Optics Letters

Reducing the first-order Doppler shift in a Sagnac interferometer

S. Hannemann, Edcel John Salumbides, Wim Ubachs

Published Apr 25, 2007• 32 citations
Publisher

Abstract

We demonstrate a technique to reduce first-order Doppler shifts in crossed atomic/molecular and laser beam setups by aligning two counterpropagating laser beams as part of a Sagnac interferometer. Interference fringes on the exit port of the interferometer reveal minute deviations from perfect antiparallelism. Residual Doppler shifts of this method scale with the ratio v/(4d) of the typical atomic/molecular velocity v and the laser beam diameter d. The method is implemented for precision frequency calibration studies at deep-UV wavelengths, both in one- and two-photon excitation schemes: the 6s(2) --> 6s30p(3/2)J=1 line in Yb at 199 nm and the 4p(6) --> 4p(5)p[1/2](0) transition in Kr at lambda=212 nm. The achieved precision of 6 x 10(-10) is limited by the characteristics of the laser system.

DOI
10.1364/ol.32.001381

Related papers

Semiclassical Phase Analysis for a Trapped-Atom Sagnac Interferometer

Zhe Luo, Edward Moan, Charles A. Sackett

A Sagnac atom interferometer can be constructed using a Bose–Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits, with two counterpropagating interferometers allowing many sources of common-mode noise to be excluded. In a perfectly symmetric and harmonic potential, the interferometer output would depend only on the rotation rate of the apparatus. However, deviations from the ideal case can lead to spurious phase shifts. These phase shifts have been theoretically analyzed for anharmonic perturbations up to quartic in the confining potential, as well as angular deviations of the laser beams, timing deviations of the laser pulses, and motional excitations of the initial condensate. Analytical and numerical results show the leading effects of the perturbations to be second order. The scaling of the phase shifts with the number of orbits and the trap axial frequency ratio are determined. The results indicate that sensitive parameters should be controlled at the 10−5 level to accommodate a rotation sensing accuracy of 10−9 rad/s. The leading-order perturbations are suppressed in the case of perfect cylindrical symmetry, even in the presence of anharmonicity and other errors. An experimental measurement of one of the perturbation terms is presented.

arXiv:2103.13996•Atoms•Mar 27, 2021•3 citations

Precision Rotation Sensing Using Atom Interferometry

T. L. Gustavson

A rotation-rate sensor was developed using atom interferometry and the Sagnac effect for matter waves. This device has a short-term sensitivity of 6× 10−10 rad/sec for a 1 second integration time, which is the best publicly reported value to date. It has high intrinsic accuracy because it relies on interactions between atoms and laser light that is stabilized to an atomic transition. Long-term stability is promising and characterization is currently underway. Potential applications include inertial navigation, geophysical studies, and general relativity tests such as verification of the Lense-Thirring and geodetic effects. The principle of operation is as follows: A thermal cesium atomic beam crosses three laser interaction regions where two-photon stimulated Raman transitions between cesium ground states transfer momentum to atoms and divide, deflect, and recombine the atomic wavepackets. Rotation induces a phase shift between the two possible trajectories and causes a change in the detected number of atoms with a particular internal state. Counterpropagating atomic beams form two interferometers using shared lasers for common-mode rejection, and the rotation phase shifts have opposite sign since the phase shift is proportional to the vector velocity of the atoms. Therefore, subtracting or adding the interferometer signals discriminates between rotation and transverse acceleration summed with laser arbitrary phase. Furthermore, in the inertial reference frame of the atoms, rotations Doppler-shift the Raman lasers. Adding Raman frequency shifts to cancel these Doppler-shifts allows operation at an effective zero rotation rate, improving sensitivity and bandwidth. Modulating these frequency shifts facilitates sensitive lock-in detection readout techniques.

•Jan 1, 2000•26 citations

A high resolution anharmonic λ/2 fringe spacing interferometer

Hugues Guillet de Chatellus, Jean Paul Pique

Here we present an interferometer where the fringe spacing is reduced by a factor of two and where the width of a fringe can be extremely narrow, leading to potential applications in very precise displacement measurement. Our interferometer is based on elementary aspects of atomic physics. The laser wavelength is tuned to an atomic transition (i.e. two-fold degenerate two level system). The laser field is initially polarized at 45Aring and sent to a polarizing beam splitter. Vertical and horizontal polarizations experience a relative phase shift and are recombined at the output. We present an experimental demonstration of such an interferometer by exciting a sodium vapour cell on the D1line. The problem posed by the hyperfine structure is solved by exciting the whole Doppler-hyperfine transition by means of a dye frequency-shifted feedback laser delivering a 3 GHz broad and continuous spectrum. Both the lambda/2 periodicity and the anharmonic behaviour have been recorded on the fluorescence signal.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

λ/2 fringe-spacing interferometer

Hugues Guillet de Chatellus, Jean Paul Pique

The precision of interferometry is directly linked to the fringe spacing of the recorded interferogram. Whereas all interferometric devices show a fringe spacing equal to a wavelength of the laser light we present a novel scheme of a two-beam interferometer exhibiting a fringe spacing reduced by a factor of 2; the direct detection of the beat signal is replaced with the monitoring of the fluorescence of a twofold degenerate atomic system resonant with the laser. The lambda/2 fringe spacing in the fluorescence signal is demonstrated with a hot sodium vapor excited by a broadband laser tuned to the D1 line. In the saturation regime, the dark fringes are expected to be extremely narrow, leading to the possibility of nanoscale displacement measurements or atom localization.

Optics Letters•Mar 6, 2009•8 citations

Efficient single-photon frequency conversion using a Sagnac interferometer

Matthew Bradford, Jung‐Tsung Shen

We present a quantum nanophotonic scheme to achieve efficient single-photon frequency conversion. This mechanism is essential for integrated nanophotonics, as it can provide access to frequency regimes in which no single-photon sources are currently available. Moreover, such a device could be used as the basis of a photonic frequency-shift-keyed quantum information scheme. The proposed scheme uses a Sagnac interferometer to exploit quantum interference between two transition pathways in a three-level quantum dot. In the proposed scheme, an input photon induces a complete population state transfer on the Lambda-type quantum dot, causing a frequency shift in the outgoing photon. The Sagnac interferometer is used to put the input photon into a superposition of counterpropagating states which interfere at the quantum dot, providing the necessary quantum interference to make the process efficient. We have developed a real-space theoretical approach and a computationally efficient pseudospectral numerical method to invegtigate the full spatiotemporal dynamics of the scattering process. It is shown that the efficiency of the frequency-conversion process approaches unity in the ideal case, and is greater than 80% even in the presence of realistic dissipation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 21, 2013•6 citations

Precision Atomic Beam Spectroscopy Using Stabilized Lasers.

J. L. Hall

Abstract : The goal of our work has been to investigate a few well-chosen effects in laser spectroscopy under clean experimental conditions which facilitate a sharp and meaningful contact with theory. The initially-defined task was to study large pulse-area effects in single upward transitions from metastable atoms in a fast, monovelocity Ne* beam. It proved possible as well to investigate multiple-pulse transitions on a cw basis. Ramsey fringe resonance signatures were clearly observed and for the first time in the optical domain, using three pulse excitation. Basically the first two zones of light provide initially a coherence and secondly an atomic population in the excited state. The counter-running fields in the second zone and third zones convert excited state population into a coherence again and finally into a nonlinear (with intensity) change in the excited and ground state populations. In view of the time gap tau in the preparation phase, one could anticipate and did observe narrow Ramsey fringes which vary as cos (delta, omega, tau) in the middle of the single zone excitation linewidth function ( Rabbi pedestal ). The neon beam employed was rather fast (v/c approx. .001) and, being produced by charge transfer had an exceptionally an narrow velocity distribution, delta, approx .0001. These characteristics permitted unambiguous measurements of the fringe shapes and facilitated useful contact with theory. A second extremely successful experiment was the combination of laser excitation of two-photon Doppler-free transitions in the 5S yields nS series in Rubidium with precise Lambdameter interferometer techniques to accurately measure the transition wavelength.

•Jun 30, 1985•0 citations
We demonstrate a technique to reduce first-order Doppler shifts in crossed atomic/molecular and laser beam setups by aligning two counterpropagating laser beams as part of a Sagnac interferometer. Interference fringes on the exit port of the interferometer reveal minute deviations from perfect antiparallelism. Residual Doppler shifts of this method scale with the ratio v/(4d) of the typical atomic/molecular velocity v and the laser beam diameter d. The method is implemented for precision frequency calibration studies at deep-UV wavelengths, both in one- and two-photon excitation schemes: the 6s(2) --> 6s30p(3/2)J=1 line in Yb at 199 nm and the 4p(6) --> 4p(5)p1/2 transition in Kr at lambda=212 nm. The achieved precision of 6 x 10(-10) is limited by the characteristics of the laser system.
A Sagnac atom interferometer can be constructed using a Bose–Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits, with two counterpropagating interferometers allowing many sources of common-mode noise to be excluded. In a perfectly symmetric and harmonic potential, the interferometer output would depend only on the rotation rate of the apparatus. However, deviations from the ideal case can lead to spurious phase shifts. These phase shifts have been theoretically analyzed for anharmonic perturbations up to quartic in the confining potential, as well as angular deviations of the laser beams, timing deviations of the laser pulses, and motional excitations of the initial condensate. Analytical and numerical results show the leading effects of the perturbations to be second order. The scaling of the phase shifts with the number of orbits and the trap axial frequency ratio are determined. The results indicate that sensitive parameters should be controlled at the 10−5 level to accommodate a rotation sensing accuracy of 10−9 rad/s. The leading-order perturbations are suppressed in the case of perfect cylindrical symmetry, even in the presence of anharmonicity and other errors. An experimental measurement of one of the perturbation terms is presented.
A rotation-rate sensor was developed using atom interferometry and the Sagnac effect for matter waves. This device has a short-term sensitivity of 6× 10−10 rad/sec for a 1 second integration time, which is the best publicly reported value to date. It has high intrinsic accuracy because it relies on interactions between atoms and laser light that is stabilized to an atomic transition. Long-term stability is promising and characterization is currently underway. Potential applications include inertial navigation, geophysical studies, and general relativity tests such as verification of the Lense-Thirring and geodetic effects. The principle of operation is as follows: A thermal cesium atomic beam crosses three laser interaction regions where two-photon stimulated Raman transitions between cesium ground states transfer momentum to atoms and divide, deflect, and recombine the atomic wavepackets. Rotation induces a phase shift between the two possible trajectories and causes a change in the detected number of atoms with a particular internal state. Counterpropagating atomic beams form two interferometers using shared lasers for common-mode rejection, and the rotation phase shifts have opposite sign since the phase shift is proportional to the vector velocity of the atoms. Therefore, subtracting or adding the interferometer signals discriminates between rotation and transverse acceleration summed with laser arbitrary phase. Furthermore, in the inertial reference frame of the atoms, rotations Doppler-shift the Raman lasers. Adding Raman frequency shifts to cancel these Doppler-shifts allows operation at an effective zero rotation rate, improving sensitivity and bandwidth. Modulating these frequency shifts facilitates sensitive lock-in detection readout techniques.
Here we present an interferometer where the fringe spacing is reduced by a factor of two and where the width of a fringe can be extremely narrow, leading to potential applications in very precise displacement measurement. Our interferometer is based on elementary aspects of atomic physics. The laser wavelength is tuned to an atomic transition (i.e. two-fold degenerate two level system). The laser field is initially polarized at 45Aring and sent to a polarizing beam splitter. Vertical and horizontal polarizations experience a relative phase shift and are recombined at the output. We present an experimental demonstration of such an interferometer by exciting a sodium vapour cell on the D1line. The problem posed by the hyperfine structure is solved by exciting the whole Doppler-hyperfine transition by means of a dye frequency-shifted feedback laser delivering a 3 GHz broad and continuous spectrum. Both the lambda/2 periodicity and the anharmonic behaviour have been recorded on the fluorescence signal.
The precision of interferometry is directly linked to the fringe spacing of the recorded interferogram. Whereas all interferometric devices show a fringe spacing equal to a wavelength of the laser light we present a novel scheme of a two-beam interferometer exhibiting a fringe spacing reduced by a factor of 2; the direct detection of the beat signal is replaced with the monitoring of the fluorescence of a twofold degenerate atomic system resonant with the laser. The lambda/2 fringe spacing in the fluorescence signal is demonstrated with a hot sodium vapor excited by a broadband laser tuned to the D1 line. In the saturation regime, the dark fringes are expected to be extremely narrow, leading to the possibility of nanoscale displacement measurements or atom localization.
We present a quantum nanophotonic scheme to achieve efficient single-photon frequency conversion. This mechanism is essential for integrated nanophotonics, as it can provide access to frequency regimes in which no single-photon sources are currently available. Moreover, such a device could be used as the basis of a photonic frequency-shift-keyed quantum information scheme. The proposed scheme uses a Sagnac interferometer to exploit quantum interference between two transition pathways in a three-level quantum dot. In the proposed scheme, an input photon induces a complete population state transfer on the Lambda-type quantum dot, causing a frequency shift in the outgoing photon. The Sagnac interferometer is used to put the input photon into a superposition of counterpropagating states which interfere at the quantum dot, providing the necessary quantum interference to make the process efficient. We have developed a real-space theoretical approach and a computationally efficient pseudospectral numerical method to invegtigate the full spatiotemporal dynamics of the scattering process. It is shown that the efficiency of the frequency-conversion process approaches unity in the ideal case, and is greater than 80% even in the presence of realistic dissipation.
Abstract : The goal of our work has been to investigate a few well-chosen effects in laser spectroscopy under clean experimental conditions which facilitate a sharp and meaningful contact with theory. The initially-defined task was to study large pulse-area effects in single upward transitions from metastable atoms in a fast, monovelocity Ne* beam. It proved possible as well to investigate multiple-pulse transitions on a cw basis. Ramsey fringe resonance signatures were clearly observed and for the first time in the optical domain, using three pulse excitation. Basically the first two zones of light provide initially a coherence and secondly an atomic population in the excited state. The counter-running fields in the second zone and third zones convert excited state population into a coherence again and finally into a nonlinear (with intensity) change in the excited and ground state populations. In view of the time gap tau in the preparation phase, one could anticipate and did observe narrow Ramsey fringes which vary as cos (delta, omega, tau) in the middle of the single zone excitation linewidth function ( Rabbi pedestal ). The neon beam employed was rather fast (v/c approx. .001) and, being produced by charge transfer had an exceptionally an narrow velocity distribution, delta, approx .0001. These characteristics permitted unambiguous measurements of the fringe shapes and facilitated useful contact with theory. A second extremely successful experiment was the combination of laser excitation of two-photon Doppler-free transitions in the 5S yields nS series in Rubidium with precise Lambdameter interferometer techniques to accurately measure the transition wavelength.