Here an experiment is proposed to demonstrate squeezed-state enhanced interferometry. An interferometer employing differenced detection, in which the photodetectors have less than a unit quantum efficiency, is analyzed. In order to avoid low-frequency noise, a readout signal at frequency 2νs is generated at the detector by injecting coherent light having two frequency components ν0 + νs and ν0 − νs into one input port of the interferometer. In order to realize a significant sensitivity enhancement, squeezed light fed into the other input port must be squeezed at frequencies ν0 ± νs and ν0 + 3νs.
Here an experiment is proposed to demonstrate squeezed-state enhanced interferometry. An interferometer employing differenced detection, in which the photodetectors have less than a unit quantum efficiency, is analyzed. In order to avoid low-frequency noise, a readout signal at frequency 2νs is generated at the detector by injecting coherent light having two frequency components ν0 + νs and ν0 − νs into one input port of the interferometer. In order to realize a significant sensitivity enhancement, squeezed light fed into the other input port must be squeezed at frequencies ν0 ± νs and ν0 + 3νs.
A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.
Since the first proposal by Caves1 that squeezed light could be used to enhance the sensitivity of a gravitational wave interferometric antenna, squeezed states have been demonstrated in the laboratory but not yet used in an actual measurement system. This paper describes a polarization interferometer experiment, operated with a squeezed light source, designed to improve the interferometer sensitivity beyond the standard quantum limit. The interferometer consists of two polarization beam splitters, whose axes are oriented 45° with respect to each other. Linearly polarized incident laser light is transmitted by the first polarizer and split by the second one, which also acts as the splitter for a balanced homodyne detector. A rotation of the polarization between the two polarizers can be detected with quantum-limited sensitivity (e.g., ±1 μrad). The squeezed light entering the other port of the interferometer is produced using a χ2 crystal (KTP) in an optical cavity, pumped by a frequency-doubled cw ring Nd:YAG laser. The interferometer sensitivity can thus be increased by a factor depending on the degree of squeezing achieved and on the detector quantum efficiency. Sensitivity increases by factors between 2 and 3 are predicted, and current performance is described.
Conventional heterodyne readout schemes are now under reconsideration due to the realization of techniques to evade its inherent 3 dB signal-to-noise penalty. The application of high-frequency, quadrature-entangled, two-mode squeezed states can further improve the readout sensitivity of audio-band signals. In this Letter, we experimentally demonstrate quantum-enhanced heterodyne readout of two spatially distinct interferometers with direct optical signal combination, circumventing the 3 dB heterodyne signal-to-noise penalty. Applying a high-frequency, quadrature-entangled, two-mode squeezed state, we show further signal-to-noise improvement of an injected audio band signal of 3.5 dB. This technique is applicable for quantum-limited high-precision experiments, with application to searches for quantum gravity, searches for dark matter, gravitational wave detection, and wavelength-multiplexed quantum communication.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.