Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Journal of Quantum Information

SYSTEMATIC STUDY OF THE PDC SPECKLE STRUCTURE FOR QUANTUM IMAGING APPLICATIONS

G. Brida, Marco Genovese, Alice Meda, Ivano Ruo Berchera, E. Predazzi

Published Jan 1, 2009• 14 citations
Publisher

Abstract

Sub shot noise imaging of weak object by exploiting Parametric Down Converted light represents a very interesting technological development. A precise characterization of PDC speckle structure in dependence of pump beam parameters is a fundamental tool for this application. In this paper we present a first set of data addressed to this purpose.

DOI
10.1142/s0219749909004876

Related papers

Systematic study of the PDC speckle structure for quantum imaging applications

G. Brida, Alice Meda, Marco Genovese +2 more

Speckle structure of parametric down conversion light has recently received much attention owing to its relevance in view of applications to quantum imaging. The possibility of tailoring the speckle size by acting on the pump properties is an interesting tool for the applications to quantum imaging and in particular to the detection of a weak object under the shot-noise limit. Here we present a systematic detailed experimental study of the speckle structure produced in type II PDC with particular attention to its variation with pump beam properties.

arXiv:0802.2672•Journal of Modern Optics•Jan 20, 2009•29 citations

Tailoring PDC speckle structure

G. Brida, Marco Genovese, Meda, A. +2 more

Speckle structure of parametric down conversion light has recently received a large attention due to relevance in view of applications to quantum imaging The possibility of tailoring the speckle size by acting on the pump properties is an interesting tool for the applications to quantum imaging and in particular to the detection of weak object under shot-noise limit. Here we present a systematic detailed experimental study of the speckle structure produced in type II PDC with particular attention to its variation with pump beam properties.

arXiv:0809.5152•Sep 30, 2008•7 citations

Tailoring Parametric Down Conversion speckle structure toward quantum imaging of weak objects

G. Brida, Alice Meda, Marco Genovese +1 more

Speckle structure 1 of Parametric Down Conversion (PDC) has recently received a large attention due to the relevance in view of applications to quantum imaging. The possibility of tailoring the speckle size by acting on the pump intensity and dimensions is an interesting tool for the applications to quantum imaging and in particular to the detection of weak objects under shot-noise limit. In this paper we report a systematic detailed study of the speckle structure in particular of the one in type II PDC, with attention to its variation with pump beam characteristics (power and radius).

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 5, 2008•0 citations

Exploiting PDC spatial correlations for innovative quantum imaging protocols

Marco Genovese, G. Brida, Alice Meda +1 more

Quantum properties of the optical field represent a resource of the utmost relevance for the development of quantum technologies, allowing unprecedented results in disciplines ranging from quantum information and metrology to quantum imaging. Spatial quantum correlations generated by of parametric down conversion (PDC) represents a tool for quantum imaging because they are intrinsically multimode, a requirement for obtaining large degree of correlation over small portions of the beams, allowing to register the spatial structure of an object. In particular a very interesting example is provided by the detection of weak objects, a result that could have important practical applications. The principle of this technique is to take advantage of the correlation in the noise of two conjugated branches of PDC emission: in fact, subtracting the noise measured on one branch from the image of a weak object obtained in the other branch, the image of the object, eventually previously hidden in the noise, could be restored. Here, after a general summary of quantum imaging techniques, firstly we will show how we have reached a sub shot noise regime and then improved this result up to reach a regime where it was possible to achieve the first experimental realisation of sub shot noise imaging of a weak absorbing object.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 16, 2011•1 citation

Experimental Sub-shot Noise Quantum Imaging versus Differential Classical Imaging

G. Brida, Marco Genovese, E. Monticone +3 more

Sub-Shot Noise quantum imaging is a novel quantum method allowing in principle to recover the image of a weak absorbing object, even if illuminated by a low photon flux, with a signal to noise ratio larger than classical imaging techniques. Here we present the first realization of a genuine quantum imaging schemes exploiting correlation of twin beams produced by Parametric Down conversion. We compare its performances with respect to the corresponding classical scheme, showing a clear improvement of the sensitivity in the reconstruction of the absorbtion profile of a weak object.

International Conference on Quantum, Nano and Micro Technologies (ICQNM)•Feb 1, 2010•3 citations

Quantum imaging and the detection of weak objects

E. Brambilla, A. Gatti, Lucia Caspani +4 more

A recent experiment has demonstrated the quantum nature of spatial fluctuations in parametric down-conversion. We show theoretically and numerically that, by exploiting the sub-shot-noise character of spatial correlations, it is possible to detect weak amplitude objects with a sensitivity beyond the standard quantum limit.

•Jan 1, 2007•0 citations
Sub shot noise imaging of weak object by exploiting Parametric Down Converted light represents a very interesting technological development. A precise characterization of PDC speckle structure in dependence of pump beam parameters is a fundamental tool for this application. In this paper we present a first set of data addressed to this purpose.
Speckle structure of parametric down conversion light has recently received much attention owing to its relevance in view of applications to quantum imaging. The possibility of tailoring the speckle size by acting on the pump properties is an interesting tool for the applications to quantum imaging and in particular to the detection of a weak object under the shot-noise limit. Here we present a systematic detailed experimental study of the speckle structure produced in type II PDC with particular attention to its variation with pump beam properties.
Speckle structure of parametric down conversion light has recently received a large attention due to relevance in view of applications to quantum imaging The possibility of tailoring the speckle size by acting on the pump properties is an interesting tool for the applications to quantum imaging and in particular to the detection of weak object under shot-noise limit. Here we present a systematic detailed experimental study of the speckle structure produced in type II PDC with particular attention to its variation with pump beam properties.
Speckle structure 1 of Parametric Down Conversion (PDC) has recently received a large attention due to the relevance in view of applications to quantum imaging. The possibility of tailoring the speckle size by acting on the pump intensity and dimensions is an interesting tool for the applications to quantum imaging and in particular to the detection of weak objects under shot-noise limit. In this paper we report a systematic detailed study of the speckle structure in particular of the one in type II PDC, with attention to its variation with pump beam characteristics (power and radius).
Quantum properties of the optical field represent a resource of the utmost relevance for the development of quantum technologies, allowing unprecedented results in disciplines ranging from quantum information and metrology to quantum imaging. Spatial quantum correlations generated by of parametric down conversion (PDC) represents a tool for quantum imaging because they are intrinsically multimode, a requirement for obtaining large degree of correlation over small portions of the beams, allowing to register the spatial structure of an object. In particular a very interesting example is provided by the detection of weak objects, a result that could have important practical applications. The principle of this technique is to take advantage of the correlation in the noise of two conjugated branches of PDC emission: in fact, subtracting the noise measured on one branch from the image of a weak object obtained in the other branch, the image of the object, eventually previously hidden in the noise, could be restored. Here, after a general summary of quantum imaging techniques, firstly we will show how we have reached a sub shot noise regime and then improved this result up to reach a regime where it was possible to achieve the first experimental realisation of sub shot noise imaging of a weak absorbing object.
Sub-Shot Noise quantum imaging is a novel quantum method allowing in principle to recover the image of a weak absorbing object, even if illuminated by a low photon flux, with a signal to noise ratio larger than classical imaging techniques. Here we present the first realization of a genuine quantum imaging schemes exploiting correlation of twin beams produced by Parametric Down conversion. We compare its performances with respect to the corresponding classical scheme, showing a clear improvement of the sensitivity in the reconstruction of the absorbtion profile of a weak object.