Journal of the Optical Society of America B

Sub-shot-noise frequency-modulation spectroscopy by use of amplitude-squeezed light from semiconductor lasers

Steven Kasapi, Seema Lathi, Y. Yamamoto

Published Feb 1, 2000• 21 citations
Publisher

Abstract

We have demonstrated sub-shot-noise FM spectroscopy on thermal cesium atoms, using amplitude-squeezed light from a semiconductor laser. The light source used in our experiment was a custom-made GaAs transverse junction stripe semiconductor laser featuring broadband amplitude squeezing and a large FM bandwidth. We have also developed a new technique by which a semiconductor laser can be frequency modulated with infinitesimally small residual AM and with complete preservation of the squeezed-amplitude fluctuations.

DOI
10.1364/josab.17.000275

Related papers

Amplitude-squeezed, frequency-modulated, tunable, diode-laser-based source for sub-shot-noise FM spectroscopy

Steven Kasapi, Seema Lathi, Y. Yamamoto

We have developed a frequency-modulated, tunable, amplitude-squeezed, diode-laser-based source and used it to perform FM spectroscopy on rubidium. The setup consists of a free-running diode laser injection locked by a frequency-stabilized, current-modulated diode laser. The injection-locked slave laser beam adopted the frequency spectrum of the master laser beam while rejecting residual AM in the master laser beam by more than 50 dB. Injection locking also enhanced amplitude squeezing in the slave laser beam by suppressing uncorrelated longitudinal sidemodes. The noise floor of the measurement was 0.8 dB below the shot-noise level.

Optics Letters•Apr 1, 1997•49 citations

Subshot noise FM spectroscopy with an amplitude-squeezed diode laser at room temperature

Steven Kasapi, Seema Lathi, Y. Yamamoto

We have developed a sub-shot-noise diode laser system and used it to perform sub-shot-noise FM spectroscopy. By inducing FM sidebands on a direct-current modulated external-cavity diode laser and injection locking a slave laser, we have suppressed the residual AM in the master by 50 dB and achieved a noise level of 0.8 dB below the shot-noise level. We expect that such techniques will provide useful and practical tools for future precision measurements and novel atom-photon interaction experiments.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 26, 1995•1 citation

Sub-shot-noise FM noise spectroscopy of trapped rubidium atoms

Steven Kasapi, Seema Lathi, Y. Yamamoto

We demonstrate that the large FM noise of a semiconductor laser can be combined with a squeezed AM noise spectrum to make a sub-shot-noise, FM-noise-based spectroscopic measurement. In particular, we probe the spectrum of magneto-optically trapped and cooled rubidium atoms using the FM noise on squeezed AM background noise. The natural absorption line as well as a stimulated Raman transition are clearly visible in the FM-to-AM converted noise even though the signal is below the classical shot-noise level.

Journal of the Optical Society of America B•Oct 1, 1998•5 citations

Atomic spectroscopy with squeezed light

Harry J. Kimble, Eugene Simon Polzik, J. Carri

A frequency tunable source of squeezed light has been developed for application to a variety of problems in atomic physics. The basic experimental arrangement consists of a subthreshold optical parametric oscillator (OPO) that is pumped by the frequency-doubled output of a titanium-sapphire laser. Squeezed light with continuous tunability of 2 GHz has been generated with a directly observed nonclassical noise reduction of 5.0 dB relative to the vacuumstate limit in a balanced homodyne detector (5.2 dB when corrected for detector noise). Although our source is potentially broadly tunable over the noncritical phase-matching bandwidth of potassium niobate, current research has concentrated on operation at 852 nm for excitation of the D2 line of atomic cesium. Relative to the usual quantum limit associated with vacuumstate fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in FM saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB after correction for detector noise.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

High-precision cavity spectroscopy using high-frequency squeezed light

J. Junker, D. M. Wilken, Elanor H. Huntington +1 more

In this article, we present a novel spectroscopy technique that improves the signal-to-shot-noise ratio without the need to increase the laser power. Detrimental effects by technical noise sources are avoided by frequency-modulation techniques (frequency up-shifting). Superimposing the signal on non-classical states of light leads to a reduced quantum noise floor. Our method reveals in a proof-of-concept experiment small signals at Hz to kHz frequencies even below the shot noise limit. Our theoretical calculations fully support our experimental findings. The proposed technique is interesting for applications such as high-precision cavity spectroscopy, e.g., for explosive trace gas detection where the specific gas might set an upper limit for the laser power employed.

Optics Express•Jan 15, 2021•12 citations

Sub-Shot-Noise laser Doppler Anemometry with Amplitude-Squeezed Light

Yongqing Li, Peter Lynam, Min Xiao +1 more

Amplitude-squeezed light from a quantum-well semiconductor laser with weak optical feedback from a highly dispersive grating is employed for laser Doppler anemometry. Up to 2 dB noise reduction below the shot-noise level is observed with a feedback factor of $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$. Enhanced sensitivity is demonstrated in the Doppler measurement of a gas flow velocity with an improvement in the signal to noise ratio of 1.0 dB above the shot-noise limit.

Physical Review Letters•Apr 21, 1997•58 citations
We have demonstrated sub-shot-noise FM spectroscopy on thermal cesium atoms, using amplitude-squeezed light from a semiconductor laser. The light source used in our experiment was a custom-made GaAs transverse junction stripe semiconductor laser featuring broadband amplitude squeezing and a large FM bandwidth. We have also developed a new technique by which a semiconductor laser can be frequency modulated with infinitesimally small residual AM and with complete preservation of the squeezed-amplitude fluctuations.
We have developed a frequency-modulated, tunable, amplitude-squeezed, diode-laser-based source and used it to perform FM spectroscopy on rubidium. The setup consists of a free-running diode laser injection locked by a frequency-stabilized, current-modulated diode laser. The injection-locked slave laser beam adopted the frequency spectrum of the master laser beam while rejecting residual AM in the master laser beam by more than 50 dB. Injection locking also enhanced amplitude squeezing in the slave laser beam by suppressing uncorrelated longitudinal sidemodes. The noise floor of the measurement was 0.8 dB below the shot-noise level.
We have developed a sub-shot-noise diode laser system and used it to perform sub-shot-noise FM spectroscopy. By inducing FM sidebands on a direct-current modulated external-cavity diode laser and injection locking a slave laser, we have suppressed the residual AM in the master by 50 dB and achieved a noise level of 0.8 dB below the shot-noise level. We expect that such techniques will provide useful and practical tools for future precision measurements and novel atom-photon interaction experiments.
We demonstrate that the large FM noise of a semiconductor laser can be combined with a squeezed AM noise spectrum to make a sub-shot-noise, FM-noise-based spectroscopic measurement. In particular, we probe the spectrum of magneto-optically trapped and cooled rubidium atoms using the FM noise on squeezed AM background noise. The natural absorption line as well as a stimulated Raman transition are clearly visible in the FM-to-AM converted noise even though the signal is below the classical shot-noise level.
A frequency tunable source of squeezed light has been developed for application to a variety of problems in atomic physics. The basic experimental arrangement consists of a subthreshold optical parametric oscillator (OPO) that is pumped by the frequency-doubled output of a titanium-sapphire laser. Squeezed light with continuous tunability of 2 GHz has been generated with a directly observed nonclassical noise reduction of 5.0 dB relative to the vacuumstate limit in a balanced homodyne detector (5.2 dB when corrected for detector noise). Although our source is potentially broadly tunable over the noncritical phase-matching bandwidth of potassium niobate, current research has concentrated on operation at 852 nm for excitation of the D2 line of atomic cesium. Relative to the usual quantum limit associated with vacuumstate fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in FM saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB after correction for detector noise.
In this article, we present a novel spectroscopy technique that improves the signal-to-shot-noise ratio without the need to increase the laser power. Detrimental effects by technical noise sources are avoided by frequency-modulation techniques (frequency up-shifting). Superimposing the signal on non-classical states of light leads to a reduced quantum noise floor. Our method reveals in a proof-of-concept experiment small signals at Hz to kHz frequencies even below the shot noise limit. Our theoretical calculations fully support our experimental findings. The proposed technique is interesting for applications such as high-precision cavity spectroscopy, e.g., for explosive trace gas detection where the specific gas might set an upper limit for the laser power employed.
Amplitude-squeezed light from a quantum-well semiconductor laser with weak optical feedback from a highly dispersive grating is employed for laser Doppler anemometry. Up to 2 dB noise reduction below the shot-noise level is observed with a feedback factor of $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$. Enhanced sensitivity is demonstrated in the Doppler measurement of a gas flow velocity with an improvement in the signal to noise ratio of 1.0 dB above the shot-noise limit.