Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
Frequency measurement of the40Ca+clock transition using a LD-based clock laser and UTC(NICT)
K. Matsubara, Y. Li, Shigeo Nagano, Hiroyuki Ito, Masatoshi Kajita, Reiko Kojima, K. Hayasaka, Mizuhiko Hosokawa, Yuko Hanado
Abstract
We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.