Applied Physics Letters

Temperature measurement of cold atoms using single-atom transits and Monte Carlo simulation in a strongly coupled atom-cavity system

Wenfang Li, Jinjin Du, Ruijuan Wen, Pengfei Yang, Gang Li, J.-Q. Liang, Tiancai Zhang

Published Mar 17, 2014• 7 citations
Publisher

Abstract

We investigate the transmission of single-atom transits based on a strongly coupled cavity quantum electrodynamics system. By superposing the transit transmissions of a considerable number of atoms, we obtain the absorption spectra of the cavity induced by single atoms and obtain the temperature of the cold atom. The number of atoms passing through the microcavity for each release is also counted, and this number changes exponentially along with the atom temperature. Monte Carlo simulations agree closely with the experimental results, and the initial temperature of the cold atom is determined. Compared with the conventional time-of-flight (TOF) method, this approach avoids some uncertainties in the standard TOF and sheds new light on determining temperature of cold atoms by counting atoms individually in a confined space.

DOI
10.1063/1.4869031

Related papers

Temperature determination of cold atoms based on single-atom countings

Pengfei Zhang, Yanqiang Guo, Zhuoheng Li +6 more

Based on the real sense of the time-of-flight , we demonstrate an alternative method of measuring the temperature of cold atoms in magneto-optical traps (MOTs) using a high-finesse optical microcavity, which acts as a pointlike single-atom counter. A cloud of atoms trapped in magneto-optical traps is positioned about 5 mm above the cavity, and the atoms fall freely down through the cavity. The temperature of the cold atoms in the MOT is determined by counting the exact arrival times of the single atoms. A theoretical model based on a ballistic expansion of a cloud of trapped atoms falling in the earth’s gravitational field is used to fit the probability distribution of atom arrivals, and the fittings agree very well with the experimental results. This method could be used for systems with little room, where an extra probe beam is hard to involve, or with fewer atoms initially.

Journal of the Optical Society of America B•Mar 9, 2011•13 citations

Single-atom transfer in a strongly coupled cavity quantum electrodynamics: experiment and Monte Carlo simulation

LI Wen-fang, Jinjin Du, Ruijuan Wen +3 more

The process of single-atom transfer in strongly coupled cavity quantum electrodynamics (QED) with free falling atoms is investigated by experiment and Monte Carlo simulation. We conduct the simulation of the whole physical process and give the corresponding experimental results. In experiment, a high finesse optical cavity is used for real-time detection of the single-atom transits from which the interaction information between single atoms and cavity can be extracted, including the transmission spectra of the cavity strongly coupled to single atoms, the interaction duration of the single atoms in the mode, the probability distribution of atom arrival time and the atomic kinetic energy distribution when arriving at the mode. All these can be completely derived from the transmission spectra of the different initial status. An intracavity far-off resonance trap (FORT) has been established and the single-atom trapping time inside the cavity is about 5 ms which is about 30 times longer than that without FORT. This study gives the detailed analysis of the whole procedure of free-falling atom transfer in cavity QED system and is helpful for optimizing the experimental parameters and design.

Acta Physica Sinica•Jan 1, 2014•4 citations

Time-of-flight measurement of the temperature of cold atoms for short trap-probe beam distances

Tomasz Brzozowski, Maria Maczynska, M. Zawada +2 more

We analyse the time-of-flight method of measuring the temperature of cold trapped atoms in the specific case of short distances of the probe beam from the trap centre and finite atomic cloud size. We theoretically examine the influence of the probe beam shape and its distance from the initial position of the cloud on the temperature evaluation. These results are then verified with a three-dimensional Monte Carlo simulation and applied to our experimental data to show that the proposed procedure allows accurate and reliable determination of the temperature.

Journal of Optics B Quantum and Semiclassical Optics•Jan 14, 2002•88 citations

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

Temperature measurement of laser-cooled atoms using vacuum Rabi splitting

Tridib Ray, Arijit Sharma, S. Jyothi +1 more

We laser cool rubidium atoms to form a magneto-optical trap, within a Fabry-Perot cavity, and demonstrate strong coupling of the cold atoms to the cavity. The coupling strength is measured using the vacuum Rabi frequency splitting (VRS) of transmitted, cavity-coupled light on atomic resonance. The VRS is measured for two- and three-level atomic systems and the atom-cavity-coupling strength for each system is determined. By allowing the laser-cooled atoms to expand for different times and measuring the corresponding VRS, we determine the number of atoms overlapped with the cavity mode as a function of time. This time-of-flight of atoms from the cavity permits the measurement of the temperature of the laser-cooled atoms. Finally, the need for this technique and its utility is discussed.

Physical Review A•Mar 26, 2013•19 citations

Cavity cooling and spectroscopy of a bound atom-cavity system

Peter Maunz

Cooling is indispensable for trapping and observing single free atoms.In atomic physics, this can be achieved efficiently by laser cooling.Conventional methods to laser cool atoms are based on repeated optical pumping cycles followed by spontaneous emission of a photon from the atom.Such pumping schemes can only be applied to certain atomic species, which have a closed optical transition.Drawbacks caused by photons spontaneously emitted from the atom can be avoided in the strongly coupled atom-cavity system in which energy and entropy can be removed by photons lost from the cavity.This thesis reports on the first observation of this cooling mechanism which does not rely on spontaneous emission.In the experiment, a single atom is captured in an intracavity dipole trap.Illuminating the system with a weak, slightly blue-detuned light beam extends the storage time of the atom in the trap.The observed cooling force is at least five times larger than the force achieved by free-space cooling methods at comparable excitation of a two-level atom.Utilising cavity cooling, single atoms are prepared strongly-coupled to the mode of a high-finesse cavity.This allows to observe two well-resolved normal-mode peaks in both the cavity transmission as well as in the trap lifetime.The experiment is in agreement with a Monte Carlo simulation, demonstrating the localisation of the atom to within a tenth of a wavelength.The ability to individually excite the normal modes opens new possibilities to use this system for applications in quantum information science, including the realisation of quantum-logic gates.In the future cavity cooling might be applied to systems which cannot be cooled by conventional methods as for instance molecules or an atom carrying a quantum bit.

•Mar 1, 2005•3 citations
We investigate the transmission of single-atom transits based on a strongly coupled cavity quantum electrodynamics system. By superposing the transit transmissions of a considerable number of atoms, we obtain the absorption spectra of the cavity induced by single atoms and obtain the temperature of the cold atom. The number of atoms passing through the microcavity for each release is also counted, and this number changes exponentially along with the atom temperature. Monte Carlo simulations agree closely with the experimental results, and the initial temperature of the cold atom is determined. Compared with the conventional time-of-flight (TOF) method, this approach avoids some uncertainties in the standard TOF and sheds new light on determining temperature of cold atoms by counting atoms individually in a confined space.
Based on the real sense of the time-of-flight , we demonstrate an alternative method of measuring the temperature of cold atoms in magneto-optical traps (MOTs) using a high-finesse optical microcavity, which acts as a pointlike single-atom counter. A cloud of atoms trapped in magneto-optical traps is positioned about 5 mm above the cavity, and the atoms fall freely down through the cavity. The temperature of the cold atoms in the MOT is determined by counting the exact arrival times of the single atoms. A theoretical model based on a ballistic expansion of a cloud of trapped atoms falling in the earth’s gravitational field is used to fit the probability distribution of atom arrivals, and the fittings agree very well with the experimental results. This method could be used for systems with little room, where an extra probe beam is hard to involve, or with fewer atoms initially.
The process of single-atom transfer in strongly coupled cavity quantum electrodynamics (QED) with free falling atoms is investigated by experiment and Monte Carlo simulation. We conduct the simulation of the whole physical process and give the corresponding experimental results. In experiment, a high finesse optical cavity is used for real-time detection of the single-atom transits from which the interaction information between single atoms and cavity can be extracted, including the transmission spectra of the cavity strongly coupled to single atoms, the interaction duration of the single atoms in the mode, the probability distribution of atom arrival time and the atomic kinetic energy distribution when arriving at the mode. All these can be completely derived from the transmission spectra of the different initial status. An intracavity far-off resonance trap (FORT) has been established and the single-atom trapping time inside the cavity is about 5 ms which is about 30 times longer than that without FORT. This study gives the detailed analysis of the whole procedure of free-falling atom transfer in cavity QED system and is helpful for optimizing the experimental parameters and design.
We analyse the time-of-flight method of measuring the temperature of cold trapped atoms in the specific case of short distances of the probe beam from the trap centre and finite atomic cloud size. We theoretically examine the influence of the probe beam shape and its distance from the initial position of the cloud on the temperature evaluation. These results are then verified with a three-dimensional Monte Carlo simulation and applied to our experimental data to show that the proposed procedure allows accurate and reliable determination of the temperature.
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
We laser cool rubidium atoms to form a magneto-optical trap, within a Fabry-Perot cavity, and demonstrate strong coupling of the cold atoms to the cavity. The coupling strength is measured using the vacuum Rabi frequency splitting (VRS) of transmitted, cavity-coupled light on atomic resonance. The VRS is measured for two- and three-level atomic systems and the atom-cavity-coupling strength for each system is determined. By allowing the laser-cooled atoms to expand for different times and measuring the corresponding VRS, we determine the number of atoms overlapped with the cavity mode as a function of time. This time-of-flight of atoms from the cavity permits the measurement of the temperature of the laser-cooled atoms. Finally, the need for this technique and its utility is discussed.
Cooling is indispensable for trapping and observing single free atoms.In atomic physics, this can be achieved efficiently by laser cooling.Conventional methods to laser cool atoms are based on repeated optical pumping cycles followed by spontaneous emission of a photon from the atom.Such pumping schemes can only be applied to certain atomic species, which have a closed optical transition.Drawbacks caused by photons spontaneously emitted from the atom can be avoided in the strongly coupled atom-cavity system in which energy and entropy can be removed by photons lost from the cavity.This thesis reports on the first observation of this cooling mechanism which does not rely on spontaneous emission.In the experiment, a single atom is captured in an intracavity dipole trap.Illuminating the system with a weak, slightly blue-detuned light beam extends the storage time of the atom in the trap.The observed cooling force is at least five times larger than the force achieved by free-space cooling methods at comparable excitation of a two-level atom.Utilising cavity cooling, single atoms are prepared strongly-coupled to the mode of a high-finesse cavity.This allows to observe two well-resolved normal-mode peaks in both the cavity transmission as well as in the trap lifetime.The experiment is in agreement with a Monte Carlo simulation, demonstrating the localisation of the atom to within a tenth of a wavelength.The ability to individually excite the normal modes opens new possibilities to use this system for applications in quantum information science, including the realisation of quantum-logic gates.In the future cavity cooling might be applied to systems which cannot be cooled by conventional methods as for instance molecules or an atom carrying a quantum bit.