Japanese Journal of Applied Physics

Experimental Demonstration and Numerical Analysis of Microampere Gray Zone Width with Enhanced Operating Margin in Shunted Quasi-One Junction Superconducting Quantum Interference Device Comparators

Shigeyuki Miyajima, Thomas Ortlepp, Hannes Toepfer, Ali Bozbey, Akira Fujimaki

Published Feb 25, 2013• 6 citations
Publisher

Abstract

We evaluated the relationship between the gray zone width and the operating margin for comparators composed of quasi-one-junction superconducting quantum interference devices (QOSs) with shunt resistors, which are often used as high-speed readout circuits in multiple superconductor detector systems. The gray zone width is a good measure of current sensitivity of a single-bit comparator. We numerically analyzed the gray zone width of a QOS comparator and determined the circuit parameters. The gray zone width obtained from the experiments concurred with the results of the numerical analysis and was 2–3 µA at 4.2 K in a QOS comparator composed of three Nb/AlOx/Nb junctions with critical currents of less than 90 µA. The experimentally obtained operating margin for the bias current provided to the comparator was ±15% at the bias current of around 140 µA. These results show that QOS comparators are promising for readout circuits operating up to tens of GHz and imply that gray zone width is the thermal noise in the resistors at 4.2 K.

DOI
10.7567/jjap.52.033101

Related papers

Unshunted QOS Comparator for Qubit Readout

Thomas Ohki, Michael Wulf, M. J. Feldman +1 more

State measurements of flux-based superconducting quantum bits (qubits) require the sensitive discrimination of small differences of magnetic flux, with measurement times short compared to the timescales of coherent quantum mechanical behaviour. The single-flux-quantum (SFQ) superconducting comparator may be the best device for this purpose. An SFQ comparator design using a quasi-one-junction SQUID (QOS) acting as the comparator junction has two advantages over earlier designs—increased sensitivity and the possibility to eliminate shunt resistors. Here we report the first measurements of the sensitivity of an unshunted QOS comparator. The gray zone of this device at 4.2K is 6 mΦo.

Journal of Physics Conference Series•Jun 1, 2006•7 citations

Balanced Comparator for RSFQ Qubit Readout

Thomas Ohki, Alexander M. Savin, Juha Hassel +3 more

The balanced comparator is an essential part of RSFQ-based readout for superconducting qubits. In this paper we report measurements of the sensitivity of the balanced comparator fabricated in a specialized 30 A/cm2process with 3.6 muA critical currents and measured at 30-500 mK. At sampling frequency of 3.5 GHz the measured gray zone is DeltaI = 104 nA. Due to electron overheating in the shunt resistors the effective noise temperature is 140 mK. The gray zone has a strong dependence on sampling frequency above 5 GHz due to over-clocking. Related measurements have been reported where cooling fins and reduced critical current density of 10 A/cm2were used, and a quantum limited gray zone of 40 nA was achieved. This makes single shot readout possible for the phase, RF-SQUID and persistent current qubits. The readout speed is 30-50 ps, which is quite favorable for error correction schemes.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•9 citations

Evaluation of current sensitivity of quantum flux parametron

Yuki Yamanashi, Takashi Matsushima, Naoki Takeuchi +2 more

Abstract Current sensitivity of a quantum flux parametron (QFP) was evaluated by measuring gray zone width on the basis of both circuit simulation and measurements, for superconducting sensing systems composed of a superconducting sensor array and superconducting read-out and signal processing circuits. Simulation results indicate a narrow gray zone width can be obtained by decreasing inductances comprising the QFP. Moreover, both high-sensitivity and low-power operation of the QFP can be realized by using optimized circuit parameters with an excitation current that has long rise time. A gray zone width of approximately 0.5 μ A, which is smaller than that of the Josephson current comparator based on a single flux quantum circuit, was obtained experimentally, using a trapezoidal excitation current with rise time of 50 μ s. These results indicate the QFP is promising for the read-out circuit in superconducting sensing systems, due to its high sensitivity and low power consumption.

Superconductor Science and Technology•Jul 4, 2017•14 citations

Experimental Analysis of the Bias Dependent Sensitivity of a Josephson Comparator

Taghrid Haddad, Sonja Engert, Oliver Brandel +4 more

The Josephson comparator is one of the building blocks of superconductor electronics. It is used as a decision element in all analog and digital circuits. For fast high-bandwidth analog-to-digital converters as well as for digital circuits with reduced switching energy its high sensitivity is most important. Thermal noise limits its decision uncertainty. In this work we analyze the influence of the bias current on the gray zone of a Josephson comparator. Circuit simulations are compared against experimental data. The experimental analysis shows a characteristic dependence of the gray zone on the bias current. We can identify a clear minimum value. This point is related to a certain clock frequency. At low frequencies the simulated relationship between the gray zone and the bias current is in very good agreement with experimental results. The comparison confirmed the circuit model and enables to adjust the design to certain applications to realize the best trade-off between clock frequency and grey zone. The article describes the experimental validation procedure and a derived normalized dependency in detail.

IEEE Transactions on Applied Superconductivity•Jan 19, 2015•2 citations

High-speed operation of quasi-one junction superconducting quantum interference device based on high-Tc multilayer technology

H. Sugiyama, H. Wakana, Seiji Adachi +2 more

We designed a quasi-one junction superconducting quantum interference device (QOS) based on single-flux-quantum technology using high-Tc superconductors. A circuit containing 10 interface-engineered ramp-edge Josephson junctions was fabricated on a La-substituted YBa2Cu3Oy ground plane. The output voltage as a function of the input current for the QOS indicated correct operation as a periodic comparator at clock frequency of 94 and 77 GHz at 35 and 40 K, respectively. A comparison of the observed maximum operating frequency with the product of the critical current and normal resistance for the junctions suggests that comparator operation above 100 GHz at 40 K is possible if one optimizes the junction parameters.

Applied Physics Letters•Apr 1, 2004•14 citations

Investigation of the relationship between the gray zone and the clock frequency of a Josephson comparator

Taghrid Haddad, Olaf Wetzstein, Sonja Engert +2 more

The Josephson comparator is one of the fundamental building blocks of rapid single flux quantum (RSFQ) electronics. Within this circuit family it is the exclusive device which provides logical data processing. The Josephson comparator is also the basic decision element for very fast analog-to-digital converters and sampler circuits for low input power and high-bandwidth signals based on the RSFQ technique. The performance of those devices is fundamentally determined by the characteristics of the Josephson comparator. In this study the gray zone dependency on the clock frequency of a Josephson comparator is investigated by simulations concerning the influence of thermal noise. This investigation is performed for a series of operating points defined by the bias current and different noise levels defined by the operating temperature. In contrast to former investigations, we analyzed the comparator embedded in a realistic environment for output data processing. We identified a characteristic clock frequency f c for a comparator topology designed for a 1 kA cm − 2 niobium fabrication technology. The gray zone of 8 µA remains constant for clock frequencies below f c = 15 GHz and starts to increase for larger frequencies. We also found out that this characteristic frequency is independent of the intensity of thermal noise and therefore independent of temperature.

Superconductor Science and Technology•Aug 5, 2011•15 citations
We evaluated the relationship between the gray zone width and the operating margin for comparators composed of quasi-one-junction superconducting quantum interference devices (QOSs) with shunt resistors, which are often used as high-speed readout circuits in multiple superconductor detector systems. The gray zone width is a good measure of current sensitivity of a single-bit comparator. We numerically analyzed the gray zone width of a QOS comparator and determined the circuit parameters. The gray zone width obtained from the experiments concurred with the results of the numerical analysis and was 2–3 µA at 4.2 K in a QOS comparator composed of three Nb/AlOx/Nb junctions with critical currents of less than 90 µA. The experimentally obtained operating margin for the bias current provided to the comparator was ±15% at the bias current of around 140 µA. These results show that QOS comparators are promising for readout circuits operating up to tens of GHz and imply that gray zone width is the thermal noise in the resistors at 4.2 K.
State measurements of flux-based superconducting quantum bits (qubits) require the sensitive discrimination of small differences of magnetic flux, with measurement times short compared to the timescales of coherent quantum mechanical behaviour. The single-flux-quantum (SFQ) superconducting comparator may be the best device for this purpose. An SFQ comparator design using a quasi-one-junction SQUID (QOS) acting as the comparator junction has two advantages over earlier designs—increased sensitivity and the possibility to eliminate shunt resistors. Here we report the first measurements of the sensitivity of an unshunted QOS comparator. The gray zone of this device at 4.2K is 6 mΦo.
The balanced comparator is an essential part of RSFQ-based readout for superconducting qubits. In this paper we report measurements of the sensitivity of the balanced comparator fabricated in a specialized 30 A/cm2process with 3.6 muA critical currents and measured at 30-500 mK. At sampling frequency of 3.5 GHz the measured gray zone is DeltaI = 104 nA. Due to electron overheating in the shunt resistors the effective noise temperature is 140 mK. The gray zone has a strong dependence on sampling frequency above 5 GHz due to over-clocking. Related measurements have been reported where cooling fins and reduced critical current density of 10 A/cm2were used, and a quantum limited gray zone of 40 nA was achieved. This makes single shot readout possible for the phase, RF-SQUID and persistent current qubits. The readout speed is 30-50 ps, which is quite favorable for error correction schemes.
Abstract Current sensitivity of a quantum flux parametron (QFP) was evaluated by measuring gray zone width on the basis of both circuit simulation and measurements, for superconducting sensing systems composed of a superconducting sensor array and superconducting read-out and signal processing circuits. Simulation results indicate a narrow gray zone width can be obtained by decreasing inductances comprising the QFP. Moreover, both high-sensitivity and low-power operation of the QFP can be realized by using optimized circuit parameters with an excitation current that has long rise time. A gray zone width of approximately 0.5 μ A, which is smaller than that of the Josephson current comparator based on a single flux quantum circuit, was obtained experimentally, using a trapezoidal excitation current with rise time of 50 μ s. These results indicate the QFP is promising for the read-out circuit in superconducting sensing systems, due to its high sensitivity and low power consumption.
The Josephson comparator is one of the building blocks of superconductor electronics. It is used as a decision element in all analog and digital circuits. For fast high-bandwidth analog-to-digital converters as well as for digital circuits with reduced switching energy its high sensitivity is most important. Thermal noise limits its decision uncertainty. In this work we analyze the influence of the bias current on the gray zone of a Josephson comparator. Circuit simulations are compared against experimental data. The experimental analysis shows a characteristic dependence of the gray zone on the bias current. We can identify a clear minimum value. This point is related to a certain clock frequency. At low frequencies the simulated relationship between the gray zone and the bias current is in very good agreement with experimental results. The comparison confirmed the circuit model and enables to adjust the design to certain applications to realize the best trade-off between clock frequency and grey zone. The article describes the experimental validation procedure and a derived normalized dependency in detail.
We designed a quasi-one junction superconducting quantum interference device (QOS) based on single-flux-quantum technology using high-Tc superconductors. A circuit containing 10 interface-engineered ramp-edge Josephson junctions was fabricated on a La-substituted YBa2Cu3Oy ground plane. The output voltage as a function of the input current for the QOS indicated correct operation as a periodic comparator at clock frequency of 94 and 77 GHz at 35 and 40 K, respectively. A comparison of the observed maximum operating frequency with the product of the critical current and normal resistance for the junctions suggests that comparator operation above 100 GHz at 40 K is possible if one optimizes the junction parameters.
The Josephson comparator is one of the fundamental building blocks of rapid single flux quantum (RSFQ) electronics. Within this circuit family it is the exclusive device which provides logical data processing. The Josephson comparator is also the basic decision element for very fast analog-to-digital converters and sampler circuits for low input power and high-bandwidth signals based on the RSFQ technique. The performance of those devices is fundamentally determined by the characteristics of the Josephson comparator. In this study the gray zone dependency on the clock frequency of a Josephson comparator is investigated by simulations concerning the influence of thermal noise. This investigation is performed for a series of operating points defined by the bias current and different noise levels defined by the operating temperature. In contrast to former investigations, we analyzed the comparator embedded in a realistic environment for output data processing. We identified a characteristic clock frequency f c for a comparator topology designed for a 1 kA cm − 2 niobium fabrication technology. The gray zone of 8 µA remains constant for clock frequencies below f c = 15 GHz and starts to increase for larger frequencies. We also found out that this characteristic frequency is independent of the intensity of thermal noise and therefore independent of temperature.