Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Preliminary Frequency Comparison of Two 40 Ca + Optical Frequency Standards

Peiliang Liu, Yao Huang, Bian Wu, Hongyong Shao, Yuan Qian, Hua Guan, Kelin Gao

Published Nov 1, 2014• 6 citations
Publisher

Abstract

Frequency comparison is one of the most efficient ways to evaluate the performance of a frequency standard. Based on the pre-existing 40Ca+ optical frequency standard, we set up the second 40Ca+ optical frequency standard, which has been improved in the materials and structure of ion traps for better control of the magnetic field. After the compensation, the residual magnetic field at the position of the ion is adjusted to be ∼500 nT with a long time jitter of ∼10nT, which is better than the pre-existing 40Ca+ optical frequency standard. We realize the '4-point-closed-loop locking' on the second 40Ca+ optical frequency standard after a series of preparatory works. Through half an hour of measurement time, the two frequency standards exhibited a stability of 2.1 × 10−13 τ −1/2 and a relative frequency difference of 1.5 (2.9) Hz.

DOI
10.1088/0256-307x/31/11/113702

Related papers

Optical frequency standard based on a single 40Ca+

Kelin Gao

Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.

Chinese Science Bulletin•Mar 1, 2013•14 citations

40Ca+ optical frequency standards with high accuracy

Guan Hua, Yao Huang, Chengbin Li +1 more

With the development of the technologies in the lasers and the manipulation of cold atoms, the high precision optical frequency standards have been extensively studied and built in recent years. These high precision frequency standards may play an important role in establishing the new time reference, promoting the researches in the fundamental fields, fulfilling the national strategic needs, etc. In this paper, the research progress of high accuracy 40Ca+ optical frequency standard in Wuhan Institute of Physics and Mathematics (WIPM) of Chinese Academy of Sciences is presented. A new ULE super cavity is adopted for stabilizing the frequency of 729 nm clock laser, and the stability of the laser is improved now to 2×10-15 in a duration of 1-100 s. By controlling the external fields and other environmental influences, especially suppressing the micromotion effects of the trapped ion, the uncertainty of the optical frequency standard based on a single 40Ca+ is reduced to 5.5×10-17. The stability of 5×10-17 in a duration of 20000 s is achieved via the comparison between two 40Ca+ optical frequency standards. Several precision measurement experiments are performed, based on the high precision 40Ca+ optical frequency standard. The absolute value of the clock transition frequency of the 40Ca+ optical frequency standard is measured second time, using an optical comb referenced to a hydrogen maser which is calibrated via GPS referenced to UTC (NIM)) using the precise point positioning data-processing technique. The frequency offset of UTC (NIM) relative to the SI second can be evaluated through BIPM circular-T reports, and the newly measured value of m 4s 2S1/2-3m d 2D5/2 transition is adopted by CCTF-20, thus updating the recommended value of 40Ca+ optical clock transition. Besides the absolute frequency measurement, the magic wavelengths of 40Ca+ optical clock transition are measured precisely, and this work is a milestone for establishing all-optical trapped-ion clocks. The lifetime of the m 3 d 2D3/2 and m 3 d 2D5/2 state in 40Ca+ are precisely measured, too. The work mentioned above contributes to the researches of the precision measurements based on cold atomic systems.

Acta Physica Sinica•Jan 1, 2018•4 citations

40Ca+ optical clocks in China

Hua Guan, Baolin Zhang, Huaqing Zhang +4 more

In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.

AVS Quantum Science•Oct 11, 2021•4 citations

Direct comparison of multi-ion optical clocks based on 40 Ca + and 88 Sr +

Yosef Sokolik, Roee Ozeri, Nitzan Akerman

We report the first direct frequency comparison between two multi-ion optical clocks based on the S$_{1/2}$ to D$_{5/2}$ transition in \Ca and \Sr ions. Using linear chains of up to nine \Ca ions and six \Sr ions, we demonstrate improved stability as a function of the number of ions that are contributing to the laser frequency stabilization servo. The measured joint fractional frequency stability of the two clocks reaches $1.37(12)\times 10^{-15}$ at one second, placing an upper bound on the same stability of one of the clocks at $9.6(8)\times 10^{-16}$ in one second. We measured the frequency ratio of the two clocks to be $R_{\text{Sr/Ca}}=1.082076536381896986(18)$, where the systematic uncertainty is primarily limited by the room temperature blackbody radiation. Our direct measurement represents an order of magnitude improvement compared to existing indirect frequency ratio measurements. Furthermore, by combining our results with recent absolute frequency measurements of the \Sr transition, referenced to a primary frequency standard, we refined the absolute frequency of the \Ca transition to $ν_{\text{Ca}^+}=411042129776400.21(4)$ Hz, reducing its uncertainty by a factor of three. This study presents the first direct comparison between two multi-ion optical clocks, highlighting their significant potential for future applications in fundamental physics tests, geodesy, and precision metrology.

arXiv:2602.05626•Physical Review Letters•Nov 9, 2026•4 citations

The progress of the precision spectroscopy with single trapped and laser cooled 40Ca+ ion

Hua Guan, 高克林, Yao HUANG

The experimental study at Wuhan Institute of Physics and Mathematics (WIPM), Chinese Academy of Scienses (CAS) on the precision spetroscopy based on single trapped Ca+ ion is described in this paper. A single Ca+ ion is trapped in a miniature Paul trap and laser cooled to Lamb-Dicke regime, and the ion can be trapped more than 2 months. The linewidth of the 729 nm laser for probing the Ca+ 4s2S1/2-3d2D5/2 clock transition is reduced to lessthan 1 Hz by locked to a super cavity, and the 729 nm laser can be locked more than 1 month continuously. Two similar Ca + ion optical frequency standards are set up for frequency comparison. The systematic uncertainty is evaluated to be <6 ´ 10−17 for both ftrquency standards. The frequency difference of two frequency standards is measured to be 3.0 (5.5) ´ 10−17 within 42 d. The Allan deviation for a single clock is measured to be 1×10−14τ−1/2 with a 3-d-continuous comparison, the stability for a reaches 7 ´ 10−17 at an averaging time of 20000 s. Meanwhile, the absolute frequency of the Ca+ 4s2S1/2-3d2D5/2 clock transition is measured to be 411042129776401.7(1.1) Hz with respect to the SI second through the Global Positioning System (GPSx). The precision spectroscopy experiments are carried out based on the single Ca+ ion system. The magic wavelengths for the Ca+ optical frequency standardare measured to be λ|mj|=1/2=395.7992(7) nm and λ|mj|=3/2=395.7990(7) nm, which agrees with theoretical calculation made by Tang et al. The lifetime of the 3d2D5/2 is measured to be 1174(10) ms, which is agree with the experimental measurement made by University of Oxford and University of Innsbruck and the recent theoretical calculation made by Sahoo.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Jun 17, 2016•0 citations

Frequency measurement of the40Ca+clock transition using a LD-based clock laser and UTC(NICT)

K. Matsubara, Y. Li, Shigeo Nagano +6 more

We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 20, 2009•1 citation
Frequency comparison is one of the most efficient ways to evaluate the performance of a frequency standard. Based on the pre-existing 40Ca+ optical frequency standard, we set up the second 40Ca+ optical frequency standard, which has been improved in the materials and structure of ion traps for better control of the magnetic field. After the compensation, the residual magnetic field at the position of the ion is adjusted to be ∼500 nT with a long time jitter of ∼10nT, which is better than the pre-existing 40Ca+ optical frequency standard. We realize the '4-point-closed-loop locking' on the second 40Ca+ optical frequency standard after a series of preparatory works. Through half an hour of measurement time, the two frequency standards exhibited a stability of 2.1 × 10−13 τ −1/2 and a relative frequency difference of 1.5 (2.9) Hz.
Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.
With the development of the technologies in the lasers and the manipulation of cold atoms, the high precision optical frequency standards have been extensively studied and built in recent years. These high precision frequency standards may play an important role in establishing the new time reference, promoting the researches in the fundamental fields, fulfilling the national strategic needs, etc. In this paper, the research progress of high accuracy 40Ca+ optical frequency standard in Wuhan Institute of Physics and Mathematics (WIPM) of Chinese Academy of Sciences is presented. A new ULE super cavity is adopted for stabilizing the frequency of 729 nm clock laser, and the stability of the laser is improved now to 2×10-15 in a duration of 1-100 s. By controlling the external fields and other environmental influences, especially suppressing the micromotion effects of the trapped ion, the uncertainty of the optical frequency standard based on a single 40Ca+ is reduced to 5.5×10-17. The stability of 5×10-17 in a duration of 20000 s is achieved via the comparison between two 40Ca+ optical frequency standards. Several precision measurement experiments are performed, based on the high precision 40Ca+ optical frequency standard. The absolute value of the clock transition frequency of the 40Ca+ optical frequency standard is measured second time, using an optical comb referenced to a hydrogen maser which is calibrated via GPS referenced to UTC (NIM)) using the precise point positioning data-processing technique. The frequency offset of UTC (NIM) relative to the SI second can be evaluated through BIPM circular-T reports, and the newly measured value of m 4s 2S1/2-3m d 2D5/2 transition is adopted by CCTF-20, thus updating the recommended value of 40Ca+ optical clock transition. Besides the absolute frequency measurement, the magic wavelengths of 40Ca+ optical clock transition are measured precisely, and this work is a milestone for establishing all-optical trapped-ion clocks. The lifetime of the m 3 d 2D3/2 and m 3 d 2D5/2 state in 40Ca+ are precisely measured, too. The work mentioned above contributes to the researches of the precision measurements based on cold atomic systems.
In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.
We report the first direct frequency comparison between two multi-ion optical clocks based on the S1/2_{1/2}1/2​ to D5/2_{5/2}5/2​ transition in \Ca and \Sr ions. Using linear chains of up to nine \Ca ions and six \Sr ions, we demonstrate improved stability as a function of the number of ions that are contributing to the laser frequency stabilization servo. The measured joint fractional frequency stability of the two clocks reaches 1.37(12)×10−151.37(12)\times 10^{-15}1.37(12)×10−15 at one second, placing an upper bound on the same stability of one of the clocks at 9.6(8)×10−169.6(8)\times 10^{-16}9.6(8)×10−16 in one second. We measured the frequency ratio of the two clocks to be RSr/Ca=1.082076536381896986(18)R_{\text{Sr/Ca}}=1.082076536381896986(18)RSr/Ca​=1.082076536381896986(18), where the systematic uncertainty is primarily limited by the room temperature blackbody radiation. Our direct measurement represents an order of magnitude improvement compared to existing indirect frequency ratio measurements. Furthermore, by combining our results with recent absolute frequency measurements of the \Sr transition, referenced to a primary frequency standard, we refined the absolute frequency of the \Ca transition to νCa+=411042129776400.21(4)ν_{\text{Ca}^+}=411042129776400.21(4)νCa+​=411042129776400.21(4) Hz, reducing its uncertainty by a factor of three. This study presents the first direct comparison between two multi-ion optical clocks, highlighting their significant potential for future applications in fundamental physics tests, geodesy, and precision metrology.
The experimental study at Wuhan Institute of Physics and Mathematics (WIPM), Chinese Academy of Scienses (CAS) on the precision spetroscopy based on single trapped Ca+ ion is described in this paper. A single Ca+ ion is trapped in a miniature Paul trap and laser cooled to Lamb-Dicke regime, and the ion can be trapped more than 2 months. The linewidth of the 729 nm laser for probing the Ca+ 4s2S1/2-3d2D5/2 clock transition is reduced to lessthan 1 Hz by locked to a super cavity, and the 729 nm laser can be locked more than 1 month continuously. Two similar Ca + ion optical frequency standards are set up for frequency comparison. The systematic uncertainty is evaluated to be <6 ´ 10−17 for both ftrquency standards. The frequency difference of two frequency standards is measured to be 3.0 (5.5) ´ 10−17 within 42 d. The Allan deviation for a single clock is measured to be 1×10−14τ−1/2 with a 3-d-continuous comparison, the stability for a reaches 7 ´ 10−17 at an averaging time of 20000 s. Meanwhile, the absolute frequency of the Ca+ 4s2S1/2-3d2D5/2 clock transition is measured to be 411042129776401.7(1.1) Hz with respect to the SI second through the Global Positioning System (GPSx). The precision spectroscopy experiments are carried out based on the single Ca+ ion system. The magic wavelengths for the Ca+ optical frequency standardare measured to be λ|mj|=1/2=395.7992(7) nm and λ|mj|=3/2=395.7990(7) nm, which agrees with theoretical calculation made by Tang et al. The lifetime of the 3d2D5/2 is measured to be 1174(10) ms, which is agree with the experimental measurement made by University of Oxford and University of Innsbruck and the recent theoretical calculation made by Sahoo.
We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.