Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Electronics and Laser Science Conference

Quantum imaging of nonlocal spatial correlations in parametric down-conversion induced by the pump-beam profile

Kahraman G. Köprülü, G.A. Barbosa, Prem Kumar

Published Dec 10, 2005• 1 citation
Publisher

Abstract

We present a quantum imaging method wherein the quantum image obtained through coincidence counting is dependent on the pump-beam profile. Quantum nature of the nonlocal spatial correlations are experimentally verified.
DOI
10.1109/qels.2005.1548721

Related papers

Quantum Imaging of Nonlocal Spatial Correlations Induced by Orbital Angular Momentum

Adam R. Altman, Kahraman G. Köprülü, Eric Corndorf +2 more

Through scanned coincidence counting, we probe the quantum image produced by parametric down-conversion with a pump-beam carrying orbital angular momentum. Nonlocal spatial correlations are manifested through splitting of the coincidence spot into two.

arXiv:quant-ph/0409180•Physical Review Letters•Mar 29, 2005•51 citations

Some topics in Quantum Imaging

Luigi A. Lugiato, A. Gatti, E. Brambilla +5 more

Abstract. The field of Quantum Imaging exploits the quantum nature of light and the intrinsic parallelism of optical signals to devise novel techniques for optical imaging and for parallel information processing at the quantum level (see [1] and references quoted therein). In this presentation, we will shortly discuss two topics in this area: the first is the so-called ghost imaging which, however, is not necessarily quantum; the second is the detection of faint amplitude objects with a sensitivity beyond the standard quantum limit, and in this case we are fully in the quantum domain. Both topics are related to the phenomenon of optical parametric down-conversion (PDC), in which a fraction of the pump photons of a laser beam, injected into a crystal with a quadratic non-linearity, are down-converted to a pair of signal and idler photons, with conservation of total energy and total momentum. A feature of paramount importance is that the signal and idler beams are spatially correlated both in the near field (position correlation) and in the far field (momentum correlation).The simultaneous presence of position and momentum correlation implies quantum entanglement, as it has been also observed experimentally [2]. 1. Ghost Imaging

Journal of Physics Conference Series•Feb 1, 2010•0 citations

Interference effects induced by non-local spatial filtering

Stephen Patrick Walborn, P. H. Souto Ribeiro, Carlos Henrique Monken

The spatial correlation between down-converted photons allows for non-local spatial filtering when two-photon coincidences are registered. This allows one to non-locally control the visibility of interference fringes, to observe ghost images and interference patterns, and to "retrieve" a coherent quantum image from an incoherent field distribution. We show theoretically that non-local spatial filtering can lead to counter-intuitive effects when the pump beam is no longer given by a Gaussian profile. Namely, increased non-local filtering can actually decrease the visibility of interference fringes, contrary to what has been observed so far. We explain this behavior through the transverse spatial parity entanglement of the down-converted photons.

Optics Express•Aug 18, 2011•5 citations

Natural and man-made in quantum imaging

Luigi A. Lugiato, Jean-Luc Blanchet, E. Brambilla +6 more

As in the case of quantum information and communication, in the field of quantum imaging entanglement represents an invaluable resource. Processes such as parametric down-conversion (PDC) and four-wave mixing provide natural sources of quantum entangled beams endowed with spatial entanglement properties that are useful in quantum imaging. The authors will review these well known features in the case of PDC, and the technique which allows for an imaging with a sensitivity beyond the standard quantum limit, which has been theoretically predicted and experimentally demonstrated.

IEEE/LEOS Summer Topical Meetings•Jul 1, 2011•0 citations

Exploiting PDC spatial correlations for innovative quantum imaging protocols

Marco Genovese, G. Brida, Alice Meda +1 more

Quantum properties of the optical field represent a resource of the utmost relevance for the development of quantum technologies, allowing unprecedented results in disciplines ranging from quantum information and metrology to quantum imaging. Spatial quantum correlations generated by of parametric down conversion (PDC) represents a tool for quantum imaging because they are intrinsically multimode, a requirement for obtaining large degree of correlation over small portions of the beams, allowing to register the spatial structure of an object. In particular a very interesting example is provided by the detection of weak objects, a result that could have important practical applications. The principle of this technique is to take advantage of the correlation in the noise of two conjugated branches of PDC emission: in fact, subtracting the noise measured on one branch from the image of a weak object obtained in the other branch, the image of the object, eventually previously hidden in the noise, could be restored. Here, after a general summary of quantum imaging techniques, firstly we will show how we have reached a sub shot noise regime and then improved this result up to reach a regime where it was possible to achieve the first experimental realisation of sub shot noise imaging of a weak absorbing object.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 16, 2011•1 citation

Optical imaging by means of two-photon quantum entanglement

T. B. Pittman, Yanhua H. Shih, Dmitry Strekalov +1 more

A two-photon optical imaging experiment was performed based on the quantum nature of the signal and idler photon pairs produced in spontaneous parametric down-conversion. An aperture placed in front of a fixed detector is illuminated by the signal beam through a convex lens. A sharp magnified image of the aperture is found in the coincidence counting rate when a mobile detector is scanned in the transverse plane of the idler beam at a specific distance in relation to the lens.

Physical Review A•Nov 1, 1995•2,327 citations
Abstract. The field of Quantum Imaging exploits the quantum nature of light and the intrinsic parallelism of optical signals to devise novel techniques for optical imaging and for parallel information processing at the quantum level (see [1] and references quoted therein). In this presentation, we will shortly discuss two topics in this area: the first is the so-called ghost imaging which, however, is not necessarily quantum; the second is the detection of faint amplitude objects with a sensitivity beyond the standard quantum limit, and in this case we are fully in the quantum domain. Both topics are related to the phenomenon of optical parametric down-conversion (PDC), in which a fraction of the pump photons of a laser beam, injected into a crystal with a quadratic non-linearity, are down-converted to a pair of signal and idler photons, with conservation of total energy and total momentum. A feature of paramount importance is that the signal and idler beams are spatially correlated both in the near field (position correlation) and in the far field (momentum correlation).The simultaneous presence of position and momentum correlation implies quantum entanglement, as it has been also observed experimentally [2]. 1. Ghost Imaging
The spatial correlation between down-converted photons allows for non-local spatial filtering when two-photon coincidences are registered. This allows one to non-locally control the visibility of interference fringes, to observe ghost images and interference patterns, and to "retrieve" a coherent quantum image from an incoherent field distribution. We show theoretically that non-local spatial filtering can lead to counter-intuitive effects when the pump beam is no longer given by a Gaussian profile. Namely, increased non-local filtering can actually decrease the visibility of interference fringes, contrary to what has been observed so far. We explain this behavior through the transverse spatial parity entanglement of the down-converted photons.
As in the case of quantum information and communication, in the field of quantum imaging entanglement represents an invaluable resource. Processes such as parametric down-conversion (PDC) and four-wave mixing provide natural sources of quantum entangled beams endowed with spatial entanglement properties that are useful in quantum imaging. The authors will review these well known features in the case of PDC, and the technique which allows for an imaging with a sensitivity beyond the standard quantum limit, which has been theoretically predicted and experimentally demonstrated.
Quantum properties of the optical field represent a resource of the utmost relevance for the development of quantum technologies, allowing unprecedented results in disciplines ranging from quantum information and metrology to quantum imaging. Spatial quantum correlations generated by of parametric down conversion (PDC) represents a tool for quantum imaging because they are intrinsically multimode, a requirement for obtaining large degree of correlation over small portions of the beams, allowing to register the spatial structure of an object. In particular a very interesting example is provided by the detection of weak objects, a result that could have important practical applications. The principle of this technique is to take advantage of the correlation in the noise of two conjugated branches of PDC emission: in fact, subtracting the noise measured on one branch from the image of a weak object obtained in the other branch, the image of the object, eventually previously hidden in the noise, could be restored. Here, after a general summary of quantum imaging techniques, firstly we will show how we have reached a sub shot noise regime and then improved this result up to reach a regime where it was possible to achieve the first experimental realisation of sub shot noise imaging of a weak absorbing object.