Spectroscopy Letters

Characterizing Low Light Level Signals with the Triggered Delayed Photocount Distribution

Manuel P. Cagigal, T. Ariste

Published Mar 1, 1989• 2 citations
Publisher

Abstract

The theoretical expression of the first-order factorial moment of a triggered delayed photocount distribution and a description of its SNR have been developed. We explain the adventages of this thecnique, in comparison with the second-order correlation function, when we measured a temporal signal under low light level. We derived the theoretical errors involved in determining a parameter by measuring both functions for a signal with a periodically modulated intensity, since this kind of signals usually appear in spectroscopy. We conclude that the first-order factorial moment of a triggered delayed photocount distribution is a useful tool for characterizing a signal at low; light level conditions.

DOI
10.1080/00387018908053877

Related papers

Analysis of a light beam with a periodically modulated intensity by triggered photon counting

M. Á. Rebolledo, J. M. Alvarez, Julio Cesar Amare

Theoretical expressions for the factorial moments of the triggered photon-counting distribution that corresponds to a light beam with a periodically modulated intensity are derived. Two triggering procedures are considered: the time-window triggering procedure (which has been experimentally checked for Gaussian light by other authors) and the first-photopulse triggering procedure (which is a faster procedure). The theoretical expressions that correspond to the latter procedure are experimentally checked in this paper by using a square-wave signal. The errors involved in the analysis of the information contained in the light beam, when this information is obtained from the measurement of the first-order factorial moment, are studied.

Journal of the Optical Society of America A•Jan 1, 1986•6 citations

The Measurement of the First-order Factorial Moment of Double-triggered Photocount Distribution as an Alternative to Triple Correlation

Manuel P. Cagigal

The expression corresponding to the normalized first-order factorial moment (NFOFM) of a double triggered photocount distribution (DTPCD) has been developed. It is found that the NFOFM of a DTCPD has the spectral information of incident light corresponding to the third-order autocorrelation function. A theoretical error model was developed and checked by using a computer simulation method. We also compare the results obtained from the measurement of the NFOFM of a DTPCD with those obtained from the second- and third-order correlation functions.

Journal of Modern Optics•Aug 1, 1992•3 citations

Evaluation of triple correlation from triggered factorial moment measurement

Manuel P. Cagigal, Pedro M. Prieto

Triple-correlation values are obtained as a combination of second-order factorial moments of the triggered photocount distribution. The signal-to-noise ratio obtained from this kind of measurement is smaller than that obtained from direct calculation of the triple correlation for small time-delay values.

Optics Letters•Aug 15, 1992•1 citation

Analysis of a periodically modulated light beam by measurement of the moment-generating function of the number of photopulses

Felipe González, Fernando G. Moreno

We analyze a low-intensity square-wave modulated light signal by measuring the moment-generating function of the number of photopulses, Qn(s, T). The behavior of the experimental errors in the determination of the period and the modulation factor of the signal is studied by means of a theoretical error model. A set of experimental measurements was carried out, and the results found through the Qn(s, T) measurement and by the normalized second-order factorial moment n(2)(T) are compared.

Journal of the Optical Society of America B•Oct 1, 1992•1 citation

Statistical properties of triggered photocounting distribution

Takeaki Yoshimura, Toshiro Nakajima, Nobuo Wakabayashi

The triggered photocounting distribution (TPCD) of practical fields has been investigated. The moment generating function and the factorial moment are exactly deduced from theory and experimentally justified by the measurement of Gaussian-Lorentzian light. It is found that the first-order factorial moment of the TPCD has the spectral information of incident light corresponding to the second-order factorial moment of ordinary photocounting distribution.

Applied Optics•Sep 1, 1981•12 citations

Signal-to-noise ratio improvement by measuring the moment generating function of the number of photopulses for low intensity periodical signals

Fernando G. Moreno, Pedro J. Valle, Jose Maria Saiz +1 more

The authors show, through the analysis of a periodically modulated light beam with a square profile, the improvement in the signal-to-noise ratio by measuring the moment generating function of the number of photopulses, Q n (s, T), with respect to the measurement of the second normalized factorial moment, n (2) (T). An experimental verification in the low light level range (1-10 photoelectrons per period) for different values of the modulation factor has been made. The results and some conclusions are presented.

Pure and Applied Optics Journal of the European Optical Society Part A•Sep 1, 1992•1 citation
The theoretical expression of the first-order factorial moment of a triggered delayed photocount distribution and a description of its SNR have been developed. We explain the adventages of this thecnique, in comparison with the second-order correlation function, when we measured a temporal signal under low light level. We derived the theoretical errors involved in determining a parameter by measuring both functions for a signal with a periodically modulated intensity, since this kind of signals usually appear in spectroscopy. We conclude that the first-order factorial moment of a triggered delayed photocount distribution is a useful tool for characterizing a signal at low; light level conditions.
Theoretical expressions for the factorial moments of the triggered photon-counting distribution that corresponds to a light beam with a periodically modulated intensity are derived. Two triggering procedures are considered: the time-window triggering procedure (which has been experimentally checked for Gaussian light by other authors) and the first-photopulse triggering procedure (which is a faster procedure). The theoretical expressions that correspond to the latter procedure are experimentally checked in this paper by using a square-wave signal. The errors involved in the analysis of the information contained in the light beam, when this information is obtained from the measurement of the first-order factorial moment, are studied.
The expression corresponding to the normalized first-order factorial moment (NFOFM) of a double triggered photocount distribution (DTPCD) has been developed. It is found that the NFOFM of a DTCPD has the spectral information of incident light corresponding to the third-order autocorrelation function. A theoretical error model was developed and checked by using a computer simulation method. We also compare the results obtained from the measurement of the NFOFM of a DTPCD with those obtained from the second- and third-order correlation functions.
The authors show, through the analysis of a periodically modulated light beam with a square profile, the improvement in the signal-to-noise ratio by measuring the moment generating function of the number of photopulses, Q n (s, T), with respect to the measurement of the second normalized factorial moment, n (2) (T). An experimental verification in the low light level range (1-10 photoelectrons per period) for different values of the modulation factor has been made. The results and some conclusions are presented.