Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

A fully functional Ramsey-CPT atomic clock

Qun Zhou, Chao Guan, Xiaosong Zhu, Yeqing Li

Published May 1, 2011• 1 citation
Publisher

Abstract

The abstract presents a fully functional Ramsey-CPT atomic clock, which has the characteristics of compact structure, small volume, low cost, strong adaptability, high stability, convenient for adjustment, unique design, and easy-to-commercialization. The Ramsey-CPT atomic clock combines the method of separated oscillatory fields and the phenomenon of coherent population trapping, so as to obtain narrower line width and better signal-to-noise ratio of the resonance signal for improving the frequency stability. It not only keeps the advantages of miniaturization and low power of the CPT atomic clock, but also can obtain higher frequency stability than CPT atomic clock about one order of magnitude.

DOI
10.1109/fcs.2011.5977803

Related papers

A subminiature adjustable and measurable atomic clock based on coherent population trapping

Xiaosong Zhu, Chao Guan, Qun Zhou

Based on the operating principle and the comprehensive analysis of the coherent population trapping (CPT) atomic clock system, the paper presents an appropriate physics package and design a small and digital servo circuit system, forming a subminiature adjustable and measurable CPT atomic clock system which uses vertical-cavity surface-emitting laser (VCSEL) as optical source, selects85Rb as operating atoms, and is in resonance with the D1transitions. The system can be used for experimental study of correlation of each parameter and study of the Ramsey-CPT atomic clock. The whole system, which adequately combines the advantages of the ordinary desktop CPT experimental system and the chip-scale atomic clock (CSAC), is compact, small, low-power and well-adapted, in line with the further requirements of commercial development.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2011•1 citation

A design and implementation of miniature CPT atomic clock based on ~(85)Rb

Duan We

A Coherent Population Trapping(CPT) atomic clock servo control circuit is designed based on the CPT phenomenon of 85 Rb. Taking MSP430 chip as a platform, combining with the physical device made up of Vecsel laser, photoelectric detector, and small 85 Rb vapor cell, a miniature atomic clock with the high-performance, high stability, low power consumption and small size is implemented. The volume is 31 cm3 and the power consumption is 660 m W. The frequency stability of 10 MHz measured is 2×10-10/s, 4×10-11/1 000 s. Full-hyperfine-splitting frequency modulation is used to improve the frequency stability.

Tai Hezi Kexue Yudianzi Xinxi Xuebao•Jan 1, 2015•0 citations

Frequency Stability of Atomic Clocks Based on Coherent Population Trapping Resonance in 85 Rb

Lu Liu, Guo Tao, Ke Deng +3 more

An atomic clock system based on coherent population trapping (CPT) resonance in 85 Rb is reported, while most past works about the CPT clock are in 87 Rb. A new modulation method (full-hyperfine-frequency-splitting modulation) is presented to reduce the effect of light shift to improve the frequency stability of the CPT clock in 85 Rb. The experimental results show that the short-term frequency stability of the CPT clock in 85 Rb is in the order of 10 −10 /s and the long-term frequency stability can achieve 1.5 × 10 −11 /80000 s, which performs as well as 87 Rb in CPT resonance. This very good frequency stability performance associated with the low-cost and low-power properties of 85 Rb indicates that an atomic clock based on CPT in 85 Rb should be a promising candidate for making the chip scale atomic clock.

Chinese Physics Letters•Jun 28, 2007•9 citations

Compact atomic clock prototype based on coherent population trapping

Jean-Marie Danet, Olga Kozlova, Peter Yun +2 more

Toward the next generations of compact atomic clocks, clocks based on coherent population trapping (CPT) offer a very interesting alternative. Thanks to CPT, a quantum interfering process, this technology has made a decisive step in the miniaturization direction. Fractional frequency stability of 1.5x10-10 at 1 s has been demonstrated in commercial devices of a few cm3. The laboratory prototype presented here intends to explore what could be the ultimate stability of a CPT based device. To do so, an original double-Λ optical scheme and a pulsed interrogation have been implemented in order to get a good compromise between contrast and linewidth. A study of two main sources of noise, the relative intensity and the local oscillator (LO) noise, has been performed. By designing simple solutions, it led to a new fractional frequency limitation lower than 4x10-13 at 1 s integration. Such a performance proves that such a technology could rival with classical ones as double resonance clocks.

EPJ Web of Conferences•Aug 19, 2014•31 citations

Operation of a Ramsey-CPT microcell atomic clock with driving current-based power modulation of a VCSEL

C. M. Rivera-Aguilar, Martin Callejo, Andrei Mursa +6 more

We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.

Applied Physics Letters•Mar 11, 2024•10 citations

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan +3 more

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

Chinese Physics B•Oct 6, 2021•8 citations
The abstract presents a fully functional Ramsey-CPT atomic clock, which has the characteristics of compact structure, small volume, low cost, strong adaptability, high stability, convenient for adjustment, unique design, and easy-to-commercialization. The Ramsey-CPT atomic clock combines the method of separated oscillatory fields and the phenomenon of coherent population trapping, so as to obtain narrower line width and better signal-to-noise ratio of the resonance signal for improving the frequency stability. It not only keeps the advantages of miniaturization and low power of the CPT atomic clock, but also can obtain higher frequency stability than CPT atomic clock about one order of magnitude.
Based on the operating principle and the comprehensive analysis of the coherent population trapping (CPT) atomic clock system, the paper presents an appropriate physics package and design a small and digital servo circuit system, forming a subminiature adjustable and measurable CPT atomic clock system which uses vertical-cavity surface-emitting laser (VCSEL) as optical source, selects85Rb as operating atoms, and is in resonance with the D1transitions. The system can be used for experimental study of correlation of each parameter and study of the Ramsey-CPT atomic clock. The whole system, which adequately combines the advantages of the ordinary desktop CPT experimental system and the chip-scale atomic clock (CSAC), is compact, small, low-power and well-adapted, in line with the further requirements of commercial development.
A Coherent Population Trapping(CPT) atomic clock servo control circuit is designed based on the CPT phenomenon of 85 Rb. Taking MSP430 chip as a platform, combining with the physical device made up of Vecsel laser, photoelectric detector, and small 85 Rb vapor cell, a miniature atomic clock with the high-performance, high stability, low power consumption and small size is implemented. The volume is 31 cm3 and the power consumption is 660 m W. The frequency stability of 10 MHz measured is 2×10-10/s, 4×10-11/1 000 s. Full-hyperfine-splitting frequency modulation is used to improve the frequency stability.
An atomic clock system based on coherent population trapping (CPT) resonance in 85 Rb is reported, while most past works about the CPT clock are in 87 Rb. A new modulation method (full-hyperfine-frequency-splitting modulation) is presented to reduce the effect of light shift to improve the frequency stability of the CPT clock in 85 Rb. The experimental results show that the short-term frequency stability of the CPT clock in 85 Rb is in the order of 10 −10 /s and the long-term frequency stability can achieve 1.5 × 10 −11 /80000 s, which performs as well as 87 Rb in CPT resonance. This very good frequency stability performance associated with the low-cost and low-power properties of 85 Rb indicates that an atomic clock based on CPT in 85 Rb should be a promising candidate for making the chip scale atomic clock.
Toward the next generations of compact atomic clocks, clocks based on coherent population trapping (CPT) offer a very interesting alternative. Thanks to CPT, a quantum interfering process, this technology has made a decisive step in the miniaturization direction. Fractional frequency stability of 1.5x10-10 at 1 s has been demonstrated in commercial devices of a few cm3. The laboratory prototype presented here intends to explore what could be the ultimate stability of a CPT based device. To do so, an original double-Λ optical scheme and a pulsed interrogation have been implemented in order to get a good compromise between contrast and linewidth. A study of two main sources of noise, the relative intensity and the local oscillator (LO) noise, has been performed. By designing simple solutions, it led to a new fractional frequency limitation lower than 4x10-13 at 1 s integration. Such a performance proves that such a technology could rival with classical ones as double resonance clocks.
We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.