Physica C Superconductivity

Improvement of the quality factor of a microstrip resonator by the selective mode damping technique

А. Л. Карузский, Alexander N. Lykov, Vladimir N. Murzin, N. A. Volchkov

Published Apr 13, 2004• 0 citations
Publisher
DOI
10.1016/j.physc.2004.03.075

Related papers

Improvement in Superconducting Resonator Quality Factor Through Surface Passivation

Cassidy Berk, Archan Banerjee, Ahmed Hajr +5 more

Bulletin of the American Physical Society•Mar 19, 2021•1 citation

Increased quality factor in superconducting microstrip resonators by selective removal of the gold contact layer

Ralf Schneider, A. G. Zaitsev, Jochen Geerk +3 more

We present measurements of the unloaded quality factor of superconducting microstrip resonators at 77 K and 3.86 GHz. The resonators were made of 0.3 μm thick YBa 2 Cu 3 O 7 films with a transition temperature of 90 K on both sides of ceria-buffered 3 inch sapphire wafers. In particular, we investigated the effect of a 0.3 μm thick gold contact layer on the resonator performance. It was found that the gold layer decreases the quality factor by a factor of almost 5. This result is due to an additional microwave loss in the gold film which can be quantitatively described by the impedance transformation rules for transmission lines. On the basis of the quantitative analysis, we suggest a selective removal of the contact layer by appropriate patterning in order to eliminate the extra loss without deterioration of the low-ohmic galvanic contact to the microwave housing. The experimental results demonstrate the usefulness of the proposed method. Their comparison with the calculated surface current density in the ground plane shows that the contact layer has to be in an area where the current is zero. Furthermore, the results reveal that the surface current density distribution in the ground plane and microstrip depends on the microwave power.

Superconductor Science and Technology•Jan 9, 2002•3 citations

Intermodulation Distortion in Microstrip Superconducting Resonator: Measurements and Simulation

Orest G. Vendik, T. B. Samoǐlova, Разумов Сергей Владимирович +2 more

Springer eBooks•Jan 1, 1997•2 citations

EIGENMODES OF A RESONATOR WITH ACTIVE MEDIUM

А. В. Белинский, A. S. Chirkin

•Jan 1, 1989•0 citations

Measurement of loss in superconducting microstrip at millimeter-wave frequencies

Jiansong Gao, Anastasios Vayonakis, Omid Noroozian +6 more

We have developed a new technique for accurate measurement of the loss of superconducting microstrips at mm‐wave frequencies. In this technique, we optically couple power to slot antenna, which is connected to one port of a hybrid coupler. One of the output ports of the hybrid delivers power to a series of mm‐wave microstrip resonators which are capacitively coupled to a feedline followed by an MKID (microwave kinetic inductance detector) that measures the transmitted power. Two other MKIDs are connected to the remaining ports of the hybrid to measure the total incident optical power and the power reflected from the mm‐wave resonators, allowing |S21|2 and |S11|2 to be accurately determined and resonance frequency fr and quality factor Q to be retrieved. We have fabricated such a Nb/SiO2/Nb microstrip loss test device which contains several mm‐ wave resonators with fr∼100 GHz and measured it at 30 mK. All the resonators have shown internal quality factor Qi∼500–2000, suggesting a loss tangent of ∼5×10−4−2×10−3 for the SiO2 in use. For comparison, we have also fabricated a 5 GHz microstrip resonator on the same chip and measured it with a network analyzer. The loss tangent at 5 GHz derived from fitting the f0 and Q data to the two‐level system (TLS) model is 6×10−4, about the same as from the mm‐wave measurement. This suggests that the loss at both microwave and mm‐wave frequencies is probably dominated by the TLS in SiO2. Our results are of direct interest to mm/submm direct detection applications which use microstrip transmission lines (such as antenna‐coupled MKIDs and transition‐edge sensors), and other applications (such as on‐chip filters). Our measurement technique is applicable up to approximately 1 THz and can be used to investigate a range of dielectrics.

AIP conference proceedings•Jan 1, 2009•13 citations

MODES OF RESONATORS WITH MODULATED REFLECTIVITY MIRRORS

S. De Silvestri, P. Laporta, Vittorio C. Magni +1 more

•Jul 18, 1988•0 citations
We present measurements of the unloaded quality factor of superconducting microstrip resonators at 77 K and 3.86 GHz. The resonators were made of 0.3 μm thick YBa 2 Cu 3 O 7 films with a transition temperature of 90 K on both sides of ceria-buffered 3 inch sapphire wafers. In particular, we investigated the effect of a 0.3 μm thick gold contact layer on the resonator performance. It was found that the gold layer decreases the quality factor by a factor of almost 5. This result is due to an additional microwave loss in the gold film which can be quantitatively described by the impedance transformation rules for transmission lines. On the basis of the quantitative analysis, we suggest a selective removal of the contact layer by appropriate patterning in order to eliminate the extra loss without deterioration of the low-ohmic galvanic contact to the microwave housing. The experimental results demonstrate the usefulness of the proposed method. Their comparison with the calculated surface current density in the ground plane shows that the contact layer has to be in an area where the current is zero. Furthermore, the results reveal that the surface current density distribution in the ground plane and microstrip depends on the microwave power.
We have developed a new technique for accurate measurement of the loss of superconducting microstrips at mm‐wave frequencies. In this technique, we optically couple power to slot antenna, which is connected to one port of a hybrid coupler. One of the output ports of the hybrid delivers power to a series of mm‐wave microstrip resonators which are capacitively coupled to a feedline followed by an MKID (microwave kinetic inductance detector) that measures the transmitted power. Two other MKIDs are connected to the remaining ports of the hybrid to measure the total incident optical power and the power reflected from the mm‐wave resonators, allowing |S21|2 and |S11|2 to be accurately determined and resonance frequency fr and quality factor Q to be retrieved. We have fabricated such a Nb/SiO2/Nb microstrip loss test device which contains several mm‐ wave resonators with fr∼100 GHz and measured it at 30 mK. All the resonators have shown internal quality factor Qi∼500–2000, suggesting a loss tangent of ∼5×10−4−2×10−3 for the SiO2 in use. For comparison, we have also fabricated a 5 GHz microstrip resonator on the same chip and measured it with a network analyzer. The loss tangent at 5 GHz derived from fitting the f0 and Q data to the two‐level system (TLS) model is 6×10−4, about the same as from the mm‐wave measurement. This suggests that the loss at both microwave and mm‐wave frequencies is probably dominated by the TLS in SiO2. Our results are of direct interest to mm/submm direct detection applications which use microstrip transmission lines (such as antenna‐coupled MKIDs and transition‐edge sensors), and other applications (such as on‐chip filters). Our measurement technique is applicable up to approximately 1 THz and can be used to investigate a range of dielectrics.