Annual Meeting Optical Society of America

Application of squeezed-state light to high-precision interferometry

Carlton M. Caves

Published Jan 1, 1986• 1 citation
Publisher

Abstract

A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.

DOI
10.1364/oam.1986.tua5

Related papers

Quantum-mechanical noise in an interferometer

Carlton M. Caves

The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.

Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 15, 1981•3,202 citations

Reduction of quantum noise in optical interferometers using squeezed light

Michael Weyrauch, Volodymyr G. Voronov

We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise a squeezed vacuum state is injected into the usually unused input port. Here, we specifically investigate the so-called “dark port case,” when the beam splitter is oriented close to 90° to the incoming laser beam, such that nearly all photons go to one output port of the interferometer, and only a small fraction of photons is seen in the other port (“dark port”). For this case it had been suggested that signal amplification is possible without concurrent noise amplification [R. Barak and Y. Ben-Aryeh, J. Opt. Soc. Am. B 25 , 361 (2008)]. We show that by injection of a squeezed vacuum state into the second input port, counting noise is reduced for large values of the squeezing factor, however the signal is not amplified. Signal strength only depends on the intensity of the laser beam.

arXiv:1010.5062•Optics and Spectroscopy•Nov 1, 2011•2 citations

Quantum noise reduction using squeezed states inLIGO; Sensitivity improvement of a LIGO gravitational Waynedetector through squeezed state injection

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.

•Jan 1, 2013•0 citations

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations

Quantum noise reduction using squeezed states in LIGO

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics

•Jan 1, 2013•14 citations

Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light

L. Barsotti, S. Biscans, Timothy P. Bodiya +26 more

Nearly a century after Einstein first predicted the existence of gravitational waves, a global network of Earth-based gravitational wave observatories 1-4 is seeking to directly detect this faint radiation using precision laser interferometry. Photon shot noise, due to the quantum nature of light, imposes a fundamental limit on the attometre-level sensitivity of the kilometre-scale Michelson interferometers deployed for this task. Here, we inject squeezed states to improve the performance of one of the detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) beyond the quantum noise limit, most notably in the frequency region down to 150 Hz, critically important for several astrophysical sources, with no deterioration of performance observed at any frequency. With the injection of squeezed states, this LIGO detector demonstrated the best broadband sensitivity to gravitational waves ever achieved, with important implications for observing the gravitational-wave Universe with unprecedented sensitivity.

Other repository•Jul 1, 2013•0 citations
A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.
The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.
We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise a squeezed vacuum state is injected into the usually unused input port. Here, we specifically investigate the so-called “dark port case,” when the beam splitter is oriented close to 90° to the incoming laser beam, such that nearly all photons go to one output port of the interferometer, and only a small fraction of photons is seen in the other port (“dark port”). For this case it had been suggested that signal amplification is possible without concurrent noise amplification [R. Barak and Y. Ben-Aryeh, J. Opt. Soc. Am. B 25 , 361 (2008)]. We show that by injection of a squeezed vacuum state into the second input port, counting noise is reduced for large values of the squeezing factor, however the signal is not amplified. Signal strength only depends on the intensity of the laser beam.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics
Nearly a century after Einstein first predicted the existence of gravitational waves, a global network of Earth-based gravitational wave observatories 1-4 is seeking to directly detect this faint radiation using precision laser interferometry. Photon shot noise, due to the quantum nature of light, imposes a fundamental limit on the attometre-level sensitivity of the kilometre-scale Michelson interferometers deployed for this task. Here, we inject squeezed states to improve the performance of one of the detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) beyond the quantum noise limit, most notably in the frequency region down to 150 Hz, critically important for several astrophysical sources, with no deterioration of performance observed at any frequency. With the injection of squeezed states, this LIGO detector demonstrated the best broadband sensitivity to gravitational waves ever achieved, with important implications for observing the gravitational-wave Universe with unprecedented sensitivity.