Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Increase of Signal-to-Noise Ratio in Weak Value Measurements

Courtney L. Byard, Trent Graham, Ariel Danan, Lev Vaidman A, Andrew N. Jordan, Paul G. Kwiat

Published Sep 12, 2013• 2 citations
Publisher
DOI
10.1007/978-88-470-5217-8_26

Related papers

ON SIGNAL AMPLIFICATION FROM WEAK-VALUE AMPLIFICATION

Yutaka Shikano

•Apr 1, 2014•1 citation

Increasing the Signal-to-Noise Ratio in Weak-Value Measurements

Courtney L. Byard, Trent Graham, Ariel Danan +2 more

By recycling non-post selected photons through a Sagnac interferometer in our optical weak measurement of a mirror tilt, we double the detected intensity, resulting in a signal-to-noise ratio improvement of 1.57 over un-recycled experiments.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•0 citations

Optimal signal amplification by weak measurement

友紀 須佐, Yuki Susa

•Sep 1, 2012•0 citations

Enhanced Weak-Value Amplification via Photon Recycling

Courtney Krafczyk, Andrew N. Jordan, M. E. Goggin +1 more

In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.

arXiv:2104.14393•Physical Review Letters•Jun 1, 2021•40 citations

Weak-value-amplification analysis beyond the Aharonov-Albert-Vaidman limit

Jianhua Ren, Lupei Qin, Wei Feng +1 more

The weak-value (WV) measurement proposed by Aharonov, Albert, and Vaidman (AAV) has attracted a great deal of interest in connection with quantum metrology. In this paper, we extend the analysis beyond the AAV limit and obtain a few main results. (i) We obtain a nonperturbative result for the signal-to-noise ratio (SNR). In contrast to the AAV prediction, we find that the SNR asymptotically gets worse when the AAV WV ${A}_{w}$ becomes large, i.e., in the case $g|{A}_{w}{|}^{2}\ensuremath{\gg}1$, where $g$ is the measurement strength. (ii) With the increase of $g$ (but also small), we find that the SNR is comparable to the result under the AAV limit, while both can reach---actually the former can slightly exceed---the SNR of the standard measurement. However, with a further increase of $g$, the WV technique will become less efficient than the standard measurement, despite the fact that the postselection probability is increased. (iii) We find that the Fisher information can characterize the estimate precision qualitatively well as the SNR, yet the difference will become more prominent with the increase of $g$. (iv) We carry out analytic expressions of the SNR in the presence of technical noises and illustrate the particular advantage of the imaginary WV measurement. The nonperturbative result of the SNR manifests a favorable range of the noise strength and allows an optimal determination.

arXiv:2004.01108•Physical Review A•Oct 1, 2020•30 citations

The influence of non-Gaussian noise on weak values

Fangyuan Ma, Jungang Li, Jian Zou

Physics Letters A•Nov 19, 2020•4 citations
In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.
The weak-value (WV) measurement proposed by Aharonov, Albert, and Vaidman (AAV) has attracted a great deal of interest in connection with quantum metrology. In this paper, we extend the analysis beyond the AAV limit and obtain a few main results. (i) We obtain a nonperturbative result for the signal-to-noise ratio (SNR). In contrast to the AAV prediction, we find that the SNR asymptotically gets worse when the AAV WV Aw{A}_{w}Aw​ becomes large, i.e., in the case $g|{A}_{w}{|}^{2}\ensuremath{\gg}1$, where ggg is the measurement strength. (ii) With the increase of ggg (but also small), we find that the SNR is comparable to the result under the AAV limit, while both can reach---actually the former can slightly exceed---the SNR of the standard measurement. However, with a further increase of ggg, the WV technique will become less efficient than the standard measurement, despite the fact that the postselection probability is increased. (iii) We find that the Fisher information can characterize the estimate precision qualitatively well as the SNR, yet the difference will become more prominent with the increase of ggg. (iv) We carry out analytic expressions of the SNR in the presence of technical noises and illustrate the particular advantage of the imaginary WV measurement. The nonperturbative result of the SNR manifests a favorable range of the noise strength and allows an optimal determination.