Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Radiometric applications of correlated photon metrology

Jessica Y. Cheung, Christopher J. Chunnilall, Jian Wang

Published Oct 19, 2004• 5 citations
Publisher

Abstract

Many of the schemes utilizing photon states under investigation for Quantum Information Processing (QIP) technology involve active and passive optical components. In order to be able to establish fidelity levels for these schemes, the performance of these optical components and their coupling efficiencies require careful and accurate characterization. Correlated photons, the basis of entangled photon states, offer a direct means of measuring detector quantum efficiency and source radiance in the photon counting regime. Detector and source calibration by correlated photon techniques therefore address some of the key factors critical to QIP technology and the developing techniques of correlated/entangled photon metrology. Work is being undertaken at NPL to establish the accuracy limitations of the correlated photon technique for detector and source calibration. This paper will report on investigations concerning the characterization of silicon avalanche photodiode detectors using the correlated photon technique.

DOI
10.1117/12.561294

Related papers

Correlated photon metrology of detectors and sources

Jessica Y. Cheung, M. P. Vaughan, John R. Mountford +1 more

Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore address some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 3, 2004•7 citations

Correlated photon metrology of detectors and sources.

Jessica Y. Cheung, M. P. Vaughan, John R. Mountford +1 more

Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore addresses some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 1, 2004•3 citations

Quantum-efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero +1 more

We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.

Journal of the Optical Society of America B•Oct 1, 1999•15 citations

Quantum Radiometric Calibration

Leif Albers, Jan-Malte Michaelsen, Roman Schnabel

Optical quantum computing, as well as sensing technology based on quantum correlations are in preparation. These require photodiodes with close to perfect quantum efficiency for the detection of about 10^16 to 10^18 photons per second. Already the radiometric calibration is a challenge. Here, we provide the proof of concept of the quantum radiometric calibration (QRC) method, which is based on Heisenberg's uncertainty principle, derive the formula for its precision, and exclude the potential sources of systematic error. As an example, we calibrate a pair of the most efficient commercial photodiode at 1550 nm to the previously unknown system detection efficiency of (97.20 +/- 0.37)% using 10-dB-squeezed vacuum states. This value is unexpectedly low, too low for planned gravitational wave detectors and for continuous-variable optical quantum computing. With further improved precision, our work opens up the second true end-user application of the advantage provided by quantum correlations.

quant-pharXiv:2512.14947•Dec 18, 2025•0 citations

Intercomparison of a correlated-photon-based method to measure detector quantum efficiency

Alan L. Migdall, Stefania Castelletto, Ivo Pietro Degiovanni +1 more

We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory comparison to demonstrate the inherent absoluteness of the photon correlation technique by showing its independence from the particular experimental setup. We find that detector nonuniformity limited this comparison rather than uncertainty inherent in the method itself. The ultimate goal of these investigations is development of a robust measurement protocol that allows the uncertainties of individual measurements to be determined experimentally and verified operationally. Furthermore, to demonstrate the generality of the procedure, the IEN measurement setup was also used to calibrate a fiber-coupled avalanche photodiode module. Uncertainties are evaluated for the detector both with and without fiber coupling and differences are discussed. The current IEN setup using a thinner and higher transmittance nonlinear crystal for the generation of correlated photons shows a significant improvement in overall accuracy with respect to previously reported results from IEN [Metrologia 32, 501-503 (1996)].

Applied Optics•May 20, 2002•33 citations

Quantum efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero +1 more

We report the first results concerning quantum efficiency measurement of photodetectors with the technique of correlated photons generated by parametric down conversion in a nonlinear crystal. Measurements have been performed on photomultipliers in photon counting regime and will be extended to avalanche photodiodes working as single photon detectors.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•1 citation
Many of the schemes utilizing photon states under investigation for Quantum Information Processing (QIP) technology involve active and passive optical components. In order to be able to establish fidelity levels for these schemes, the performance of these optical components and their coupling efficiencies require careful and accurate characterization. Correlated photons, the basis of entangled photon states, offer a direct means of measuring detector quantum efficiency and source radiance in the photon counting regime. Detector and source calibration by correlated photon techniques therefore address some of the key factors critical to QIP technology and the developing techniques of correlated/entangled photon metrology. Work is being undertaken at NPL to establish the accuracy limitations of the correlated photon technique for detector and source calibration. This paper will report on investigations concerning the characterization of silicon avalanche photodiode detectors using the correlated photon technique.
Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore address some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.
Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore addresses some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.
We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.
Optical quantum computing, as well as sensing technology based on quantum correlations are in preparation. These require photodiodes with close to perfect quantum efficiency for the detection of about 10^16 to 10^18 photons per second. Already the radiometric calibration is a challenge. Here, we provide the proof of concept of the quantum radiometric calibration (QRC) method, which is based on Heisenberg's uncertainty principle, derive the formula for its precision, and exclude the potential sources of systematic error. As an example, we calibrate a pair of the most efficient commercial photodiode at 1550 nm to the previously unknown system detection efficiency of (97.20 +/- 0.37)% using 10-dB-squeezed vacuum states. This value is unexpectedly low, too low for planned gravitational wave detectors and for continuous-variable optical quantum computing. With further improved precision, our work opens up the second true end-user application of the advantage provided by quantum correlations.
We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory comparison to demonstrate the inherent absoluteness of the photon correlation technique by showing its independence from the particular experimental setup. We find that detector nonuniformity limited this comparison rather than uncertainty inherent in the method itself. The ultimate goal of these investigations is development of a robust measurement protocol that allows the uncertainties of individual measurements to be determined experimentally and verified operationally. Furthermore, to demonstrate the generality of the procedure, the IEN measurement setup was also used to calibrate a fiber-coupled avalanche photodiode module. Uncertainties are evaluated for the detector both with and without fiber coupling and differences are discussed. The current IEN setup using a thinner and higher transmittance nonlinear crystal for the generation of correlated photons shows a significant improvement in overall accuracy with respect to previously reported results from IEN [Metrologia 32, 501-503 (1996)].