Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Performances and progress of a compact pulsed CPT Cs clock

Stéphane Guérandel, Rodolphe Boudot, N. Castagna, Emeric de Clercq, N. Dimarcq, Andr  Clairon

Published Jun 1, 2008• 0 citations
Publisher

Abstract

We report on the development of a compact Cs cell CPT frequency standard operating in the Dicke regime. Combining a double Lambda scheme and a Ramsey interrogation, high contrast fringes whose linewidth depends on the time separating two pulses, are obtained. Compared to the continuous regime, the pulsed interrogation reduces the light shift by a factor 300 and permits to reach frequency stability 10 times better. A frequency stability of 9.10−13at 1 s has already been measured.

DOI
10.1109/cpem.2008.4574654

Related papers

Investigations on continuous and pulsed interrogation for a CPT atomic clock

N. Castagna, Rodolphe Boudot, Stéphane Guérandel +3 more

We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Feb 1, 2009•60 citations

Recent progress on the pulsed CPT Cs clock at SYRTE

Jean-Marie Danet, Olga Kozlova, Stéphane Guérandel +1 more

Recent progress are reported on a compact cesium cell atomic frequency standard based on pulsed Coherent Population Trapping interaction in the Dicke regime. Main short term and long term limiting parameters have been identified. Last improvements have permitted to reach a stability of 7×10-13at 1sec and 2×10-14at 2000 s. The noise characterization process is presented in this article.

European Frequency and Time Forum•Apr 1, 2012•2 citations

Raman–Ramsey Interaction for Coherent Population Trapping Cs Clock

Stéphane Guérandel, T. Zanon-Willette, N. Castagna +4 more

A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of$3.5 \times 10^{-12}t^{-1/2}$is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.

IEEE Transactions on Instrumentation and Measurement•Mar 16, 2007•43 citations

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•86 citations

Pulsed-CPT Cs-Ne microcell atomic clock with frequency stability below 2 × 10 −12 at 10 5 s

Clément Carlé, Moustafa Abdel Hafiz, Shervin Keshavarzi +3 more

We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.

Optics Express•Feb 10, 2023•29 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•6 citations
We report on the development of a compact Cs cell CPT frequency standard operating in the Dicke regime. Combining a double Lambda scheme and a Ramsey interrogation, high contrast fringes whose linewidth depends on the time separating two pulses, are obtained. Compared to the continuous regime, the pulsed interrogation reduces the light shift by a factor 300 and permits to reach frequency stability 10 times better. A frequency stability of 9.10−13at 1 s has already been measured.
We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.
A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of3.5×10−12t−1/23.5 \times 10^{-12}t^{-1/2}3.5×10−12t−1/2is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.