Optics Letters

Evaluation of triple correlation from triggered factorial moment measurement

Manuel P. Cagigal, Pedro M. Prieto

Published Aug 15, 1992• 1 citation
Publisher

Abstract

Triple-correlation values are obtained as a combination of second-order factorial moments of the triggered photocount distribution. The signal-to-noise ratio obtained from this kind of measurement is smaller than that obtained from direct calculation of the triple correlation for small time-delay values.
DOI
10.1364/ol.17.001137

Related papers

Characterizing Low Light Level Signals with the Triggered Delayed Photocount Distribution

Manuel P. Cagigal, T. Ariste

The theoretical expression of the first-order factorial moment of a triggered delayed photocount distribution and a description of its SNR have been developed. We explain the adventages of this thecnique, in comparison with the second-order correlation function, when we measured a temporal signal under low light level. We derived the theoretical errors involved in determining a parameter by measuring both functions for a signal with a periodically modulated intensity, since this kind of signals usually appear in spectroscopy. We conclude that the first-order factorial moment of a triggered delayed photocount distribution is a useful tool for characterizing a signal at low; light level conditions.

Spectroscopy Letters•Mar 1, 1989•2 citations

The Measurement of the Triggered Probability Density as an Alternative to the Direct Evaluation of the Triple Correlation

L. Vega, Manuel P. Cagigal, Pedro M. Prieto

Evaluations of the triple correlation function for different time delays are performed from combinations of the triggered probability density values corresponding to a series of counting times. This technique can only be applied to very low light level signals, but ultimately, the signal-to-noise ratio obtained by this method is better, for short time delays, than that obtained from a direct measurement of the triple correlation function.

Journal of Modern Optics•Mar 1, 1994•0 citations

The Measurement of the First-order Factorial Moment of Double-triggered Photocount Distribution as an Alternative to Triple Correlation

Manuel P. Cagigal

The expression corresponding to the normalized first-order factorial moment (NFOFM) of a double triggered photocount distribution (DTPCD) has been developed. It is found that the NFOFM of a DTCPD has the spectral information of incident light corresponding to the third-order autocorrelation function. A theoretical error model was developed and checked by using a computer simulation method. We also compare the results obtained from the measurement of the NFOFM of a DTPCD with those obtained from the second- and third-order correlation functions.

Journal of Modern Optics•Aug 1, 1992•3 citations

Autocorrelation evaluation from clipped photon detection

Manuel P. Cagigal, Pedro M. Prieto, L. Vega

We present two new techniques for estimating the autocorrelation function, based on the measurement of the mean number of clipped photocounts and on the calculation of the second-order factorial moment of a series of clipped data. The first procedure has the advantage of simplicity, although it produces a poor signal-to-noise ratio. On the other hand, the second technique gives a very good signal-to-noise ratio, when compared with other known methods.

Optics Letters•Apr 15, 1994•1 citation

The measurement of the photocount distribution of a low light level signal as an easy method to determine its factorial moments

Manuel P. Cagigal

Optics Communications•May 1, 1989•4 citations

Statistical properties of triggered photocounting distribution

Takeaki Yoshimura, Toshiro Nakajima, Nobuo Wakabayashi

The triggered photocounting distribution (TPCD) of practical fields has been investigated. The moment generating function and the factorial moment are exactly deduced from theory and experimentally justified by the measurement of Gaussian-Lorentzian light. It is found that the first-order factorial moment of the TPCD has the spectral information of incident light corresponding to the second-order factorial moment of ordinary photocounting distribution.

Applied Optics•Sep 1, 1981•12 citations
The theoretical expression of the first-order factorial moment of a triggered delayed photocount distribution and a description of its SNR have been developed. We explain the adventages of this thecnique, in comparison with the second-order correlation function, when we measured a temporal signal under low light level. We derived the theoretical errors involved in determining a parameter by measuring both functions for a signal with a periodically modulated intensity, since this kind of signals usually appear in spectroscopy. We conclude that the first-order factorial moment of a triggered delayed photocount distribution is a useful tool for characterizing a signal at low; light level conditions.
The expression corresponding to the normalized first-order factorial moment (NFOFM) of a double triggered photocount distribution (DTPCD) has been developed. It is found that the NFOFM of a DTCPD has the spectral information of incident light corresponding to the third-order autocorrelation function. A theoretical error model was developed and checked by using a computer simulation method. We also compare the results obtained from the measurement of the NFOFM of a DTPCD with those obtained from the second- and third-order correlation functions.