Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Performance of a GaAlAs laser diode stabilized on a hyperfine component of two-photon transitions in rubidium at 778 nm

Raymond Felder, Driss Touahri, O. Acef, Laurent Hilico, J.‐J. Zondy, André Clairon, B. de Beauvoir, F. Biraben, Lucile Julien, F. Nez, Yves P. Millerioux

Published Apr 26, 1995• 9 citations
Publisher

Abstract

The absolute frequency measurement of each hyperfine component of the 5S3/2 and 5S5/2 levels in rubidium was done at ENS more than one year ago using Ti-Sa lasers. We built two devices based on diode lasers to study some metrological properties. We measure the frequency differences between hyperfine components of the 5S5/2 level and we calculate the corresponding hyperfine constants. We also measure the frequency interval between the 5S3/2 and 5S5/2 levels using a Schottky diode. The measured stability in terms of Allan variance is 3*10-13t-1/2 up to 2000 s. The light shift is investigated and the difference between our two systems is 1.7 kHz. The repeatability of one system is better than 10-12 and will allow the absolute frequency measurement at this level via the LPTF frequency synthesis chain.

DOI
10.1117/12.208244

Related papers

A potential new frequency/wavelength standard at 778 nm: Doppler free two-photon transitions in rubidium

Yves P. Millerioux, R. Felder, Driss Touahri +7 more

We have stabilized two laser diodes on the hyperfine components of the 5D/sub 3/2/ and 5D/sub 5/2/ two-photon transitions in natural rubidium (v=385 THz). We have carefully investigated the metrological features of these devices. So far we obtain a frequency stability in terms of the Allan variance of 3.10/sup -13/./spl tau//sup - 1/2 / up to 2000 s and a frequency repeatability of the order of 10/sup -12/. The frequency difference between the two devices is 1.7 kHz under identical operating conditions.>

Conference on Precision Electromagnetic Measurements•Dec 17, 2002•3 citations

Compact frequency standard at 1556 nm based on the two-photon transition in rubidium at 778 nm

Michel Poulin, Christine Latrasse, Driss Touahri +2 more

This is a progress report on the realization of a compact and transportable frequency standard at 1556 nm based on a two-photon transition in rubidium at 778 nm. These hyperfine transitions present great metrological interest. They have a narrow theoretical linewidth of 150 kHz when observed with a 1556 nm laser, and their absolute frequency is known with an uncertainty of 5.2 X 10-12. In this experiment, we use a high power 1556 nm DFB laser and reduce its linewidth to the 10 kHz level using optical feedback from a confocal cavity. We generate its second harmonic in a periodically poled LiNbO3 crystal and use this signal to injection-lock a Fabry-Perot laser emitting 42 mW at 778 nm. The slave laser is used to observe the Doppler-free two- photon transitions: two counter-propagating beams excite rubidium atoms which emit a blue fluorescence on resonance. This 420 nm light is detected on the side of the Rb cell with a photomultiplier. Such an optical frequency standard at 1556 nm, standing in the multiwavelength telecommunications systems window, becomes an attractive source for absolute frequency calibration of WDM components, optical spectrum analyzers and wavemeters.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 1998•0 citations

Progress in the development of an optical frequency standard at 192.6 THz based on a two-photon transition of rubidium atoms at Laval University

Christine Latrasse, M. Poulin, Driss Touahri +2 more

We have developed frequency standards at 192.6 THz (1556.2 nm) based on the two-photon transitions in rubidium at 385.2 THz (778.1 nm). These standards use a high power DFB laser at 1556.2 nm and second harmonic generation (SHG) in a periodically poled lithium niobate (PPLN) crystal. The linewidth of the DFB is reduced to the kHz level using optical feedback from a confocal cavity. The SH light is used to injection-lock a 778.1 nm laser diode which allows to observe and lock the 1556.2 nm laser to the (5S/sub 1/2/,F/sub g/=2-5D/sub 5/2/,F/sub e/=4) two-photon transition /sup 87/Rb. Allan variance measurements between identical standards show a beat stability 2.5/spl times/10/sup -13///spl tau//sup 1/2/ for observation times between 100 ms and 10 s and a level of 5.8/spl times/10/sup -14/ for 100 s is obtained. These standards have been moved recently to the National Research Council, Ottawa, Canada in order to measure their absolute frequency.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•1 citation

Accessing the $\rm 5S_{1/2} \rightarrow 5D_{5/2}$ two-photon transition in Rb using a diode laser system

Ketan D. Rathod, Vasant Natarajan A

We report observation of the $\rm 5S_{1/2} \rightarrow 5D_{5/2}$ two-photon transition in Rb vapor at 778 nm, using an external cavity diode laser system and a heated vapor cell. The spectra in the two isotopes show well-resolved hyperfine transitions. The peaks are Doppler free, and have a Lorentzian lineshape with a typical linewidth of 2.2 MHz. This linewidth is larger than the natural linewidth of 300 kHz, but is still 5--10 times smaller than the linewidth for single-photon transitions in the D$_2$ line. Since the absolute frequency of this transition is measured with 8 kHz precision, it can form a better secondary reference in the optical regime compared to the D$_2$ line.

arXiv:1511.05100•Nov 13, 2015•1 citation

Metrological features of the rubidium two-photon standards of the BNM-LPTF and Kastler Brossel Laboratories

Laurent Hilico, R. Felder, Driss Touahri +3 more

We have built three optical frequency standards based on the two-photon transition of rubidium at 778 nm, and analysed their performance over a period of more than three years. We discuss some systematic effects that could lead to the reproducibility we observe, and point out the possible improvements of the devices. We also examine the short and long term stabilities of the systems, and show that we have reached their ultimate performances.

The European Physical Journal Applied Physics•Nov 1, 1998•44 citations

Characterization of Frequency-Doubled 1.5-$\mu$ m Lasers for High-Performance Rb Clocks

Nil Almat, William Moreno, Matthieu Pellaton +3 more

We report on the characterization of two fiber-coupled 1.5-μm diode lasers, frequency-doubled and stabilized to Rubidium (Rb) atomic resonances at 780 nm. Such laser systems are of interest in view of their implementation in Rb vapor-cell atomic clocks, as an alternative to lasers emitting directly at 780 nm. The spectral properties and the instabilities of the frequency-doubled lasers are evaluated against a state-of-the-art compact Rb-stabilized laser system based on a distributed-feedback laser diode emitting at 780 nm. All three lasers are frequency stabilized using essentially identical Doppler-free spectroscopy schemes. The long-term optical power fluctuations at 780 nm are measured, simultaneously with the frequency instability measurements done by three beat notes established between the three lasers. One of the frequency-doubled laser systems shows at 780 nm excellent spectral properties. Its relative intensity noise-12Hz-1is one order of magnitude lower than the reference 780-nm laser, and the frequency noise6Hz2/Hz is limited by the laser current source. Its optical frequency instability is-12at τ = 1 s, limited by the reference laser, and better than 1 × 10-11at all timescales up to one day. We also evaluate the impact of the laser spectral properties and instabilities on the Rb atomic clock performance, in particular taking into account the light-shift effect. Optical power instabilities on long-term timescales, largely originating from the frequency-doubling stage, are identified as a limitation in view of high-performance Rb atomic clocks.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jan 15, 2018•9 citations
The absolute frequency measurement of each hyperfine component of the 5S3/2 and 5S5/2 levels in rubidium was done at ENS more than one year ago using Ti-Sa lasers. We built two devices based on diode lasers to study some metrological properties. We measure the frequency differences between hyperfine components of the 5S5/2 level and we calculate the corresponding hyperfine constants. We also measure the frequency interval between the 5S3/2 and 5S5/2 levels using a Schottky diode. The measured stability in terms of Allan variance is 3*10-13t-1/2 up to 2000 s. The light shift is investigated and the difference between our two systems is 1.7 kHz. The repeatability of one system is better than 10-12 and will allow the absolute frequency measurement at this level via the LPTF frequency synthesis chain.
We have stabilized two laser diodes on the hyperfine components of the 5D/sub 3/2/ and 5D/sub 5/2/ two-photon transitions in natural rubidium (v=385 THz). We have carefully investigated the metrological features of these devices. So far we obtain a frequency stability in terms of the Allan variance of 3.10/sup -13/./spl tau//sup - 1/2 / up to 2000 s and a frequency repeatability of the order of 10/sup -12/. The frequency difference between the two devices is 1.7 kHz under identical operating conditions.>
This is a progress report on the realization of a compact and transportable frequency standard at 1556 nm based on a two-photon transition in rubidium at 778 nm. These hyperfine transitions present great metrological interest. They have a narrow theoretical linewidth of 150 kHz when observed with a 1556 nm laser, and their absolute frequency is known with an uncertainty of 5.2 X 10-12. In this experiment, we use a high power 1556 nm DFB laser and reduce its linewidth to the 10 kHz level using optical feedback from a confocal cavity. We generate its second harmonic in a periodically poled LiNbO3 crystal and use this signal to injection-lock a Fabry-Perot laser emitting 42 mW at 778 nm. The slave laser is used to observe the Doppler-free two- photon transitions: two counter-propagating beams excite rubidium atoms which emit a blue fluorescence on resonance. This 420 nm light is detected on the side of the Rb cell with a photomultiplier. Such an optical frequency standard at 1556 nm, standing in the multiwavelength telecommunications systems window, becomes an attractive source for absolute frequency calibration of WDM components, optical spectrum analyzers and wavemeters.
We have developed frequency standards at 192.6 THz (1556.2 nm) based on the two-photon transitions in rubidium at 385.2 THz (778.1 nm). These standards use a high power DFB laser at 1556.2 nm and second harmonic generation (SHG) in a periodically poled lithium niobate (PPLN) crystal. The linewidth of the DFB is reduced to the kHz level using optical feedback from a confocal cavity. The SH light is used to injection-lock a 778.1 nm laser diode which allows to observe and lock the 1556.2 nm laser to the (5S/sub 1/2/,F/sub g/=2-5D/sub 5/2/,F/sub e/=4) two-photon transition /sup 87/Rb. Allan variance measurements between identical standards show a beat stability 2.5/spl times/10/sup -13///spl tau//sup 1/2/ for observation times between 100 ms and 10 s and a level of 5.8/spl times/10/sup -14/ for 100 s is obtained. These standards have been moved recently to the National Research Council, Ottawa, Canada in order to measure their absolute frequency.
Accessing the 5S1/2→5D5/2\rm 5S_{1/2} \rightarrow 5D_{5/2}5S1/2​→5D5/2​ two-photon transition in Rb using a diode laser system
We report observation of the 5S1/2→5D5/2\rm 5S_{1/2} \rightarrow 5D_{5/2}5S1/2​→5D5/2​ two-photon transition in Rb vapor at 778 nm, using an external cavity diode laser system and a heated vapor cell. The spectra in the two isotopes show well-resolved hyperfine transitions. The peaks are Doppler free, and have a Lorentzian lineshape with a typical linewidth of 2.2 MHz. This linewidth is larger than the natural linewidth of 300 kHz, but is still 5--10 times smaller than the linewidth for single-photon transitions in the D2_22​ line. Since the absolute frequency of this transition is measured with 8 kHz precision, it can form a better secondary reference in the optical regime compared to the D2_22​ line.
Characterization of Frequency-Doubled 1.5-μ\muμ m Lasers for High-Performance Rb Clocks
We report on the characterization of two fiber-coupled 1.5-μm diode lasers, frequency-doubled and stabilized to Rubidium (Rb) atomic resonances at 780 nm. Such laser systems are of interest in view of their implementation in Rb vapor-cell atomic clocks, as an alternative to lasers emitting directly at 780 nm. The spectral properties and the instabilities of the frequency-doubled lasers are evaluated against a state-of-the-art compact Rb-stabilized laser system based on a distributed-feedback laser diode emitting at 780 nm. All three lasers are frequency stabilized using essentially identical Doppler-free spectroscopy schemes. The long-term optical power fluctuations at 780 nm are measured, simultaneously with the frequency instability measurements done by three beat notes established between the three lasers. One of the frequency-doubled laser systems shows at 780 nm excellent spectral properties. Its relative intensity noise-12Hz-1is one order of magnitude lower than the reference 780-nm laser, and the frequency noise6Hz2/Hz is limited by the laser current source. Its optical frequency instability is-12at τ = 1 s, limited by the reference laser, and better than 1 × 10-11at all timescales up to one day. We also evaluate the impact of the laser spectral properties and instabilities on the Rb atomic clock performance, in particular taking into account the light-shift effect. Optical power instabilities on long-term timescales, largely originating from the frequency-doubling stage, are identified as a limitation in view of high-performance Rb atomic clocks.