Results in Physics

Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

Jiajie Li, Ying Liu, Renjie Li, Qian Cao, Tianwei Zhou, Yueyang Zhai

Published Nov 30, 2023• 11 citations
Publisher

Abstract

Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.

DOI
10.1016/j.rinp.2023.107231

Related papers

Analysis of effects of magnetic field gradient on atomic spin polarization and relaxation in optically pumped atomic magnetometers

Xiujie Fang, Kai Wei, Yueyang Zhai +6 more

The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

Optics Express•Jan 14, 2022•61 citations

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 10, 2025•4 citations

Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer

Fei Lu, Shuying Wang, Nuozhou Xu +3 more

Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.

Photonics•Oct 25, 2022•7 citations

Effects of Stochastic Magnetic Noise on the SERF Co‐Magnetometer

Feng Li, Zhuo Wang, Wenfeng Fan +4 more

Abstract Stochastic magnetic field noise has a non‐negligible negative impact on the performance of quantum precision measurement instruments such as spin‐exchange relaxation‐free (SERF) co‐magnetometer in terms of sensitivity and stability. Conventional magnetic field error analysis and suppression methods are not applicable to stochastic magnetic field noise. In this paper, a stochastic model of the SERF co‐magnetometer is proposed to analyze the mechanism of stochastic magnetic field noise. The mean and covariance propagation model of the SERF co‐magnetometer is given based on the stochasticity model and statistical principles. The analysis of simulation experiments reveals that reducing the longitudinal electron spin polarization can somewhat reduce the standard deviation of the system output caused by stochastic magnetic field noise. And the atomic ensembles are most resistant to stochastic magnetic field noise when the electron spin polarization strongly couples with the nuclear spin polarization. Finally, the experiments verified the above conclusions. In conclusion, this paper provides theoretical and experimental support for analyzing and suppressing the effect of stochastic magnetic field noise on the SERF co‐magnetometer, which is of great significance for improving the sensitivity and stability of the measurement.

Advanced Quantum Technologies•Apr 19, 2024•6 citations

The influence of modulated magnetic field on light absorption in SERF atomic magnetometer

Yan Yin, Binquan Zhou, Yaxiang Wang +4 more

A single-beam spin-exchange relaxation-free atomic magnetometer is ultra-sensitive in the zero field, which has great potential for the detection of a magnetoencephalogram. The addition of a modulated magnetic field is an important approach to achieve high sensitivity for devices of this kind. In this study, we discovered that the amplitude and frequency of the modulated magnetic field (modulation index 0–3) both influence the light absorption. We defined this effect into a function by combining theoretical analysis and the results of experiments. It is discovered that the transmission intensity decreases with an increase in the modulation index. This effect is weakened under the application of a high modulation index. In addition, the transmission intensity and bias magnetic field no longer follow a strict Lorentz curve, while a high degree of fit can be achieved by applying the numerical solution of the Bloch function. A compact magnetometer with a volume of 10 cm3 and a sensitivity of 20 fT/Hz is developed based on the single beam scheme for the proof of concept. Our study is crucial in two aspects: (1) Obtaining high sensitivity through a short measurement period and (2) alignment of the scale factor of the individual magnetometer in a detection array, which further pave the way for improvement in a magnetometer’s performance under a variety of optics platforms.

Review of Scientific Instruments•Jan 1, 2022•5 citations

In Situ Compensation of Triaxial Magnetic Field Gradient for Atomic Magnetometers

Ke Yang, Jixi Lu, Yanning Ma +4 more

Magnetic field gradients affect numerous modern sensitive measurements and physics studies using atomic ensemble, resulting in the loss of coherence. In some cases, the presence of small gradients can reduce the performance significantly. In this study, we propose an effectivein situmethod to compensate the triaxial magnetic field gradient for atomic magnetometers, based on multichannel atomic signals in one vapor cell. We design two novel gradient coils by solving closed-form equations to improve the accuracy and efficiency of compensation. We demonstrate the performance of the compensation method in a spin-exchange relaxation-free atomic magnetometer, which reduces the magnetic linewidth by 4.2%–7.6% under the same conditions at a compensation resolution of 50 pT/cm. The proposed coils generate gradients only along two axes and achieve triaxial decoupling, which compensates for the gradient completely without iteration. Our results may aid in suppressing atomic spin relaxations due to magnetic field gradients in several modern measurements and improve their performance, such as the detection of electric dipole moments, ultralow-field nuclear magnetic resonance, and biomagnetism.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•18 citations
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.
Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.
Abstract Stochastic magnetic field noise has a non‐negligible negative impact on the performance of quantum precision measurement instruments such as spin‐exchange relaxation‐free (SERF) co‐magnetometer in terms of sensitivity and stability. Conventional magnetic field error analysis and suppression methods are not applicable to stochastic magnetic field noise. In this paper, a stochastic model of the SERF co‐magnetometer is proposed to analyze the mechanism of stochastic magnetic field noise. The mean and covariance propagation model of the SERF co‐magnetometer is given based on the stochasticity model and statistical principles. The analysis of simulation experiments reveals that reducing the longitudinal electron spin polarization can somewhat reduce the standard deviation of the system output caused by stochastic magnetic field noise. And the atomic ensembles are most resistant to stochastic magnetic field noise when the electron spin polarization strongly couples with the nuclear spin polarization. Finally, the experiments verified the above conclusions. In conclusion, this paper provides theoretical and experimental support for analyzing and suppressing the effect of stochastic magnetic field noise on the SERF co‐magnetometer, which is of great significance for improving the sensitivity and stability of the measurement.
A single-beam spin-exchange relaxation-free atomic magnetometer is ultra-sensitive in the zero field, which has great potential for the detection of a magnetoencephalogram. The addition of a modulated magnetic field is an important approach to achieve high sensitivity for devices of this kind. In this study, we discovered that the amplitude and frequency of the modulated magnetic field (modulation index 0–3) both influence the light absorption. We defined this effect into a function by combining theoretical analysis and the results of experiments. It is discovered that the transmission intensity decreases with an increase in the modulation index. This effect is weakened under the application of a high modulation index. In addition, the transmission intensity and bias magnetic field no longer follow a strict Lorentz curve, while a high degree of fit can be achieved by applying the numerical solution of the Bloch function. A compact magnetometer with a volume of 10 cm3 and a sensitivity of 20 fT/Hz is developed based on the single beam scheme for the proof of concept. Our study is crucial in two aspects: (1) Obtaining high sensitivity through a short measurement period and (2) alignment of the scale factor of the individual magnetometer in a detection array, which further pave the way for improvement in a magnetometer’s performance under a variety of optics platforms.
Magnetic field gradients affect numerous modern sensitive measurements and physics studies using atomic ensemble, resulting in the loss of coherence. In some cases, the presence of small gradients can reduce the performance significantly. In this study, we propose an effectivein situmethod to compensate the triaxial magnetic field gradient for atomic magnetometers, based on multichannel atomic signals in one vapor cell. We design two novel gradient coils by solving closed-form equations to improve the accuracy and efficiency of compensation. We demonstrate the performance of the compensation method in a spin-exchange relaxation-free atomic magnetometer, which reduces the magnetic linewidth by 4.2%–7.6% under the same conditions at a compensation resolution of 50 pT/cm. The proposed coils generate gradients only along two axes and achieve triaxial decoupling, which compensates for the gradient completely without iteration. Our results may aid in suppressing atomic spin relaxations due to magnetic field gradients in several modern measurements and improve their performance, such as the detection of electric dipole moments, ultralow-field nuclear magnetic resonance, and biomagnetism.