Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

RESEARCH OF FREQUENCY STANDARDS IN SIOM — ATOMIC FREQUENCY STANDARDS BASED ON COHERENT STORAGE

B. YAN, He Cheng, Y. S., W. Z. ZHANG, L. LIU, Y. Z. WANG

Published May 1, 2009• 0 citations
Publisher

Abstract

In this paper we proposed a frequency standard based on pulsed coherent storage (PCS), the basic idea of the PCS scheme is combining the information storage technique with the optical pumping method. It shows that the Ramsey pattern is printed on the coherence of the atom states, then is detected in the form of the retrieval light. The proposed PCS frequency standards are free of light shifts, low Q requirement, high signal contrast and low noise background. The estimated frequency stability is 2 × 10 -14 in 1 second. Meanwhile we report the progress in laser cooling of atoms in an integrating sphere, some experimental results are given. This cooling method provides a robust source which is suitable to construct a compact PCS clock.

DOI
10.1142/9789812838223_0038

Related papers

Formation of Ramsey fringes based on pulsed coherent light storage

Bo Yan, Yisheng Ma, Yuzhu Wang

We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low $Q$ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.

arXiv:0810.0623•Physical Review A•Jun 11, 2009•6 citations

LASER COOLING OF ATOMS AND ITS APPLICATION IN FREQUENCY STANDARDS

Vladilen S Letokhov, Vladimir G. Minogin

The results of studies into the laser cooling of atoms have been summarized and the possibilities of application of cold atoms in frequency standards have been considered. It has been shown that the optical frequency standard on the basis of laser-cooled atoms Mg, Ca or Sr may have the long-term stability of about 10-15.

Le Journal de Physique Colloques•Dec 1, 1981•2 citations

RAMAN-RAMSEY Cs CELL ATOMIC CLOCK

Rodolphe Boudot, Stéphane Guérandel, N. Castagna +4 more

A Raman-Ramsey Cs cell atomic clock based on Coherent Population Trapping is studied. High contrasts and narrow width Ramsey fringes are achieved by combining an original double-lambda scheme and a pulsed interrogation technique. The pulsed method allows a strong reduction of the light shift effect and avoids the power broadening. Removing a drift attributed to the cell, the clock frequency stability has been measured to be 7 × 10 -13 τ -1/2 .

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

High-stability compact atomic clock based on isotropic laser cooling

François-Xavier Esnault, David Holleville, Nicolas Rossetto +2 more

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

Physical Review A•Sep 29, 2010•85 citations

Technique of pulsed optical pumping and pulsed excitation of microwave resonances using the Ramsey scheme in a 87Rb cell with a buffer gas

V. N. Baryshev, M. S. Aleynikov, G. V. Osipenko +1 more

A laboratory prototype of a compact quantum frequency standard based on a rubidium vapour cell with pulsed laser pumping is developed. With significantly smaller overall dimensions (a volume of ∼10 L and a mass of ∼10 kg), the frequency standard is expected to have the short-term instability comparable with that of the commercial passive hydrogen masers and even the laboratory fountain-type atomic clocks based on cold atoms. The advantages of the technique of pulsed optical pumping and pulsed excitation of microwave resonances over the traditional techniques of double radio-optical resonance detection are substantiated. The results of the experimental study of pulsed optical pumping of a rubidium cell with a mixture of buffer Ar – Ne gases implemented at the VNIIFTRI are presented, the Ramsey resonances are obtained, and the process of optimising the contrast of the central resonance peak is described.

Quantum Electronics•May 29, 2018•12 citations

Ramsey-coherent population trapping Cs atomic clock based on lin∥lin optical pumping with dispersion detection*

Pengfei Cheng, Jianwei Zhang, Lijun Wang

A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.

Chinese Physics B•Jul 1, 2019•9 citations
In this paper we proposed a frequency standard based on pulsed coherent storage (PCS), the basic idea of the PCS scheme is combining the information storage technique with the optical pumping method. It shows that the Ramsey pattern is printed on the coherence of the atom states, then is detected in the form of the retrieval light. The proposed PCS frequency standards are free of light shifts, low Q requirement, high signal contrast and low noise background. The estimated frequency stability is 2 × 10 -14 in 1 second. Meanwhile we report the progress in laser cooling of atoms in an integrating sphere, some experimental results are given. This cooling method provides a robust source which is suitable to construct a compact PCS clock.
We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low QQQ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.
We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.
A laboratory prototype of a compact quantum frequency standard based on a rubidium vapour cell with pulsed laser pumping is developed. With significantly smaller overall dimensions (a volume of ∼10 L and a mass of ∼10 kg), the frequency standard is expected to have the short-term instability comparable with that of the commercial passive hydrogen masers and even the laboratory fountain-type atomic clocks based on cold atoms. The advantages of the technique of pulsed optical pumping and pulsed excitation of microwave resonances over the traditional techniques of double radio-optical resonance detection are substantiated. The results of the experimental study of pulsed optical pumping of a rubidium cell with a mixture of buffer Ar – Ne gases implemented at the VNIIFTRI are presented, the Ramsey resonances are obtained, and the process of optimising the contrast of the central resonance peak is described.
A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.