Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Limits in wavelength measurement of optical signals

David J. F. Cooper, Peter W. E. Smith

Published Apr 29, 2004• 11 citations
Publisher

Abstract

We determine the maximum accuracy in the wavelength measurement of finite-bandwidth optical signals. The limit is dependent on the spectral and coherence properties of the optical signal and on the available optical power. We also investigate the effect of finite measurement resolution in the wavelength measurement.
DOI
10.1364/josab.21.000908

Related papers

Fundamental limits to the wavelength measurement of optical signals

David J. F. Cooper, P. W. E. Smith

The fundamental limits for measuring the wavelength of optical signals is derived. The analysis provides a lower bound for any measurement apparatus. It is found that the lower limit depends on the optical power available for measurement, the statistical properties of the measured light and on the spectral distribution of the signal. Experimental measurements performed by the authors and presented by others are consistent with the limit.

IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS)•Aug 23, 2004•1 citation

Quantum Limit to Precision of Wavelength Determination

G. R. Hanes

The precision of wavelength determination is ultimately limited by noise arising from the quantum nature of light and light detection. Expressions are derived for the limiting precision attainable by various interferometers and conventional spectrometers in terms of parameters characterizing the instruments, the source, and the detector. A comparison of five different instruments shows the superiority of the interferometers and indicates that they are divided into three classes, according to the role played by the half-width of the radiation from the source.

Applied Optics•May 1, 1963•9 citations

Coherent detection of weak signals with superconducting nanowire single photon detector at the telecommunication wavelength

Michael Shcherbatenko, Y. Lobanov, Alexander V. Semenov +6 more

Achievement of the ultimate sensitivity along with a high spectral resolution is one of the frequently addressed problems, as the complication of the applied and fundamental scientific tasks being explored is growing up gradually. In our work, we have investigated performance of a superconducting nanowire photon-counting detector operating in the coherent mode for detection of weak signals at the telecommunication wavelength. Quantum-noise limited sensitivity of the detector was ensured by the nature of the photon-counting detection and restricted by the quantum efficiency of the detector only. Spectral resolution given by the heterodyne technique and was defined by the linewidth and stability of the Local Oscillator (LO). Response bandwidth was found to coincide with the detector’s pulse width, which, in turn, could be controlled by the nanowire length. In addition, the system noise bandwidth was shown to be governed by the electronics/lab equipment, and the detector noise bandwidth is predicted to depend on its jitter. As have been demonstrated, a very small amount of the LO power (of the order of a few picowatts down to hundreds of femtowatts) was required for sufficient detection of the test signal, and eventual optimization could lead to further reduction of the LO power required, which would perfectly suit for the foreseen development of receiver matrices and the need for detection of ultra-low signals at a level of less-than-one-photon per second.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 2017•0 citations

II Quantum Mechanical Limit in Optical Precision Measurement and Communication

Y. Yamamoto, S. Machida, Shigeru Saito +4 more

Progress in optics•Jan 1, 1990•36 citations

Squeezing-enhanced heterodyne detection of 10 Hz atto-Watt optical signals

Boya Xie, Sheng Feng

A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.

Optics Letters•Dec 12, 2018•23 citations

Nonlinear transmission of an optical signal

Adrian C. Selden

The dependence of phase and modulation depth on the frequency and intensity of an optical signal is examined for the case of transmission by a saturable absorber.

Electronics Letters•Jun 3, 1971•7 citations
The precision of wavelength determination is ultimately limited by noise arising from the quantum nature of light and light detection. Expressions are derived for the limiting precision attainable by various interferometers and conventional spectrometers in terms of parameters characterizing the instruments, the source, and the detector. A comparison of five different instruments shows the superiority of the interferometers and indicates that they are divided into three classes, according to the role played by the half-width of the radiation from the source.
Achievement of the ultimate sensitivity along with a high spectral resolution is one of the frequently addressed problems, as the complication of the applied and fundamental scientific tasks being explored is growing up gradually. In our work, we have investigated performance of a superconducting nanowire photon-counting detector operating in the coherent mode for detection of weak signals at the telecommunication wavelength. Quantum-noise limited sensitivity of the detector was ensured by the nature of the photon-counting detection and restricted by the quantum efficiency of the detector only. Spectral resolution given by the heterodyne technique and was defined by the linewidth and stability of the Local Oscillator (LO). Response bandwidth was found to coincide with the detector’s pulse width, which, in turn, could be controlled by the nanowire length. In addition, the system noise bandwidth was shown to be governed by the electronics/lab equipment, and the detector noise bandwidth is predicted to depend on its jitter. As have been demonstrated, a very small amount of the LO power (of the order of a few picowatts down to hundreds of femtowatts) was required for sufficient detection of the test signal, and eventual optimization could lead to further reduction of the LO power required, which would perfectly suit for the foreseen development of receiver matrices and the need for detection of ultra-low signals at a level of less-than-one-photon per second.
A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.