Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Single Ca + Ion Trapping toward Precise Frequency Measurement of the 4 2 S 1/2 - 3 2 D 5/2 Transition

Kouki Matsubara, Y. Li, Masatoshi Kajita, K. Hayasaka, Mizuhiko Hosokawa, S. Urabe

Published Aug 31, 2005• 3 citations
OpenAlex

Abstract

We are proceeding with a development of an optical frequency standard using a 2 S 1/2 – 2 D 5/2 electric quadrupole transition of Ca + ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of <1 x 10 -15 is attainable in measurement of the 2 S 1/2 – 2 D 5/2 transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single 40 Ca + ions to the 2 D 5/2 state. I. I NTRODUCTION The uncertainty of primary frequency standards using Cs atoms reaches around 10 -15 and the inherent limits involved in them are discussed. On the other hand, frequency standards using new materials and methods are proposed for developing more accurate frequency standards. Recently, several groups have measured frequencies of the ionic forbidden transitions in the optical region to apply them to the clock transitions of optical frequency standards [1]. We now proceeds with study on an optical frequency standard using single Ca

Related papers

Single Ca/sup +/ ion trapping toward precise frequency measurement of the 4 /sup 2/S/sub 1/2/ - 3/sup 2/D/sub 5/2/ transition

K. Matsubara, Y. Li, Masatoshi Kajita +3 more

We are proceeding with a development of an optical frequency standard using a2Sfrac12-2D5/2electric quadrupole transition of Ca+ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of-15is attainable in measurement of the2Sfrac12-2D5/2transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single40Ca+ions to the2D5/2state

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 18, 2006•0 citations

Quadrupole Transition Spectrum Measurement of Single Ca+ Ions Toward Optical Frequency Standards

Kensuke Matsubara, Ying Li, Kyoya Fukuda +6 more

The National Institute of Information and Communications Technology in Japan is proceeding with development of an optical frequency standard using an electric quadrupole transition of Ca+ ions in a small radio-frequency trap. The single, trapped 40Ca+ ions are laser cooled to a temperature of <10 mK using extended-cavity diode lasers at 397 nm and 866 nm. In order to measure the electric quadrupole transition, the linewidth of the clock laser diode at 729 nm is reduced to ~66 Hz using an ultra-low-expansion (ULE) cavity. We observed the electric quadrupole transition with a linewidth of ~600 kHz, together with the ionic motional sidebands. We are also developing optical frequency combs without photonic fibers broadening the spectrum. The experimental is now improved in order to observe the narrower linewidth of the quadrupole transition.

•Dec 9, 2006•1 citation

Evaluation of the systematic shifts of a single- 40 Ca + -ion frequency standard

Yao Huang, Qu Liu, Jian Zhong Cao +5 more

Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped ${}^{40}$Ca${}^{+}$ with a ``clock'' transition at 729 nm. The overall systematic uncertainty of the 4$s$ ${}^{2}$$\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}$-3$d$ ${}^{2}$$\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}$ clock resonance has been characterized to be 7.8 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}16}$. This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the ${}^{40}$Ca${}^{+}$ clock exceeds that of Cs.

Physical Review A•Nov 21, 2011•36 citations

Cs-Based Frequency Measurement of a Single, Trapped Ion Transition in the Visible Region of the Spectrum

J. E. Bernard, Alan A. Madej, L. Marmet +3 more

An optical frequency chain referenced to a Cs atomic clock has been used to measure directly the frequency of the electric quadrupole allowed $5s^{2}S_{1/2}\ensuremath{-}4d^{2}D_{5/2}$ transition at 445 THz in a single, trapped, and laser cooled ${}^{88}{\mathrm{Sr}}^{+}$ ion. A transition frequency, ${f}_{S\ensuremath{-}D}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}444779044095.4\mathrm{kHz}$ with an estimated standard uncertainty of 0.2 kHz has been determined. Intrinsic offsets of the probed ion transition in the current experiment are calculated to be at the ${10}^{\ensuremath{-}15}$ level.

Physical Review Letters•Apr 19, 1999•148 citations

Prospect of optical frequency standard based on a Ca+43 ion

Masatoshi Kajita, Ying Li, Kensuke Matsubara +2 more

An optical frequency standard based on the $S\text{\ensuremath{-}}D$ transition of trapped $^{43}\mathrm{Ca}^{+}$ is possible by using just laser diodes for cooling and probing. We discuss two open problems related to the feasibility of this frequency standard, the attainable frequency uncertainty and the method of initial-state preparation. The uncertainty of the clock transition frequency can be so small as $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$. Using a laser system consisting of three lasers at different detunings and polarizations, the ion can be cooled down to the Lamb-Dicke regime and then prepared in the $m=0$ state within a period much shorter than the cooling period without being heated. The details of our numerical simulation are described.

Physical Review A•Oct 20, 2005•49 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations
We are proceeding with a development of an optical frequency standard using a 2 S 1/2 – 2 D 5/2 electric quadrupole transition of Ca + ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of <1 x 10 -15 is attainable in measurement of the 2 S 1/2 – 2 D 5/2 transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single 40 Ca + ions to the 2 D 5/2 state. I. I NTRODUCTION The uncertainty of primary frequency standards using Cs atoms reaches around 10 -15 and the inherent limits involved in them are discussed. On the other hand, frequency standards using new materials and methods are proposed for developing more accurate frequency standards. Recently, several groups have measured frequencies of the ionic forbidden transitions in the optical region to apply them to the clock transitions of optical frequency standards [1]. We now proceeds with study on an optical frequency standard using single Ca
The National Institute of Information and Communications Technology in Japan is proceeding with development of an optical frequency standard using an electric quadrupole transition of Ca+ ions in a small radio-frequency trap. The single, trapped 40Ca+ ions are laser cooled to a temperature of <10 mK using extended-cavity diode lasers at 397 nm and 866 nm. In order to measure the electric quadrupole transition, the linewidth of the clock laser diode at 729 nm is reduced to ~66 Hz using an ultra-low-expansion (ULE) cavity. We observed the electric quadrupole transition with a linewidth of ~600 kHz, together with the ionic motional sidebands. We are also developing optical frequency combs without photonic fibers broadening the spectrum. The experimental is now improved in order to observe the narrower linewidth of the quadrupole transition.
Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped 40{}^{40}40Ca+{}^{+}+ with a ``clock'' transition at 729 nm. The overall systematic uncertainty of the 4sss 2{}^{2}2S1/2\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}S1/2​-3ddd 2{}^{2}2D5/2\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}D5/2​ clock resonance has been characterized to be 7.8 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}16}$. This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the 40{}^{40}40Ca+{}^{+}+ clock exceeds that of Cs.
An optical frequency chain referenced to a Cs atomic clock has been used to measure directly the frequency of the electric quadrupole allowed $5s^{2}S_{1/2}\ensuremath{-}4d^{2}D_{5/2}$ transition at 445 THz in a single, trapped, and laser cooled 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+ ion. A transition frequency, ${f}_{S\ensuremath{-}D}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}444779044095.4\mathrm{kHz}$ with an estimated standard uncertainty of 0.2 kHz has been determined. Intrinsic offsets of the probed ion transition in the current experiment are calculated to be at the ${10}^{\ensuremath{-}15}$ level.
An optical frequency standard based on the $S\text{\ensuremath{-}}D$ transition of trapped 43Ca+^{43}\mathrm{Ca}^{+}43Ca+ is possible by using just laser diodes for cooling and probing. We discuss two open problems related to the feasibility of this frequency standard, the attainable frequency uncertainty and the method of initial-state preparation. The uncertainty of the clock transition frequency can be so small as $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$. Using a laser system consisting of three lasers at different detunings and polarizations, the ion can be cooled down to the Lamb-Dicke regime and then prepared in the m=0m=0m=0 state within a period much shorter than the cooling period without being heated. The details of our numerical simulation are described.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.