Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Atomic spectroscopy with squeezed light

Harry J. Kimble, Eugene Simon Polzik, J. Carri

Published Jan 1, 1992• 0 citations
Publisher

Abstract

A frequency tunable source of squeezed light has been developed for application to a variety of problems in atomic physics. The basic experimental arrangement consists of a subthreshold optical parametric oscillator (OPO) that is pumped by the frequency-doubled output of a titanium-sapphire laser. Squeezed light with continuous tunability of 2 GHz has been generated with a directly observed nonclassical noise reduction of 5.0 dB relative to the vacuumstate limit in a balanced homodyne detector (5.2 dB when corrected for detector noise). Although our source is potentially broadly tunable over the noncritical phase-matching bandwidth of potassium niobate, current research has concentrated on operation at 852 nm for excitation of the D2 line of atomic cesium. Relative to the usual quantum limit associated with vacuumstate fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in FM saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB after correction for detector noise.

DOI
10.1364/oam.1992.fv2

Related papers

Spectroscopy with squeezed light

Eugene Simon Polzik, J. Carri, Harry J. Kimble

A frequency-tunable source of squeezed light is employed for spectroscopic measurements of atomic cesium. Relative to the usual quantum limit associated with vacuum-state fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB inferred after correcting for detector thermal noise.

Physical Review Letters•May 18, 1992•443 citations

Frequency-tunable squeezed light for spectroscopy

Eugene Simon Polzik, J. Carri, Harry J. Kimble

A frequency-tunable source of squeezed light would allow investigations of the atom-field interaction in a regime where fundamental new phenomena have been predicted.1 There are also opportunities for spectroscopy with sensitivity beyond the shot-noise limit. Toward these objectives, in our experiment we employ a single-frequency Ti-sapphire laser with tuning optimized around 852 nm (cesium resonance transition). The infrared output of the laser is frequency doubled in an external buildup cavity with a KNbO3 crystal as the nonlinear element. Efficient doubling provides 0.65 W of tunable blue output for 1.35 W of infrared input. This blue output is then used to pump an optical parametric oscillator (OPO) containing a second KNbO3 crystal for downconversion back to the infrared. The high power of the blue pump that we have achieved and the large nonlinearity of KNbO3 allows us to employ an OPO that is resonant only for the subharmonic infrared light. This design facilitates tuning of the OPO compared with the case in which the blue pump and the infrared are both resonant. The doubling cavity, OPO, and laser itself are locked relative to a stable reference cavity by an rf sideband technique, thus providing the possibility for tunability of the system with a single knob.

Annual Meeting Optical Society of America•Jan 1, 1991•0 citations

Generation of squeezed vacuum on cesium D2 line down to kilohertz range

Jianfeng Tian, Guan-Hua Zuo, Yuchi Zhang +3 more

We report the experimental generation of a squeezed vacuum at frequencies ranging from 2.5 kHz to 200 kHz that is resonant on the cesium D2 line by using a below-threshold optical parametric oscillator (OPO). The OPO is based on a periodically-poled KTiOPO 4 (PPKTP) crystal that is pumped using a bow-tie four-mirror ring frequency doubler. The phase of the squeezed light is controlled using a quantum noise locking technique. At a pump power of 115 mW, maximum quadrature phase squeezing of 3.5 dB and anti-squeezing of 7.5 dB are detected using a home-made balanced homodyne detector. This squeezed vacuum at an atomic transition in the kilohertz range is an ideal quantum source for quantum metrology of enhancing measurement precision, especially for ultra-sensitive measurement of weak magnetic fields when using a Cs atomic magnetometer in the audio frequency range.

Chinese Physics B•Dec 1, 2017•10 citations

Squeezing with for atomic physics and spectroscopy

Jens Lykke Sørensen, Jan Hald, Nils B. Jørgensen +2 more

Parametric downconversion in media has, so far, proved to be the most effective way of generating squeezed light. The development of frequency tunable sources of such non-classical light opens up novel possibilities in atomic physics and spectroscopy. A brief overview of the results in this area of quantum optics is given, and a new experiment aimed on subshot-noise measurement of atomic orientation is described. We report a preliminary 5 dB quantum noise reduction observed directly around the 917 nm Cs line. We introduce a figure of merit for the medium utilized for squeezed light generation in an optical parametric oscillator and evaluate some available nonlinear media from this perspective.

Quantum and Semiclassical Optics Journal of the European Optical Society Part B•Apr 1, 1997•6 citations

Observation of Squeezed Light in the 2 μm Region

Georgia L. Mansell, T. McRae, P. A. Altin +5 more

We present the generation and detection of squeezed light in the 2 μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1 dB of squeezing and 10.5±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.

arXiv:1805.12128•Physical Review Letters•May 17, 2018•42 citations

Generation of squeezed states at low analysis frequencies

Xin Wen, Yashuai Han, Liu Jin-Yu +3 more

Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.

Acta Physica Sinica•Jan 1, 2018•4 citations
A frequency tunable source of squeezed light has been developed for application to a variety of problems in atomic physics. The basic experimental arrangement consists of a subthreshold optical parametric oscillator (OPO) that is pumped by the frequency-doubled output of a titanium-sapphire laser. Squeezed light with continuous tunability of 2 GHz has been generated with a directly observed nonclassical noise reduction of 5.0 dB relative to the vacuumstate limit in a balanced homodyne detector (5.2 dB when corrected for detector noise). Although our source is potentially broadly tunable over the noncritical phase-matching bandwidth of potassium niobate, current research has concentrated on operation at 852 nm for excitation of the D2 line of atomic cesium. Relative to the usual quantum limit associated with vacuumstate fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in FM saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB after correction for detector noise.
A frequency-tunable source of squeezed light would allow investigations of the atom-field interaction in a regime where fundamental new phenomena have been predicted.1 There are also opportunities for spectroscopy with sensitivity beyond the shot-noise limit. Toward these objectives, in our experiment we employ a single-frequency Ti-sapphire laser with tuning optimized around 852 nm (cesium resonance transition). The infrared output of the laser is frequency doubled in an external buildup cavity with a KNbO3 crystal as the nonlinear element. Efficient doubling provides 0.65 W of tunable blue output for 1.35 W of infrared input. This blue output is then used to pump an optical parametric oscillator (OPO) containing a second KNbO3 crystal for downconversion back to the infrared. The high power of the blue pump that we have achieved and the large nonlinearity of KNbO3 allows us to employ an OPO that is resonant only for the subharmonic infrared light. This design facilitates tuning of the OPO compared with the case in which the blue pump and the infrared are both resonant. The doubling cavity, OPO, and laser itself are locked relative to a stable reference cavity by an rf sideband technique, thus providing the possibility for tunability of the system with a single knob.
We report the experimental generation of a squeezed vacuum at frequencies ranging from 2.5 kHz to 200 kHz that is resonant on the cesium D2 line by using a below-threshold optical parametric oscillator (OPO). The OPO is based on a periodically-poled KTiOPO 4 (PPKTP) crystal that is pumped using a bow-tie four-mirror ring frequency doubler. The phase of the squeezed light is controlled using a quantum noise locking technique. At a pump power of 115 mW, maximum quadrature phase squeezing of 3.5 dB and anti-squeezing of 7.5 dB are detected using a home-made balanced homodyne detector. This squeezed vacuum at an atomic transition in the kilohertz range is an ideal quantum source for quantum metrology of enhancing measurement precision, especially for ultra-sensitive measurement of weak magnetic fields when using a Cs atomic magnetometer in the audio frequency range.
Parametric downconversion in media has, so far, proved to be the most effective way of generating squeezed light. The development of frequency tunable sources of such non-classical light opens up novel possibilities in atomic physics and spectroscopy. A brief overview of the results in this area of quantum optics is given, and a new experiment aimed on subshot-noise measurement of atomic orientation is described. We report a preliminary 5 dB quantum noise reduction observed directly around the 917 nm Cs line. We introduce a figure of merit for the medium utilized for squeezed light generation in an optical parametric oscillator and evaluate some available nonlinear media from this perspective.
We present the generation and detection of squeezed light in the 2 μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1 dB of squeezing and 10.5±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.