The European Physical Journal D

Investigation of magneto-optical effect in transverse magnetic field in He

Emilia A. Alipieva, S.I. Karabasheva

Published Jun 1, 1999• 1 citation
Publisher
DOI
10.1007/s100530050311

Related papers

Effect of Transverse Magnetic Fields on Cold-Atom Nonlinear Magneto-Optical Rotation

David H. Meyer, Paul D. Kunz, Fredrik K. Fatemi +1 more

Bulletin of the American Physical Society•May 25, 2016•0 citations

Investigations on Individual Atoms in Magneto-Optical and Magnetic Traps

S. aus-der-Wiesche, B. Ueberholz, Frank Strauch +2 more

European Quantum Electronics Conference (EQEC)•Jan 1, 1996•0 citations

Coherent magneto-optical resonances on the potassium D2 line in modified hanle configuration for magnetometry applications

S. Tsvetkov, C. Andreeva, S. Gateva

Experimental investigation of magneto-optical resonances on the potassium D2 line with λ=766.7 nm from the point of view of magnetometry applications is reported. The resonances are registered in a modified Hanle effect configuration based on counterpropagating pump and probe laser beams with orthogonal linear polarizations in a buffer gas cell with dimensions (diameter and length) of 8 mm. The amplitude, width, and contrast of the resonances registered in fluorescence and transmission are measured. The transformation of the bright magneto-optical resonances detected in fluorescence to dark ones by controlling the optical thickness of potassium vapor is analyzed. The influence of the laser intensity, buffer gas, and transverse magnetic field are considered. The experimental results show the system’s potential for magnetic field sensing and self-calibration.

AIP conference proceedings•Jan 1, 2024•0 citations

Nonlinear Magneto-optic Effects with Ultranarrow Widths

Dmitry Budker, Valeriy V. Yashchuk, Max S. Zolotorev

Several dispersionlike features in the magnetic field dependence of the nonlinear magneto-optic effect were observed in an experiment performed on rubidium atoms contained in a vapor cell with antirelaxation coating. The narrowest feature has effective resonance width $\ensuremath{\gamma}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}g\ensuremath{\mu}\ensuremath{\Delta}{B}_{z}\ensuremath{\approx}2\ensuremath{\pi}\ifmmode\times\else\texttimes\fi{}1.3\mathrm{Hz}$, where $\ensuremath{\Delta}{B}_{z}\ensuremath{\approx}2.8\ensuremath{\mu}\mathrm{G}$ is the peak-to-peak separation. The observed nontrivial dependence of the magneto-optic effect on transverse magnetic fields is discussed. The results of this work may be applied to low-field magnetometry, to parity and time reversal invariance violation experiments, etc.

Physical Review Letters•Dec 28, 1998•239 citations

Local Field Effect on Magneto-Optical Feshbach Resonance

Guangjiong Dong, He Yang, Fusheng Liu

•Jan 1, 2025•0 citations

Local field effect on Magneto-optical Feshbach Resonance

He Yang, Fusheng Liu, Guangjiong Dong

Optics Communications•Apr 13, 2025•0 citations
Experimental investigation of magneto-optical resonances on the potassium D2 line with λ=766.7 nm from the point of view of magnetometry applications is reported. The resonances are registered in a modified Hanle effect configuration based on counterpropagating pump and probe laser beams with orthogonal linear polarizations in a buffer gas cell with dimensions (diameter and length) of 8 mm. The amplitude, width, and contrast of the resonances registered in fluorescence and transmission are measured. The transformation of the bright magneto-optical resonances detected in fluorescence to dark ones by controlling the optical thickness of potassium vapor is analyzed. The influence of the laser intensity, buffer gas, and transverse magnetic field are considered. The experimental results show the system’s potential for magnetic field sensing and self-calibration.
Several dispersionlike features in the magnetic field dependence of the nonlinear magneto-optic effect were observed in an experiment performed on rubidium atoms contained in a vapor cell with antirelaxation coating. The narrowest feature has effective resonance width $\ensuremath{\gamma}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}g\ensuremath{\mu}\ensuremath{\Delta}{B}_{z}\ensuremath{\approx}2\ensuremath{\pi}\ifmmode\times\else\texttimes\fi{}1.3\mathrm{Hz}$, where $\ensuremath{\Delta}{B}_{z}\ensuremath{\approx}2.8\ensuremath{\mu}\mathrm{G}$ is the peak-to-peak separation. The observed nontrivial dependence of the magneto-optic effect on transverse magnetic fields is discussed. The results of this work may be applied to low-field magnetometry, to parity and time reversal invariance violation experiments, etc.