IEEE Transactions on Microwave Theory and Techniques

A 1.3-THz Balanced Waveguide HEB Mixer for the APEX Telescope

Denis Meledin, Alexey Pavolotsky, Vincent Desmaris, Igor Lapkin, Christophe Risacher, V. Perez, Doug W. Henke, Olle Nyström, E. Sundin, Dimitar Dochev, Miroslav G. Pantaleev, Mathias Fredrixon, Magnus Strandberg, B. Voronov, Gregory N Gol'tsman, Victor Y. Belitsky

Published Dec 18, 2008• 101 citations
Publisher

Abstract

In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90$\,\times\,$180$\mu{\hbox{m}}$). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light” at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s.

DOI
10.1109/tmtt.2008.2008946

Related papers

A 1-THz Superconducting Hot-Electron-Bolometer Receiver for Astronomical Observations

Denis Meledin, Daniel P. Marrone, Edward Tong +9 more

In this paper, we describe a superconducting hot-electron-bolometer mixer receiver developed to operate in atmospheric windows between 800-1300 GHz. The receiver uses a waveguide mixer element made of 3-4-nm-thick NbN film deposited over crystalline quartz. This mixer yields double-sideband receiver noise temperatures of 1000 K at around 1.0 THz, and 1600 K at 1.26 THz, at an IF of 3.0 GHz. The receiver was successfully tested in the laboratory using a gas cell as a spectral line test source. It is now in use on the Smithsonian Astrophysical Observatory terahertz test telescope in northern Chile.

IEEE Transactions on Microwave Theory and Techniques•Oct 1, 2004•37 citations

2.7 THz Balanced Waveguide HEB Mixer

Faouzi M. Boussaha, Jonathan H. Kawamura, J. A. Stern +1 more

We report on the development of a waveguide-based balanced superconducting mixer for operation near 2.7 THz. The mixer employs a pair of NbN hot-electron bolometers defined on 6 μm-thick silicon substrate that follows a 90°hybrid coupler. To produce the critical structures of the coupler and waveguide embedding circuit, we have utilized silicon micromachining techniques based on deep reactive ion etching. Operating near 4.2 K bath temperature, we have measured a minimum uncorrected DSB receiver noise temperature of less than 2000 K using Callen-Welton formula and local oscillator sideband noise rejection better than 13±3 dB at 2.74 THz. The concept is suitable for building arrays, readily scalable for higher frequencies up 5 THz, and could accommodate other mixer technologies, such as room-temperature Schottky diode mixers.

IEEE Transactions on Terahertz Science and Technology•Jul 30, 2014•23 citations

Terahertz-frequency waveguide NbN hot-electron bolometer mixer

Jonathan H. Kawamura, Edward Tong, R. Blundell +5 more

We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•24 citations

Reduced Noise Temperatures of a THz NbN Hot Electron Bolometer Mixer

B. Mirzaei, J. R. G. Silva, W. J. Vreeling +3 more

In this article, we measure the double sideband (DSB) receiver noise temperature ($T_{\text{rec}}^{\text{DSB}})$of an NbN hot electron bolometer (HEB) mixer at three local oscillator frequencies of 1.6, 2.5, and 5.3 THz. The HEB has cleaned contact interfaces with a 200-nm-thick Au layer. The measured$T_{\text{rec}}^{\text{DSB}}$values are 530 ± 11 K, 640 ± 18 K, and 2190 ±150 K at 1.6, 2.5, and 5.3 THz, respectively, using an air setup with total optical losses of 2.60 ± 0.04, 2.63 ± 0.16, and 4.70 ± 0.24 dB, respectively. We derived low mixer noise temperatures ($T_{\text{mixer}}^{\text{DSB}})$of 240 ± 6 K at 1.6 THz and 290 ± 13 K at 2.5 THz, achieving over 30% improvement compared to published NbN HEB mixers. This enhancement can reduce the integration time of a heterodyne instrument by roughly a factor of 2. At 5.3 THz,$T_{\text{mixer}}^{\text{DSB}}$is 620 ± 55 K, showing limited improvement due to nonoptimized antenna geometry. These results also contribute to understanding the device physics of a wide HEB (4 μm) at high frequencies. The mixer was developed for the proposed Orbiting Astronomical Satellite for Investigating Stellar Systems and Single Aperture Large Telescope for Universe Studies (concept) missions.

IEEE Transactions on Terahertz Science and Technology•Oct 7, 2024•5 citations

NbN Hot Electron Bolometric Mixers for a Quasi--Optical THz Receiver

M. Kroug

Experimental work on the development of a quasi-optical heterodyne receiver for the THz frequency range is reported. The mixing device is a superconducting hot electron bolometer (HEB) made from ultrathin, d = 3 - 5 nm, niobium nitride (NbN) films. Work described in this thesis comprises: The design of a prototype receiver using quasi-optical coupling. Device fabrication involving reactive magnetron sputtering of NbN films and lithographic definition of the antenna integrated mixer. An investigation of the receiver performance at frequencies between 0.6 THz and 2.5 THz. The best performance is obtained with HEB mixers made from NbN films with a thickness d = 3-3.5 nm and a critical temperature T c = 9 - 9.5 K. Double-side band receiver noise temperatures are 530 K at 0.6 THz, 650 K at 1.6 THz and 1100 K at 2.5 THz. Corrected for losses in the receiver input optics, these values amount to only 10 times the theoretical quantum limit. MgO as the substrate material has been shown to provide improved acoustic coupling between NbN film and the substrate compared to other materials such as Si or sapphire. A maximum IF gain bandwidth of 4.5 GHz has been measured under the same operating conditions which yield lowest noise temperature. The local oscilltor power requirement is ~250 nW absorbed in the bolometer. Quasi-optically coupled HEB mixers have become the device-of-choice for radio astronomical applications in the frequency regime at and above 1 THz.

•Jan 1, 2001•4 citations

The sensitivity and IF bandwidth of waveguide NbN Hot Electron Bolometer Mixer on MgO buffer layers crystalline quartz

Denis Meledin, Edward Tong, R. Blundell +4 more

We have developed and characterized waveguide phonon-cooled NbN Hot Electron Bolometer (FMB) mixers fabricated from a 3-4 nrn thick NbN film deposited on a 200nm thick MgO buffer layer over crystalline quartz. Double side band receiver noise temperatures of 900-1050 K at 1.035 THz, and 1300-1400 K at 1.26 THz have been measured at an intermediate frequency of 1.5 GHz. The intermediate frequency bandwidth, measured at 0.8 THz LO frequency, is 3.2 GHz at the optimal bias point for low noise receiver operation.

Softwaretechnik-Trends•Mar 1, 2002•7 citations
In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90 × \,\times\,×180μm\mu{\hbox{m}}μm). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light” at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s.
In this paper, we describe a superconducting hot-electron-bolometer mixer receiver developed to operate in atmospheric windows between 800-1300 GHz. The receiver uses a waveguide mixer element made of 3-4-nm-thick NbN film deposited over crystalline quartz. This mixer yields double-sideband receiver noise temperatures of 1000 K at around 1.0 THz, and 1600 K at 1.26 THz, at an IF of 3.0 GHz. The receiver was successfully tested in the laboratory using a gas cell as a spectral line test source. It is now in use on the Smithsonian Astrophysical Observatory terahertz test telescope in northern Chile.
We report on the development of a waveguide-based balanced superconducting mixer for operation near 2.7 THz. The mixer employs a pair of NbN hot-electron bolometers defined on 6 μm-thick silicon substrate that follows a 90°hybrid coupler. To produce the critical structures of the coupler and waveguide embedding circuit, we have utilized silicon micromachining techniques based on deep reactive ion etching. Operating near 4.2 K bath temperature, we have measured a minimum uncorrected DSB receiver noise temperature of less than 2000 K using Callen-Welton formula and local oscillator sideband noise rejection better than 13±3 dB at 2.74 THz. The concept is suitable for building arrays, readily scalable for higher frequencies up 5 THz, and could accommodate other mixer technologies, such as room-temperature Schottky diode mixers.
We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.
In this article, we measure the double sideband (DSB) receiver noise temperature (TrecDSB)T_{\text{rec}}^{\text{DSB}})TrecDSB​)of an NbN hot electron bolometer (HEB) mixer at three local oscillator frequencies of 1.6, 2.5, and 5.3 THz. The HEB has cleaned contact interfaces with a 200-nm-thick Au layer. The measuredTrecDSBT_{\text{rec}}^{\text{DSB}}TrecDSB​values are 530 ± 11 K, 640 ± 18 K, and 2190 ±150 K at 1.6, 2.5, and 5.3 THz, respectively, using an air setup with total optical losses of 2.60 ± 0.04, 2.63 ± 0.16, and 4.70 ± 0.24 dB, respectively. We derived low mixer noise temperatures (TmixerDSB)T_{\text{mixer}}^{\text{DSB}})TmixerDSB​)of 240 ± 6 K at 1.6 THz and 290 ± 13 K at 2.5 THz, achieving over 30% improvement compared to published NbN HEB mixers. This enhancement can reduce the integration time of a heterodyne instrument by roughly a factor of 2. At 5.3 THz,TmixerDSBT_{\text{mixer}}^{\text{DSB}}TmixerDSB​is 620 ± 55 K, showing limited improvement due to nonoptimized antenna geometry. These results also contribute to understanding the device physics of a wide HEB (4 μm) at high frequencies. The mixer was developed for the proposed Orbiting Astronomical Satellite for Investigating Stellar Systems and Single Aperture Large Telescope for Universe Studies (concept) missions.
Experimental work on the development of a quasi-optical heterodyne receiver for the THz frequency range is reported. The mixing device is a superconducting hot electron bolometer (HEB) made from ultrathin, d = 3 - 5 nm, niobium nitride (NbN) films. Work described in this thesis comprises: The design of a prototype receiver using quasi-optical coupling. Device fabrication involving reactive magnetron sputtering of NbN films and lithographic definition of the antenna integrated mixer. An investigation of the receiver performance at frequencies between 0.6 THz and 2.5 THz. The best performance is obtained with HEB mixers made from NbN films with a thickness d = 3-3.5 nm and a critical temperature T c = 9 - 9.5 K. Double-side band receiver noise temperatures are 530 K at 0.6 THz, 650 K at 1.6 THz and 1100 K at 2.5 THz. Corrected for losses in the receiver input optics, these values amount to only 10 times the theoretical quantum limit. MgO as the substrate material has been shown to provide improved acoustic coupling between NbN film and the substrate compared to other materials such as Si or sapphire. A maximum IF gain bandwidth of 4.5 GHz has been measured under the same operating conditions which yield lowest noise temperature. The local oscilltor power requirement is ~250 nW absorbed in the bolometer. Quasi-optically coupled HEB mixers have become the device-of-choice for radio astronomical applications in the frequency regime at and above 1 THz.
We have developed and characterized waveguide phonon-cooled NbN Hot Electron Bolometer (FMB) mixers fabricated from a 3-4 nrn thick NbN film deposited on a 200nm thick MgO buffer layer over crystalline quartz. Double side band receiver noise temperatures of 900-1050 K at 1.035 THz, and 1300-1400 K at 1.26 THz have been measured at an intermediate frequency of 1.5 GHz. The intermediate frequency bandwidth, measured at 0.8 THz LO frequency, is 3.2 GHz at the optimal bias point for low noise receiver operation.