Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

INFLUENCE OF CAVITY LOSS ON GENERATION OF STEADY STATE FOURTH-ORDER AND SQUARED AMPLITUDE SQUEEZING IN MICROMASER

Li Fu-Li, 西安交通大学应用物理系,西安710049

Published Jan 1, 1996• 0 citations
Publisher

Abstract

The generation of the steady state fourth-order squeezing and squared amplitude squeezing in a micromaser by the coherent trapping approach is investigated. The results show that if two-level atoms injected into the cavity are initially in coherent state and the flight time of the atoms inside the cavity satisfies the trapping condition, the field can evolve into a coherent trapping state which exhibits steady state fourth-order squeezing and squared amplitude squeezing in the cavity as long as the flux of the atoms is moderately large.

DOI
10.7498/aps.45.563

Related papers

Generation of higher-order squeezing in a micromaser

Fuli Li, D. L. Lin

The fourth-order squeezing and amplitude-squared squeezing of cotangent states produced in one-atom micromasers are investigated. It is found that optimal squeezing in the cotangent state can be achieved by properly choosing the relative amplitudes of the atomic coherent state. From our study of the dynamic process of the generation of steady-state fourth-order squeezing and amplitude-squared squeezing in one-atom micromasers, it is also shown that for sufficiently large atomic flux, the cavity loss, and finite temperature in the cavity have very little influence on the generation of these higher-order squeezings in practice.

Journal of Physics B Atomic Molecular and Optical Physics•Aug 28, 1997•13 citations

Generation of High-Order Squeezing in Multiphoton Micromaser

Fuli Li, Qing Huang

The generation of steady state higher-order squeezing in the sense of Hong and Mandel and also of Hillery in a multiphoton micromaser is studied. The results show that the cotangent state which is generated by the coherent trapping scheme in a multiphoton micromaser can exhibit not only second-order squeezing but also fourth-order and squared field amplitude squeezings. The influence of the cavity loss on the squeezings is investigated.

•Jan 1, 1996•0 citations

SQUEEZING AND AMPLITUDE-SQUARED SQUEEZING IN THE MODEL OF TWO NONIDENTICAL TWO-LEVEL ATOMS

Eugene K. Bashkirov

Squeezing and amplitude-squared squeezing for two two-level nonidentical atoms in lossless cavity has been investigated assuming the field to be initially in the coherent state. The time-dependent squeezing parameters have been calculated. The influence of the relative difference of two coupling constants on the squeezing parameters has been analyzed.

International Journal of Modern Physics B•Jan 20, 2007•6 citations

Phase squeezing in a three-level atom micromaser

Luis Roa

I consider a lossless micromaser with cascade three-level atoms in a coherent superposition of its three levels. I find that for some values of the atomic flight time and some probability amplitudes for the intermediate atomic level, the field evolves to a pure state which is the well-known general squeezed state, and the squeeze and displacement parameters are functions of the atomic input parameters. Therefore it is possible to choose atomic parameters which produce squeezing in the phase or in the amplitude of the field inside the cavity.

Physical Review A•Sep 1, 1994•10 citations

QUANTUM STATISTICAL PROPERTIES OF RADIATION

Shahid Qamar

We present a study on the quantum statistical properties of radiation in a one-photon micromaser. In particular, the possibility of generating steady-state squeezing is investigated. The spectral properties of the radiation field in a micromaser are also studied. \n \nWe show that the steady-state squeezing can be generated in a lossless micromaser by injecting the atoms in a coherent superposition of upper and lower states. It is shown by considering initial vacuum number and thermal state of the cavity field, that for a particular choice of the interaction time field evolves to a squeezed state. Steady- state squeezing is found to be independent of the initial state of the cavity field. However, the temporal evolution of the squeezing depends on the initial state of the field. Effects of cavity losses and pump fluctuations on steady-state squeezing are also investigated. \n \nFinally, an exact analytic expression for the linewidth of a micromaser in the absence of cavity losses is obtained by evaluating the two-time correlation function. A comparison with the natural linewidth of laser shows that under certain conditions gain contribution to the linewidth is same in both the cases. We also, derive an exact expression for the phoston distribution function and show that for a particular choice of the interaction time, the number state of the field can be generated.

•Jan 1, 1993•0 citations

A THEORETICAL STUDY OF GENERATION OF A STRONG SQUEEZED CAVITY FIELD BY USE OF ONE PHOTON MICROMASER

LI Fu-li, 兰州大学现代物理系,兰州,730001,西安交通大学物理系,西安,710049

In this paper interaction of two-level atoms initially occupied the upper most level with a single mode of cavity field initially in a coherent state is investigated. Let the atoms interact in sequence with the field in equal time intervals and we find that the field can be kept in squeezed states and squeezed continuously in this process if initial intensity of the field is strong. The atoms interacting with the squeezed light are also discussed.

Acta Physica Sinica•Jan 1, 1990•0 citations
The generation of the steady state fourth-order squeezing and squared amplitude squeezing in a micromaser by the coherent trapping approach is investigated. The results show that if two-level atoms injected into the cavity are initially in coherent state and the flight time of the atoms inside the cavity satisfies the trapping condition, the field can evolve into a coherent trapping state which exhibits steady state fourth-order squeezing and squared amplitude squeezing in the cavity as long as the flux of the atoms is moderately large.
The fourth-order squeezing and amplitude-squared squeezing of cotangent states produced in one-atom micromasers are investigated. It is found that optimal squeezing in the cotangent state can be achieved by properly choosing the relative amplitudes of the atomic coherent state. From our study of the dynamic process of the generation of steady-state fourth-order squeezing and amplitude-squared squeezing in one-atom micromasers, it is also shown that for sufficiently large atomic flux, the cavity loss, and finite temperature in the cavity have very little influence on the generation of these higher-order squeezings in practice.
I consider a lossless micromaser with cascade three-level atoms in a coherent superposition of its three levels. I find that for some values of the atomic flight time and some probability amplitudes for the intermediate atomic level, the field evolves to a pure state which is the well-known general squeezed state, and the squeeze and displacement parameters are functions of the atomic input parameters. Therefore it is possible to choose atomic parameters which produce squeezing in the phase or in the amplitude of the field inside the cavity.
We present a study on the quantum statistical properties of radiation in a one-photon micromaser. In particular, the possibility of generating steady-state squeezing is investigated. The spectral properties of the radiation field in a micromaser are also studied. \n \nWe show that the steady-state squeezing can be generated in a lossless micromaser by injecting the atoms in a coherent superposition of upper and lower states. It is shown by considering initial vacuum number and thermal state of the cavity field, that for a particular choice of the interaction time field evolves to a squeezed state. Steady- state squeezing is found to be independent of the initial state of the cavity field. However, the temporal evolution of the squeezing depends on the initial state of the field. Effects of cavity losses and pump fluctuations on steady-state squeezing are also investigated. \n \nFinally, an exact analytic expression for the linewidth of a micromaser in the absence of cavity losses is obtained by evaluating the two-time correlation function. A comparison with the natural linewidth of laser shows that under certain conditions gain contribution to the linewidth is same in both the cases. We also, derive an exact expression for the phoston distribution function and show that for a particular choice of the interaction time, the number state of the field can be generated.