We present an experimental investigation into non-stationary events that occur in a homodyne detection system. The importance of non-stationary events is that it is a possible mechanism preventing shot-noise-limited homodyne detection at low frequencies, a necessary condition that needs to be routinely fulfilled in order to detect squeezed states at these frequencies. These non-stationary events are thought to arise due to airborne dust passing through the laser beam paths. We show that these non-stationary events which occur in our laboratory environment can be minimised by placing the experiment in an airtight enclosure. Isolation against non-stationary events achieved improvement of the colour of the noise spectrum by 3dB at 10Hz towards a flat shot noise spectrum and improvement in the noise distribution of the signal towards a Gaussian distribution.
We present an experimental investigation into non-stationary events that occur in a homodyne detection system. The importance of non-stationary events is that it is a possible mechanism preventing shot-noise-limited homodyne detection at low frequencies, a necessary condition that needs to be routinely fulfilled in order to detect squeezed states at these frequencies. These non-stationary events are thought to arise due to airborne dust passing through the laser beam paths. We show that these non-stationary events which occur in our laboratory environment can be minimised by placing the experiment in an airtight enclosure. Isolation against non-stationary events achieved improvement of the colour of the noise spectrum by 3dB at 10Hz towards a flat shot noise spectrum and improvement in the noise distribution of the signal towards a Gaussian distribution.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.
Future interferometric gravitational wave detectors will make use of the coupling between shot noise and radiation pressure noise that produces a squeezed output for the quantum noise at the dark-port of the interferometer allowing these interferometers to operate with a sensitivity that exceeds the standard quantum limit at certain frequencies. The ability of the detector to take advantage of this squeezed output state depends in part on the readout system used. With the phase modulated laser input planned for these interferometers the quantum-noise limited sensitivity is slightly better when homodyne (rather than heterodyne) detection is used. We show that by modifying the laser input spectrum for these interferometers, readout with heterodyne detection can be made to have the same quantum-noise limited sensitivity as readout with homodyne detection.
Homodyne detection relies on the beat between a relatively strong local oscillator (LO) field at the carrier frequency and a signal beam with sidebands centered around the carrier frequency. This type of signal detection, or signal readout, is widely used in quantum optics applications and is expected to be used in advanced interferometric gravitational wave detectors. We investigate experimentally the limitations to making such measurements in a laboratory environment at audio frequencies. We find that beam jitter noise, electronic noise of the photodetectors, and the LO intensity noise can limit the homodyne detection in this frequency band, and we discuss potential solutions.
Wideband calculations of the response of a homodyne detector to the outputs of various four-wave-mixer configurations are presented. It is shown that the noise-power spectrum of the homodyne detector output can exhibit regions where the noise is greatly reduced below the shot-noise level even at frequencies far from dc. Hence, in the detection of noise squeezing via homodyne detectors, 1/f noise and other low-frequency noise sources may be avoided by observing the homodyne detector's noise power at frequencies far from dc.
Vacuum fluctuation at audio frequencies is very important and interesting in many research fields, such as the gravitational wave detection, ultra-weak magnetic field measurement, and the research of quantum metrology, etc. Since the generation of squeezed light in 1985, most of the squeezed light have been generated and measured at radio frequencies (~MHz) as there has not been much technical noise at higher frequencies. In the Michelson-interferometer-based gravitational wave detection, the detection band has frequencies from a few to tens of thousands Hz. Measuring vacuum noise at such low frequencies is a challenge since we have to stabilize and control all the audio noises and the interferences from a variety of mechanical and electronic noises, therefore a very high classical noise suppression is needed when the measurement time increases. In order to measure the squeezed light of low frequencies, the standard vacuum noise at audio frequencies must be measured. In this paper, a balanced homodyne detection system for measuring the low-frequency quantum vacuum noises is reported. It is not trivial to extend the detected frequency to very low analysis frequencies. Through a self-made self-subtraction balanced homodyne configuration, which can eliminate the DC component of each photocurrent from the photodiode and the classical common-mode technical noise, the standard vacuum noise has been detected. The linearity of the vacuum noise power has been validated by varying the local oscillator power, showing that the saturation power of light incidence is about 3.2 mW. When the incident-light power is 400 W, the standard vacuum noise is 11 dB higher than the electronic noise at 80 Hz. In the regime of about 80 Hz to 400 kHz, the linearity of the standard noise power as a function of incident laser power is verified. However, when the measurement is carried out at even lower frequencies, for example, 50 Hz, we may encounter some excess and non-stationary noises and find that the measured noise power is not proportional to the incident light power any more. These non-stationary noises are the main technical obstacle at low frequencies. The average common mode rejection ratio in the test frequency range from 10 Hz to 400 kHz is 55 dB and its maximum 63 dB at 100 Hz is obtained, implying a high suppression of the technical noise. This self-made homodyne vacuum noise detector can be widely used for precision measurement in quantum metrology and quantum optics.