Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Temperature determination of cold atoms based on single-atom countings

Pengfei Zhang, Yanqiang Guo, Zhuoheng Li, Yuchi Zhang, Yanfeng Zhang, Jinjin Du, Gang Li, Junmin Wang, Tiancai Zhang

Published Mar 9, 2011• 13 citations
Publisher

Abstract

Based on the real sense of the time-of-flight , we demonstrate an alternative method of measuring the temperature of cold atoms in magneto-optical traps (MOTs) using a high-finesse optical microcavity, which acts as a pointlike single-atom counter. A cloud of atoms trapped in magneto-optical traps is positioned about 5 mm above the cavity, and the atoms fall freely down through the cavity. The temperature of the cold atoms in the MOT is determined by counting the exact arrival times of the single atoms. A theoretical model based on a ballistic expansion of a cloud of trapped atoms falling in the earth’s gravitational field is used to fit the probability distribution of atom arrivals, and the fittings agree very well with the experimental results. This method could be used for systems with little room, where an extra probe beam is hard to involve, or with fewer atoms initially.

DOI
10.1364/josab.28.000667

Related papers

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

Measurement of temperature of laser cooled atoms by one-dimensional expansion in a magneto-optical trap

Swarupananda Pradhan, B. N. Jagatap

We discuss a simple time of flight technique for measurement of temperature of a cold cloud in a magneto-optical trap (MOT). The technique is based on spatiotemporal fluorescence imaging of the cloud that is allowed to undergo one-dimensional expansion in the presence of the orthogonal two-dimensional configuration of laser beams by temporal modulation of a pair of counterpropagating trapping beams in the MOT. We show that, in the time scale 0< or =t<5 ms, the expansion of the cloud is ballistic and the temperature can be extracted from the time variation of the rms size of the cloud in the expansion direction. The reliability of the technique has been established by comparing the results with release and recapture method, and also by fitting them to the known temperature scaling law.

Review of Scientific Instruments•Jan 1, 2008•18 citations

Measurement of the number of cold atoms trapped in cesium magneto-optical trap via probe absorption

Yanhua Wang, Yang Hai-Jing, Tiancai Zhang +2 more

The number of cold atoms trapped in magneto-optical trap(MOT) can be derived from probe absorption signal. After the MOT is switched off, the cold cloud freely expands in gravitational field with an initial velocity distribution. So the measurement process can be described with the interaction model between the individual stationary two-level atom and single mode resonate laser. Absorption method can largely improved the measurement precision. In this paper we introduce the physical principle of measurement and demonstrate the whole experimental procedure in detail. The number of atoms trapped in our MOT, (8±0.3)×106 is measured in experiment. And the number of steady-state atoms and the lifetime of atom trapped in MOT was used to deduce the capture rate of MOT.

Acta Physica Sinica•Jan 1, 2006•3 citations

Fast nondestructive temperature measurement of two-electron atoms in a magneto-optical trap

Matteo Cristiani, T. Valenzuela, Hannes Gothe +1 more

We extend the technique originally proposed by [Honda et al., Phys. Rev. A 59, R934 (1999)] to measure the temperature of ytterbium and alkaline-earth-metal atoms confined in a magneto-optical trap (MOT). The method is based on the analysis of excitation spectra obtained by probing the ${}^{1}{\text{S}}_{0}\ensuremath{\rightarrow}{}^{3}{\text{P}}_{1}$ intercombination line. Thanks to a careful analysis and modeling of the effects caused by the MOT light on the probe transition we overcome the resolution and precision limits encountered in previous works. Ground-state light shift and Rabi broadening are measured and successfully compared with calculated values. This knowledge allows us to properly extract the Doppler contribution to the linewidth, thus obtaining a reliable measurement of the cloud temperature. We finally show how spectroscopy on free-falling atoms provides an alternative method to determine the sample temperature which resembles the standard time-of-flight technique.

arXiv:1002.2616•Physical Review A•Jun 17, 2010•12 citations

Time-of-flight measurement of the temperature of cold atoms for short trap-probe beam distances

Tomasz Brzozowski, Maria Maczynska, M. Zawada +2 more

We analyse the time-of-flight method of measuring the temperature of cold trapped atoms in the specific case of short distances of the probe beam from the trap centre and finite atomic cloud size. We theoretically examine the influence of the probe beam shape and its distance from the initial position of the cloud on the temperature evaluation. These results are then verified with a three-dimensional Monte Carlo simulation and applied to our experimental data to show that the proposed procedure allows accurate and reliable determination of the temperature.

Journal of Optics B Quantum and Semiclassical Optics•Jan 14, 2002•83 citations

A method of accurately determining temperature of cold atomic cloud in atomic fountain

Junru Shi, Xinliang Wang, Yong Guan +8 more

The Gaussian radius and temperature of cold atomic cloud are important parameters in describing the state of cold atoms. The precise measuring of these two parameters is of great significance for studying the cold atoms. In this paper, we propose a new method named knife-edge to measure the Gaussian radius and temperature of the cold atomic cloud. A near-resonant and supersaturated laser beam, whose size is controlled by a knife-edge aperture, is used to push away the cold atoms in the free falling process of cold atomic cloud. By detecting the intensity of fluorescence signal, the numbers of residual atoms under different-sized near-resonant beams can be obtained. According to the characteristic of cold atoms′ distribution, we construct a theoretical model to derive the Gaussian radius of cold atomic cloud from the recorded residual atom number and near-resonant beam size. Since the Gaussian radius and temperature of cold atomic cloud are associated with each other, we can finally obtain the temperature of cold atomic cloud through the recorded residual atom number and beam size. By using this method, we successfully measure the Gaussian radii of cold atomic cloud at the heights of 10 mm and 160 mm below the center of 3D-MOT (three dimensional magneto-optical trap) to be (1.54 ± 0.05) mm and (3.29 ± 0.08) mm, respectively. The corresponding temperature of cold atomic cloud is calculated to be (7.50 ± 0.49) μK, which is well consistent with the experimental result obtained by using the time-of-flight method under the same condition. This experiment is conducted on the platform of Cesium atomic fountain clock of National Time Service Center, China.

Acta Physica Sinica•Jan 1, 2019•3 citations
Based on the real sense of the time-of-flight , we demonstrate an alternative method of measuring the temperature of cold atoms in magneto-optical traps (MOTs) using a high-finesse optical microcavity, which acts as a pointlike single-atom counter. A cloud of atoms trapped in magneto-optical traps is positioned about 5 mm above the cavity, and the atoms fall freely down through the cavity. The temperature of the cold atoms in the MOT is determined by counting the exact arrival times of the single atoms. A theoretical model based on a ballistic expansion of a cloud of trapped atoms falling in the earth’s gravitational field is used to fit the probability distribution of atom arrivals, and the fittings agree very well with the experimental results. This method could be used for systems with little room, where an extra probe beam is hard to involve, or with fewer atoms initially.
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
We discuss a simple time of flight technique for measurement of temperature of a cold cloud in a magneto-optical trap (MOT). The technique is based on spatiotemporal fluorescence imaging of the cloud that is allowed to undergo one-dimensional expansion in the presence of the orthogonal two-dimensional configuration of laser beams by temporal modulation of a pair of counterpropagating trapping beams in the MOT. We show that, in the time scale 0< or =t<5 ms, the expansion of the cloud is ballistic and the temperature can be extracted from the time variation of the rms size of the cloud in the expansion direction. The reliability of the technique has been established by comparing the results with release and recapture method, and also by fitting them to the known temperature scaling law.
The number of cold atoms trapped in magneto-optical trap(MOT) can be derived from probe absorption signal. After the MOT is switched off, the cold cloud freely expands in gravitational field with an initial velocity distribution. So the measurement process can be described with the interaction model between the individual stationary two-level atom and single mode resonate laser. Absorption method can largely improved the measurement precision. In this paper we introduce the physical principle of measurement and demonstrate the whole experimental procedure in detail. The number of atoms trapped in our MOT, (8±0.3)×106 is measured in experiment. And the number of steady-state atoms and the lifetime of atom trapped in MOT was used to deduce the capture rate of MOT.
We extend the technique originally proposed by [Honda et al., Phys. Rev. A 59, R934 (1999)] to measure the temperature of ytterbium and alkaline-earth-metal atoms confined in a magneto-optical trap (MOT). The method is based on the analysis of excitation spectra obtained by probing the ${}^{1}{\text{S}}_{0}\ensuremath{\rightarrow}{}^{3}{\text{P}}_{1}$ intercombination line. Thanks to a careful analysis and modeling of the effects caused by the MOT light on the probe transition we overcome the resolution and precision limits encountered in previous works. Ground-state light shift and Rabi broadening are measured and successfully compared with calculated values. This knowledge allows us to properly extract the Doppler contribution to the linewidth, thus obtaining a reliable measurement of the cloud temperature. We finally show how spectroscopy on free-falling atoms provides an alternative method to determine the sample temperature which resembles the standard time-of-flight technique.
We analyse the time-of-flight method of measuring the temperature of cold trapped atoms in the specific case of short distances of the probe beam from the trap centre and finite atomic cloud size. We theoretically examine the influence of the probe beam shape and its distance from the initial position of the cloud on the temperature evaluation. These results are then verified with a three-dimensional Monte Carlo simulation and applied to our experimental data to show that the proposed procedure allows accurate and reliable determination of the temperature.
The Gaussian radius and temperature of cold atomic cloud are important parameters in describing the state of cold atoms. The precise measuring of these two parameters is of great significance for studying the cold atoms. In this paper, we propose a new method named knife-edge to measure the Gaussian radius and temperature of the cold atomic cloud. A near-resonant and supersaturated laser beam, whose size is controlled by a knife-edge aperture, is used to push away the cold atoms in the free falling process of cold atomic cloud. By detecting the intensity of fluorescence signal, the numbers of residual atoms under different-sized near-resonant beams can be obtained. According to the characteristic of cold atoms′ distribution, we construct a theoretical model to derive the Gaussian radius of cold atomic cloud from the recorded residual atom number and near-resonant beam size. Since the Gaussian radius and temperature of cold atomic cloud are associated with each other, we can finally obtain the temperature of cold atomic cloud through the recorded residual atom number and beam size. By using this method, we successfully measure the Gaussian radii of cold atomic cloud at the heights of 10 mm and 160 mm below the center of 3D-MOT (three dimensional magneto-optical trap) to be (1.54 ± 0.05) mm and (3.29 ± 0.08) mm, respectively. The corresponding temperature of cold atomic cloud is calculated to be (7.50 ± 0.49) μK, which is well consistent with the experimental result obtained by using the time-of-flight method under the same condition. This experiment is conducted on the platform of Cesium atomic fountain clock of National Time Service Center, China.