Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2104.14393 · Physical Review Letters

Enhanced Weak-Value Amplification via Photon Recycling

Courtney Krafczyk, Andrew N. Jordan, M. E. Goggin, Paul G. Kwiat

Published Jun 1, 2021• 40 citations
arXivHTMLPDF

Abstract

In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.

DOI
10.1103/physrevlett.126.220801

Related papers

Dual-recycled interference-based weak value metrology

Zi-Rui Zhong, Weijun Tan, Yue Chen +1 more

Weak value amplification permits small effects to be measured as observable changes at the sacrifice of power due to postselection. The power-recycling scheme has been proven to eliminate this inefficiency of the rare postselection, thus surpassing the limit of the shot noise and improving the precision of the measurement. However, the improvement is strictly limited by the system setup, especially the system loss. Here we introduce a dual-recycling model based on the interferometric weak-value-based deflection measurement. Two mirrors, the power-recycling mirror and signal-recycling mirror, are placed at the bright and dark port of the interferometer, respectively, creating a composite resonator. The results show that both the power and the signal-to-noise ratio (SNR) are greatly enhanced in a wider range of experimental parameters compared to the power-recycling scheme. This work considerably loosens the constraint of the system setup and further explores the real advantage of weak measurement over traditional schemes.

arXiv:2309.06832•Physical Review A•Sep 18, 2023•8 citations

Increasing the Signal-to-Noise Ratio in Weak-Value Measurements

Courtney L. Byard, Trent Graham, Ariel Danan +2 more

By recycling non-post selected photons through a Sagnac interferometer in our optical weak measurement of a mirror tilt, we double the detected intensity, resulting in a signal-to-noise ratio improvement of 1.57 over un-recycled experiments.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•0 citations

Strengthening weak-value amplification with recycled photons

Justin Dressel, Kevin Lyons, Andrew N. Jordan +2 more

We consider the use of cyclic weak measurements to improve the sensitivity of weak-value amplification precision measurement schemes. Previous weak-value experiments have used only a small fraction of events, while discarding the rest through the process of ``postselection.'' We extend this idea by considering recycling of events which are typically unused in a weak measurement. Here we treat a sequence of polarized laser pulses effectively trapped inside an interferometer using a Pockels cell and polarization optics. In principle, all photons can be postselected, which will improve the measurement sensitivity. We first provide a qualitative argument for the expected improvements from recycling photons, followed by the exact result for the recycling of collimated beam pulses, and numerical calculations for diverging beams. We show that beam degradation effects can be mitigated via profile flipping or Zeno reshaping. The main advantage of such a recycling scheme is an effective power increase, while maintaining an amplified deflection.

arXiv:1305.4520•Physical Review A•Aug 13, 2013•72 citations

Signal-recycled weak measurement for ultrasensitive velocity estimation*

Sen-Zhi Fang, Yang Dai, Qian-Wen Jiang +3 more

Weak value amplification has shown its superiority in measurement of small physical effects. Here we introduce a signal-recycled weak-value-based velocity measurement strategy to decrease the attenuation of detected photons during the post-selection. Like the power-recycled scheme, we can improve the number of detected photons and signal-to-noise ratio of velocity by forming a cavity. However, optimal improvements of number of detected photons and signal-to-noise ratio cannot be obtained simultaneously in our signal-recycled scheme owing to the walk-off effect. Furthermore, we find that the reflected light is relatively strong compared with the power-recycled scheme, which may increase the collection-detection efficiency in prospective relevant experiment.

Chinese Physics B•Jan 13, 2021•4 citations

Weak Value Measurements with Pulse Recycling

Courtney Krafczyk, Trent Graham, Andrew N. Jordan +1 more

Recycling undetected photons in a weak measurement can substantially improve the signal-to-noise ratio. We demonstrate a preliminary improvement by a factor of 1.36 over a system with no recycling, potentially reaching a factor of 3.2.

Frontiers in Optics•Jan 1, 2016•0 citations

Power-Recycled Weak-Value-Based Metrology

Kevin Lyons, Justin Dressel, Andrew N. Jordan +2 more

We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in all the light exiting to the detector with a large deflection, thus eliminating the inefficiency of the rare postselection. The signal-to-noise ratio of the deflection is itself magnified by the weak value. We discuss ways to realize this proposal, using a transverse beam filter and different cavity designs.

arXiv:1504.08210•Physical Review Letters•Apr 29, 2015•70 citations
In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.
Weak value amplification permits small effects to be measured as observable changes at the sacrifice of power due to postselection. The power-recycling scheme has been proven to eliminate this inefficiency of the rare postselection, thus surpassing the limit of the shot noise and improving the precision of the measurement. However, the improvement is strictly limited by the system setup, especially the system loss. Here we introduce a dual-recycling model based on the interferometric weak-value-based deflection measurement. Two mirrors, the power-recycling mirror and signal-recycling mirror, are placed at the bright and dark port of the interferometer, respectively, creating a composite resonator. The results show that both the power and the signal-to-noise ratio (SNR) are greatly enhanced in a wider range of experimental parameters compared to the power-recycling scheme. This work considerably loosens the constraint of the system setup and further explores the real advantage of weak measurement over traditional schemes.
We consider the use of cyclic weak measurements to improve the sensitivity of weak-value amplification precision measurement schemes. Previous weak-value experiments have used only a small fraction of events, while discarding the rest through the process of ``postselection.'' We extend this idea by considering recycling of events which are typically unused in a weak measurement. Here we treat a sequence of polarized laser pulses effectively trapped inside an interferometer using a Pockels cell and polarization optics. In principle, all photons can be postselected, which will improve the measurement sensitivity. We first provide a qualitative argument for the expected improvements from recycling photons, followed by the exact result for the recycling of collimated beam pulses, and numerical calculations for diverging beams. We show that beam degradation effects can be mitigated via profile flipping or Zeno reshaping. The main advantage of such a recycling scheme is an effective power increase, while maintaining an amplified deflection.
Weak value amplification has shown its superiority in measurement of small physical effects. Here we introduce a signal-recycled weak-value-based velocity measurement strategy to decrease the attenuation of detected photons during the post-selection. Like the power-recycled scheme, we can improve the number of detected photons and signal-to-noise ratio of velocity by forming a cavity. However, optimal improvements of number of detected photons and signal-to-noise ratio cannot be obtained simultaneously in our signal-recycled scheme owing to the walk-off effect. Furthermore, we find that the reflected light is relatively strong compared with the power-recycled scheme, which may increase the collection-detection efficiency in prospective relevant experiment.