Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Prospect for development of a pulsed CPT Raman Ramsey clock using atomic vapor

G. S. Pati, Fredrik K. Fatemi, Mark Bashkansky, M. S. Shahriar

Published Feb 11, 2010• 2 citations
Publisher

Abstract

The phenomenon of all-optical Ramsey interference using pulsed coherent population trapping (CPT) beams provides a new avenue for developing frequency standards using atomic vapor. In this study, we show that frequency narrowed Ramsey fringes can be produced in rubidium vapor without the effect of power broadening. We observed fringes of width as narrow as 1 kHz using a buffer-gas filled rubidium cell. A compact injection-locked laser (ILL) system was used to generate CPT beams. Studies also show that ac Stark effect on Ramsey fringes can be reduced, and higher frequency stability can be achieved in a clock application. The results are encouraging to propose an architecture for development of a pulsed CPT Ramsey clock. In this paper, we also provide related discussions on clock frequency stability, and our plans for future experiments.

DOI
10.1117/12.848638

Related papers

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•86 citations

Optical Ramsey interference and its performance in D1 line excitation in rubidium vapor for implementation of a vapor cell clock

G. S. Pati, Fredrik K. Fatemi, Mark Bashkansky +1 more

Pulsed coherent population trapping in atomic vapor provides a convenient method for generating frequency narrowed atomic resonance using Ramsey interference. Here, we present our experimental results showing high-contrast and sub-kilohertz Ramsey interference fringes produced by coherently prepared 85Rb atoms using Raman excitation formed in D1 line transitions. A test system for atomic clock has been constructed to measure light shift for both continuous and pulsed Raman excitation cases. Our measurements show that light shift measured using pulsed Raman excitation, is reduced compared to the continuous excitation case. Our ability to measure light shift is currently limited by the resolution of the frequency counter, and performance of the locking electronics used.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 10, 2011•6 citations

Observation of Raman–Ramsey Fringes With Optical CPT Pulses

T. Zanon-Willette, S. Trémine, Stéphane Guérandel +4 more

The Ramsey method has been applied by means of optical coherent population trapping (CPT) pulses through a cesium vapor cell with N/sub 2/ buffer gas at room temperature, using two phase-locked lasers. With this method, CPT resonance spectral widths are no longer limited by optical saturation and collision effects, but only depend on free evolution time between the two pulses. A fringe width below 100 Hz is reported. Experimental Raman-Ramsey fringes are analyzed using the classical wavefunction formalism.

IEEE Transactions on Instrumentation and Measurement•Mar 21, 2005•42 citations

Raman–Ramsey Interaction for Coherent Population Trapping Cs Clock

Stéphane Guérandel, T. Zanon-Willette, N. Castagna +4 more

A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of$3.5 \times 10^{-12}t^{-1/2}$is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.

IEEE Transactions on Instrumentation and Measurement•Mar 16, 2007•43 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•6 citations

Observation of Ramsey fringes with optical CPT pulses

T. Zanon-Willette, Stéphane Guérandel, Emeric de Clercq +3 more

The linewidth of CPT atomic resonances observed in a vapor cell are usually limited by optical saturation and collisions due to buffer gas. We have applied here the Ramsey method with optical CPT pulses generated by a phase-locked device. Fringes are then produced giving narrow atomic signals only dependent on interrogation time between the two pulses. The possibility to obtain narrow fringe widths below 100 Hz with short or long pulses is shown experimentally and analysed using the classical Schrodinger state representation.

European Frequency and Time Forum•Jan 1, 2004•3 citations
The phenomenon of all-optical Ramsey interference using pulsed coherent population trapping (CPT) beams provides a new avenue for developing frequency standards using atomic vapor. In this study, we show that frequency narrowed Ramsey fringes can be produced in rubidium vapor without the effect of power broadening. We observed fringes of width as narrow as 1 kHz using a buffer-gas filled rubidium cell. A compact injection-locked laser (ILL) system was used to generate CPT beams. Studies also show that ac Stark effect on Ramsey fringes can be reduced, and higher frequency stability can be achieved in a clock application. The results are encouraging to propose an architecture for development of a pulsed CPT Ramsey clock. In this paper, we also provide related discussions on clock frequency stability, and our plans for future experiments.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
Pulsed coherent population trapping in atomic vapor provides a convenient method for generating frequency narrowed atomic resonance using Ramsey interference. Here, we present our experimental results showing high-contrast and sub-kilohertz Ramsey interference fringes produced by coherently prepared 85Rb atoms using Raman excitation formed in D1 line transitions. A test system for atomic clock has been constructed to measure light shift for both continuous and pulsed Raman excitation cases. Our measurements show that light shift measured using pulsed Raman excitation, is reduced compared to the continuous excitation case. Our ability to measure light shift is currently limited by the resolution of the frequency counter, and performance of the locking electronics used.
The Ramsey method has been applied by means of optical coherent population trapping (CPT) pulses through a cesium vapor cell with N/sub 2/ buffer gas at room temperature, using two phase-locked lasers. With this method, CPT resonance spectral widths are no longer limited by optical saturation and collision effects, but only depend on free evolution time between the two pulses. A fringe width below 100 Hz is reported. Experimental Raman-Ramsey fringes are analyzed using the classical wavefunction formalism.
A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of3.5×10−12t−1/23.5 \times 10^{-12}t^{-1/2}3.5×10−12t−1/2is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.
The linewidth of CPT atomic resonances observed in a vapor cell are usually limited by optical saturation and collisions due to buffer gas. We have applied here the Ramsey method with optical CPT pulses generated by a phase-locked device. Fringes are then produced giving narrow atomic signals only dependent on interrogation time between the two pulses. The possibility to obtain narrow fringe widths below 100 Hz with short or long pulses is shown experimentally and analysed using the classical Schrodinger state representation.