Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Comparison of achievable performances as regards rubidium gas cell frequency standards with continuous and pulse laser pumping and with coherent population trapping

V. S. Zholnerov, A. Besedina, Georgy A. Kazakov

Published Apr 1, 2009• 1 citation
Publisher

Abstract

We report the results of mathematical modeling the frequency stability for three types of rubidium gas cell frequency standards : with continuous and pulse laser pumping and with coherent population trapping (CPT). A critical point for using laser pumping in RFS which defines essentially the frequency stability is the influence of laser emission's frequency fluctuations. The effect of these fluctuations on frequency stability of RFS variants' considered is analyzed. Based on studies performed, the achievable stability for these RFS variants are compared.

DOI
10.1109/freq.2009.5168250

Related papers

Potential for improving the rubidium frequency standard with a novel optical pumping scheme using diode lasers

Natarajan D. Bhaskar

It is experimentally demonstrated that, using diode lasers for optical pumping and RF /spl pi/-pulses for population transfer, nearly all of the ground state Rb atoms in a vapor cell can be concentrated into one of the two M/sub F/ = 0 sublevels. The fractional population difference /spl Delta/ between the two M/sub F/ = 0 levels can be made as high as 1. This should result in a very significant improvement (about a factor of 100) in the S/N over the conventional discharge-lamp-pumped rubidium frequency standards (RFSs). This would lead to a substantial improvement in the short-term stability of the RFS. This is a pulsed population transfer scheme. The microwave interrogation takes place in the absence of strong pumping light. This has the potential for eliminating the light shift and thereby improving the long-term frequency stability of a an RFS.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 30, 2002•0 citations

Rubidium frequency standard with two-frequency laser pumping scheme

Georgy A. Kazakov, Boris G. Matisov

In this paper we compare two different excitation schemes of rubidium gas-cell frequency standard. We provide the stability estimations for one-frequency and two-frequency pumping schemes. Our calculations show the significant improvement of stability in the case of two-frequency scheme. It concerned with the absence of 'pockets' ('trap' states) and therefore with more efficient population collection on one of the working sublevels for two-pumping scheme.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 3, 2006•0 citations

Optimization of laser radiation for CPT-based miniature frequency standard

К. А. Баранцев, A. N. Litvinov, Evgeniy Popov +1 more

The present work is dedicated to optimization of the laser radiation parameters and optically thickness of the gas cell for improvement of short-term stability of quantum frequency standard based on coherent population trapping effect in the cell with 87Rb working gas and buffer gas. The effects associated with the optical density of the medium are investigated, such as laser spectrum distortion and appearance of the light shifts of the coherent population trapping resonance due to different absorption of frequency components.

European Frequency and Time Forum•Apr 1, 2016•2 citations

Investigations on continuous and pulsed interrogation for a CPT atomic clock

N. Castagna, Rodolphe Boudot, Stéphane Guérandel +3 more

We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Feb 1, 2009•60 citations

Nitrogen-Pressure Dependence of Coherent Population Trapping Signal Characteristics in Microfabricated Rubidium Vapor Cells

Shun Kiyose, Masahiro Fukuoka, Yusuke Odagiri +4 more

Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N ${}_{2}$ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN ${}_{3}$ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.

IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control•Jan 1, 2026•0 citations

Potential for improving the Rubidium Frequency Standard with a novel optical pumping scheme using diode lasers

Natarajan D. Bhaskar

Frequency stability of a Rubidium Frequency Standard (RFS) is directly related to the signal-to-noise ratio (S/N) of the microwave-induced (6834 MHz) optical signal which is proportional to the fractional atomic population difference between the two M/sub F/=0 ground state sublevels of /sup 87/Rb. In the present RFSs this fractional population difference is small (>

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jan 1, 1995•17 citations
We report the results of mathematical modeling the frequency stability for three types of rubidium gas cell frequency standards : with continuous and pulse laser pumping and with coherent population trapping (CPT). A critical point for using laser pumping in RFS which defines essentially the frequency stability is the influence of laser emission's frequency fluctuations. The effect of these fluctuations on frequency stability of RFS variants' considered is analyzed. Based on studies performed, the achievable stability for these RFS variants are compared.
It is experimentally demonstrated that, using diode lasers for optical pumping and RF /spl pi/-pulses for population transfer, nearly all of the ground state Rb atoms in a vapor cell can be concentrated into one of the two M/sub F/ = 0 sublevels. The fractional population difference /spl Delta/ between the two M/sub F/ = 0 levels can be made as high as 1. This should result in a very significant improvement (about a factor of 100) in the S/N over the conventional discharge-lamp-pumped rubidium frequency standards (RFSs). This would lead to a substantial improvement in the short-term stability of the RFS. This is a pulsed population transfer scheme. The microwave interrogation takes place in the absence of strong pumping light. This has the potential for eliminating the light shift and thereby improving the long-term frequency stability of a an RFS.>
The present work is dedicated to optimization of the laser radiation parameters and optically thickness of the gas cell for improvement of short-term stability of quantum frequency standard based on coherent population trapping effect in the cell with 87Rb working gas and buffer gas. The effects associated with the optical density of the medium are investigated, such as laser spectrum distortion and appearance of the light shifts of the coherent population trapping resonance due to different absorption of frequency components.
We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.
Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N 2{}_{2}2​ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN 3{}_{3}3​ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.