Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

In-situ measurement of magnetic field gradient in a magnetic shield by a spin-exchange relaxation-free magnetometer

Jiancheng Fang, Tao Wang, Hong Zhang, Yang Li, Hongwei Cai

Published Jun 1, 2015• 13 citations
Publisher

Abstract

A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam’s direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell’s transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium’s D1 line. Furthermore, the residual magnetic fields are measured with σ + - and σ – -polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm.

DOI
10.1088/1674-1056/24/6/060702

Related papers

Measurement of Equilibrium Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometers via the Steady-State Response to the Triaxial Magnetic Field

Faming Wang, Xiujie Fang, Bozheng Xing +5 more

This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•7 citations

In situ measurement of residual magnetic field in SERF atomic magnetometer based on transient response

Di Zhan, Yaoguo Wang, Jixi Lu

Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.

Advanced Sensor Systems and Applications•Nov 20, 2024•0 citations

Precise Determination of Magnetic Gradient Relaxation of Coupled Atomic Spin Ensemble in Spin-Exchange Relaxation-Free Co-Magnetometer

Xiujie Fang, Kai Wei, Wenfeng Fan +5 more

Inside a spin-exchange relaxation-free (SERF) co-magnetometer with a high-pressure buffer gas atomic cell, the magnetic field gradient causes the decoherence of atomic spins to produce magnetic-field gradient relaxation. This paper presents a new method for the accurate measurement of magnetic field gradient relaxation of alkali metal atoms and inert atoms of strongly coupled spin systems under triaxial magnetic field gradients in the K-Rb-21Ne co-magnetometer. The magnetic field gradient relaxation of alkali metal atoms is measured using a step magnetic field modulation method, and the magnetic field gradient relaxation of inert atoms is measured using a combined free induction decay and spin growth method. The method does not require the use of large background magnetic fields and RF fields to maintain the atoms in the SERF state, does not require additional optics, and is not affected by the pumping or detecting of optical power. A kinetic model that considers a large electron-equivalent magnetic field was designed and a gradient relaxation model was developed. The quadratic coefficients of the experimentally measured gradient relaxation curves fit the theoretical model well over the range of the applied magnetic field gradients, confirming the validity of the proposed method.

Photonics•Apr 3, 2023•3 citations

In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect

Jiancheng Fang, Tao Wang, Wei Quan +4 more

A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz(1/2), which was mainly dominated by the noise of the magnetic shield.

Review of Scientific Instruments•Jun 1, 2014•69 citations

Precise Measurement of Magnetic Shielding Residual Field and Light Shift Based on 87Rb Atomic Magnetometer

Binbin Zhao, Junjian Tang, Lin Li +2 more

Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•4 citations

Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

Jiajie Li, Ying Liu, Renjie Li +3 more

Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.

Results in Physics•Nov 30, 2023•11 citations
A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam’s direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell’s transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium’s D1 line. Furthermore, the residual magnetic fields are measured with σ + - and σ – -polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm.
This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.
Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.
Inside a spin-exchange relaxation-free (SERF) co-magnetometer with a high-pressure buffer gas atomic cell, the magnetic field gradient causes the decoherence of atomic spins to produce magnetic-field gradient relaxation. This paper presents a new method for the accurate measurement of magnetic field gradient relaxation of alkali metal atoms and inert atoms of strongly coupled spin systems under triaxial magnetic field gradients in the K-Rb-21Ne co-magnetometer. The magnetic field gradient relaxation of alkali metal atoms is measured using a step magnetic field modulation method, and the magnetic field gradient relaxation of inert atoms is measured using a combined free induction decay and spin growth method. The method does not require the use of large background magnetic fields and RF fields to maintain the atoms in the SERF state, does not require additional optics, and is not affected by the pumping or detecting of optical power. A kinetic model that considers a large electron-equivalent magnetic field was designed and a gradient relaxation model was developed. The quadratic coefficients of the experimentally measured gradient relaxation curves fit the theoretical model well over the range of the applied magnetic field gradients, confirming the validity of the proposed method.
A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz(1/2), which was mainly dominated by the noise of the magnetic shield.
Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.