma +7 more

Abstract We have developed waveguide-type low-noise superconducting hot-electron bolometer (HEB) mixers for astronomical observations in the 1.3–1.5 THz region by using a relatively thick NbTiN superconducting film (10.8 nm). We have achieved a receiver noise temperature of 490 K (DSB: double side band) at 1.475 THz. This noise temperature corresponds to seven times the quantum noise. According to gain bandwidth measurements, the contribution of diffusion cooling is found to be responsible for such a good noise performance.

Japanese Journal of Applied Physics•Feb 20, 2015•1 citation
We are developing quasi-optical superconducting hot-electron bolometer (HEB) mixer receivers for astronomical and atmospheric remote sensing applications. The microbridge of the HEB mixer was fabricated at room temperature from a 6.8-nm-thick niobium titanium nitride (NbTiN) film deposited on a 20-nm-thick aluminum nitride (AlN) buffer layer, using a helicon sputtering technique at a slow deposition rate. The mixer was cooled to 4.2 K using a closed-cycled mechanical 4 K pulse-tube cryocooler with a temperature fluctuation of$\pm$1.6 mK. The stability of a large-volume NbTiN HEB mixer was studied at 1.47 THz by changing local oscillator (LO) power with the mixer bias voltage fixed. The intermediate frequency (IF) signal measured at 1.5 GHz had a maximum peak at a certain mixer bias current. The receiver noise temperature was lowest at around the IF maximum peak. It was also found that the IF signal was most stable at around the IF maximum peak under conditions in which the instability of LO pumping level, induced by small mechanical vibrations of the cryostat, remained in the optical system.
Abstract We have developed waveguide-type low-noise superconducting hot-electron bolometer (HEB) mixers for astronomical observations in the 1.3–1.5 THz region by using a relatively thick NbTiN superconducting film (10.8 nm). We have achieved a receiver noise temperature of 490 K (DSB: double side band) at 1.475 THz. This noise temperature corresponds to seven times the quantum noise. According to gain bandwidth measurements, the contribution of diffusion cooling is found to be responsible for such a good noise performance.