Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Surpassing the Amplifier Limit for Force Detection

Mark F. Bocko, Warren W. Johnson

Published May 17, 1982• 38 citations
Publisher

Abstract

A force-measuring system composed of a macroscopic harmonic oscillator, mechanical-electrical transducer, and linear amplifier is described and the sensitivity is calculated for a "back-action evasion" mode of operation. It is shown that it is possible to surpass the standard amplifier limit with this device, and the specific requirements to do so are given. These results may also apply to a quantum-limited amplifier and thus give the requirements to perform quantum-nondemolition measurements.

DOI
10.1103/physrevlett.48.1371

Related papers

Approaching the Quantum "Limit" for Force Detection

Warren W. Johnson, Mark F. Bocko

A system is proposed for detecting the effect of a weak classical force on a macroscopic mechanical oscillator. The novel feature is a type of ac bridge coupled to a SQUID amplifier. A detailed sensitivity calculation for one type of bridge excitation is reported which shows what is required to reach the standard quantum "limit." Another type of excitation should make it a "back-action evasion" device capable of exceeding the standard quantum "limit".

Physical Review Letters•Oct 26, 1981•43 citations

Phase-Sensitive Detection and the Back-Action Evasion of Amplifier Force Noise (Measurement Theory, Transducers, Antenna, Gravitational Radiation, Accelerometer).

Gary W. Spetz

Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.

Civil War Book Review•Jan 1, 1985•0 citations

On the measurement of a weak classical force coupled to a quantum-mechanical oscillator. I. Issues of principle

Carlton M. Caves, Kip S. Thorne, Ronald W. P. Drever +2 more

The monitoring of a quantum-mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. This paper reviews the standard techniques for monitoring the oscillator, and introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator. The standard method for monitoring the oscillator is the "amplitude-and-phase" method (position or momentum transducer with output fed through a narrow-band amplifier). The accuracy obtainable by this method is limited by the uncertainty principle ("standard quantum limit"). To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak classical force, but which cannot provide good accuracy in determining its precise time dependence. This paper considers extensively a new type of quantum nondemolition measurement---a "back-action-evading" measurement of the real part ${X}_{1}$ (or the imaginary part ${X}_{2}$) of the oscillator's complex amplitude. In principle ${X}_{1}$ can be measured "arbitrarily quickly and arbitrarily accurately," and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force. The authors describe explicit Gedanken experiments which demonstrate that ${X}_{1}$ can be measured arbitrarily quickly and arbitrarily accurately. In these experiments the measuring apparatus must be coupled to both the position (position transducer) and the momentum (momentum transducer) of the oscillator, and both couplings must be modulated sinusoidally. For a given measurement time the strength of the coupling determines the accuracy of the measurement; for arbitrarily strong coupling the measurement can be arbitrarily accurate. The "momentum transducer" is constructed by combining a "velocity transducer" with a "negative capacitor" or "negative spring." The modulated couplings are provided by an external, classical generator, which can be realized as a harmonic oscillator excited in an arbitrarily energetic, coherent state. One can avoid the use of two transducers by making "stroboscopic measurements" of ${X}_{1}$, in which one measures position (or momentum) at half-cycle intervals. Alternatively, one can make "continuous single-transducer" measurements of ${X}_{1}$ by modulating appropriately the output of a single transducer (position or momentum), and then filtering the output to pick out the information about ${X}_{1}$ and reject information about ${X}_{2}$. Continuous single-transducer measurements are useful in the case of weak coupling. In this case long measurement times are required to achieve good accuracy, and continuous single-transducer measurements are almost as good as perfectly coupled two-transducer measurements. Finally, the authors develop a theory of quantum nondemolition measurement for arbitrary systems. This paper (Paper I) concentrates on issues of principle; a sequel (Paper II) will consider issues of practice.

Reviews of Modern Physics•Apr 1, 1980•1,235 citations

On the measurement of a weak classical force coupled to a harmonic oscillator: experimental progress

Mark F. Bocko, Roberto Onofrio

Several high-precision physics experiments are approaching a level of sensitivity at which the intrinsic quantum nature of the experimental apparatus is the dominant source of fluctuations limiting the sensitivity of the measurements. This quantum limit is embodied by the Heisenberg uncertainty principle, which prohibits arbitrarily precise simultaneous measurements of two conjugate observables of a system but allows one-time measurements of a single observable with any precision. The dynamical evolution of a system immediately following a measurement limits the class of observables that may be measured repeatedly with arbitrary precision, with the influence of the measurement apparatus on the system being confined strictly to the conjugate observables. Observables having this feature, and the corresponding measurements performed on them have been named quantum nondemolition or back-action evasion observables. In a previous review (Caves et al., 1980, Rev. Mod. Phys. 52, 341) a quantum-mechanical analysis of quantum nondemolition measurements of a harmonic oscillator was presented. The present review summarizes the experimental progress on quantum nondemolition measurements and the classical models developed to describe and guide the development of practical implementations of quantum nondemolition measurements. The relationship between the classical and quantum theoretical models is also reviewed. The concept of quantum nondemolition and back-action evasion measurements originated in the context of measurements on a macroscopic mechanical harmonic oscillator, though these techniques may be useful in other experimental contexts as well, as is discussed in the last part of this review. [S0034-6861(96)00103-1]

Reviews of Modern Physics•Jul 1, 1996•197 citations

Noiseless signal amplification in an opto-mechanical transducer

Aleksandr A. Movsisian, Albert I. Nazmiev, Andrey B. Matsko +1 more

The high-sensitivity quantum detection of a resonant classical force acting on a quantum harmonic oscillator can be significantly improved by employing a resonant optical parametric transducer. This technique leverages the unique properties of parametric interactions to enhance the response of the measurement system while maintaining quantum-limited performance. We demonstrate that such a configuration not only enables quantum back-action evading (BAE) measurements, surpassing the Standard Quantum Limit (SQL) of sensitivity, it also provides a mechanism for noiseless amplification of the classical signal. The key to this enhancement lies in the ability of the parametric transducer to generate and separately measure the upper and lower modulation sidebands induced by the external force. By decoupling and analyzing these sidebands independently, the system becomes capable of amplifying the signal without introducing additional noise, effectively circumventing quantum measurement constraints.

arXiv:2506.02717•Optics Letters•Jul 22, 2025•1 citation

Optimization of sensitivity of an opto-mechanical transducer

A. N. Karpenko, Sergey P. Vyatchanin, Andrey B. Matsko

The Standard Quantum Limit (SQL) in classical force detection using mechanical systems arises from quantum back-action, which disturbs the oscillator’s evolution during measurement. We present a theoretical analysis of a scheme that enables broadband back-action evading (BAE) force sensing by employing a multidimensional optical transducer. The proposed system consists of a mechanical oscillator coupled to an optical structure supporting three distinct optical modes, with mode spacing approximately matched to the mechanical resonance. The central mode is coherently pumped, and the signal is extracted by monitoring the light emitted from the adjacent sideband modes. By selecting appropriate optical quadratures for detection and applying tailored post-processing to the measurement data, our approach suppresses back-action noise across a wide frequency range, enabling sensitivity beyond the SQL. The architecture can be interpreted as a composite system hosting quantum-mechanics-free subsystems (QMFS), which effectively isolate the measured observable from quantum fluctuations by exploiting correlations akin to those found in systems with engineered “negative mass” response. We also show that the adjacent sideband modes are entangled and discuss possible methods for detecting this entanglement. This configuration opens a promising route toward high-precision quantum metrology without being constrained by quantum measurement noise.

•Mar 5, 2026•1 citation
A force-measuring system composed of a macroscopic harmonic oscillator, mechanical-electrical transducer, and linear amplifier is described and the sensitivity is calculated for a "back-action evasion" mode of operation. It is shown that it is possible to surpass the standard amplifier limit with this device, and the specific requirements to do so are given. These results may also apply to a quantum-limited amplifier and thus give the requirements to perform quantum-nondemolition measurements.
Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.
The monitoring of a quantum-mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. This paper reviews the standard techniques for monitoring the oscillator, and introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator. The standard method for monitoring the oscillator is the "amplitude-and-phase" method (position or momentum transducer with output fed through a narrow-band amplifier). The accuracy obtainable by this method is limited by the uncertainty principle ("standard quantum limit"). To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak classical force, but which cannot provide good accuracy in determining its precise time dependence. This paper considers extensively a new type of quantum nondemolition measurement---a "back-action-evading" measurement of the real part X1{X}_{1}X1​ (or the imaginary part X2{X}_{2}X2​) of the oscillator's complex amplitude. In principle X1{X}_{1}X1​ can be measured "arbitrarily quickly and arbitrarily accurately," and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force. The authors describe explicit Gedanken experiments which demonstrate that X1{X}_{1}X1​ can be measured arbitrarily quickly and arbitrarily accurately. In these experiments the measuring apparatus must be coupled to both the position (position transducer) and the momentum (momentum transducer) of the oscillator, and both couplings must be modulated sinusoidally. For a given measurement time the strength of the coupling determines the accuracy of the measurement; for arbitrarily strong coupling the measurement can be arbitrarily accurate. The "momentum transducer" is constructed by combining a "velocity transducer" with a "negative capacitor" or "negative spring." The modulated couplings are provided by an external, classical generator, which can be realized as a harmonic oscillator excited in an arbitrarily energetic, coherent state. One can avoid the use of two transducers by making "stroboscopic measurements" of X1{X}_{1}X1​, in which one measures position (or momentum) at half-cycle intervals. Alternatively, one can make "continuous single-transducer" measurements of X1{X}_{1}X1​ by modulating appropriately the output of a single transducer (position or momentum), and then filtering the output to pick out the information about X1{X}_{1}X1​ and reject information about X2{X}_{2}X2​. Continuous single-transducer measurements are useful in the case of weak coupling. In this case long measurement times are required to achieve good accuracy, and continuous single-transducer measurements are almost as good as perfectly coupled two-transducer measurements. Finally, the authors develop a theory of quantum nondemolition measurement for arbitrary systems. This paper (Paper I) concentrates on issues of principle; a sequel (Paper II) will consider issues of practice.
Several high-precision physics experiments are approaching a level of sensitivity at which the intrinsic quantum nature of the experimental apparatus is the dominant source of fluctuations limiting the sensitivity of the measurements. This quantum limit is embodied by the Heisenberg uncertainty principle, which prohibits arbitrarily precise simultaneous measurements of two conjugate observables of a system but allows one-time measurements of a single observable with any precision. The dynamical evolution of a system immediately following a measurement limits the class of observables that may be measured repeatedly with arbitrary precision, with the influence of the measurement apparatus on the system being confined strictly to the conjugate observables. Observables having this feature, and the corresponding measurements performed on them have been named quantum nondemolition or back-action evasion observables. In a previous review (Caves et al., 1980, Rev. Mod. Phys. 52, 341) a quantum-mechanical analysis of quantum nondemolition measurements of a harmonic oscillator was presented. The present review summarizes the experimental progress on quantum nondemolition measurements and the classical models developed to describe and guide the development of practical implementations of quantum nondemolition measurements. The relationship between the classical and quantum theoretical models is also reviewed. The concept of quantum nondemolition and back-action evasion measurements originated in the context of measurements on a macroscopic mechanical harmonic oscillator, though these techniques may be useful in other experimental contexts as well, as is discussed in the last part of this review. [S0034-6861(96)00103-1]
The high-sensitivity quantum detection of a resonant classical force acting on a quantum harmonic oscillator can be significantly improved by employing a resonant optical parametric transducer. This technique leverages the unique properties of parametric interactions to enhance the response of the measurement system while maintaining quantum-limited performance. We demonstrate that such a configuration not only enables quantum back-action evading (BAE) measurements, surpassing the Standard Quantum Limit (SQL) of sensitivity, it also provides a mechanism for noiseless amplification of the classical signal. The key to this enhancement lies in the ability of the parametric transducer to generate and separately measure the upper and lower modulation sidebands induced by the external force. By decoupling and analyzing these sidebands independently, the system becomes capable of amplifying the signal without introducing additional noise, effectively circumventing quantum measurement constraints.
The Standard Quantum Limit (SQL) in classical force detection using mechanical systems arises from quantum back-action, which disturbs the oscillator’s evolution during measurement. We present a theoretical analysis of a scheme that enables broadband back-action evading (BAE) force sensing by employing a multidimensional optical transducer. The proposed system consists of a mechanical oscillator coupled to an optical structure supporting three distinct optical modes, with mode spacing approximately matched to the mechanical resonance. The central mode is coherently pumped, and the signal is extracted by monitoring the light emitted from the adjacent sideband modes. By selecting appropriate optical quadratures for detection and applying tailored post-processing to the measurement data, our approach suppresses back-action noise across a wide frequency range, enabling sensitivity beyond the SQL. The architecture can be interpreted as a composite system hosting quantum-mechanics-free subsystems (QMFS), which effectively isolate the measured observable from quantum fluctuations by exploiting correlations akin to those found in systems with engineered “negative mass” response. We also show that the adjacent sideband modes are entangled and discuss possible methods for detecting this entanglement. This configuration opens a promising route toward high-precision quantum metrology without being constrained by quantum measurement noise.