Optics Communications

Improved three-dimensional control of a single strontium ion in an endcap trap

Alastair G. Sinclair, M.A. Wilson, Patrick Robert Gill

Published Apr 1, 2001• 39 citations
Publisher
DOI
10.1016/s0030-4018(01)01057-4

Related papers

Simulation and Optimization of Miniature Ring-Endcap Ion Traps

Cao, Jian JIAN, Tong +9 more

Chinese Physics Letters•Jan 1, 2014•1 citation

Laser Ablation Loading and Single Ion Addressing of Strontium in a Linear Paul Trap

Andreas Pöschl

•Jan 1, 2018•0 citations

Optimization of endcap trap for single-ion manipulation

Yuan Qian, Chang-Da-Ren Fang, Yao Huang +2 more

Potential distribution is an important characteristic for evaluating the performance of an ion trap. Here, we analyze and optimize the potential distribution of an endcap ion trap for single-ion trapping. We obtain an optimal endcap radius of 225 μm–250 μm, endcap-shield gap of ∼ 250 μm, and inter-endcap distance of 540 μm–590 μm. The simulation method for analysis can also be applied to other ion traps, which is useful for improving the design and assembly of ion traps.

Chinese Physics B•Jun 1, 2018•2 citations

Progress towards isotope-dependent trapping of strontium

Roger Ding, Francisco Camargo, J. D. Whalen +3 more

Bulletin of the American Physical Society•May 25, 2016•0 citations

Simulation and Optimization of Miniature Ring-Endcap Ion Traps

Jian Cao, Xin Tong, Kaifeng Cui +3 more

With the decrease in dimension of ion traps employed in optical frequency standards and precision spectroscopy, the sensitivity of trapping behavior to trap geometry is more and more prominent. We present a guide for the design and construction of a miniature trap for a single ion confinement, and propose an optimized combination of r ring /r endcap ≈ 0.5 and z 0 ≈ r 0 within the range of r 0 = 0.7 ± 0.2 mm. Compared with the trap used by Huang et al. [ Phys. Rev. A 84 (2011) 053841 ], the design can lead to an increase in trap pseudo-potential of more than 20% and a reduction on potential anharmonicity of more than 90%. The improvements make the trap closer to an ideal hyperboloidal trap to confine a single ion tightly with the benefit of weaker micro-motion. Considering the imperfection of electrodes machining and traps alignment, we also demonstrate the importance of trap symmetry, especially on two endcap electrodes.

Chinese Physics Letters•Apr 1, 2014•3 citations

Recent progress on the NRC 88Sr+ single-ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +4 more

We report our recent progress made with the NRC88Sr+single-ion optical frequency standard. The long-term operation of the standard was improved by actively stabilizing the cooling, repump and clearout laser sources, and by using a femtosecond fiber laser frequency comb to link the probe laser frequency to the microwave time standards. With the femtosecond fiber comb, we have demonstrated continuous operation for a period of eight days and continuous measurement of the probe laser source for three days. Micromotion shifts have been the dominant source of uncertainty in our rf Paul trap because laser beam access is only possible along one axis in the current design. With the aim of reducing to a minimum these shifts, we have constructed an endcap trap designed for minimization of micromotion along three orthogonal axes. We report on the successful trapping of single ions with this endcap trap. Since electrode contamination during trap loading can also induce micromotion shifts as a result of evolving patch potentials, we have increased the trap loading efficiency with photo-ionization.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2010•2 citations
With the decrease in dimension of ion traps employed in optical frequency standards and precision spectroscopy, the sensitivity of trapping behavior to trap geometry is more and more prominent. We present a guide for the design and construction of a miniature trap for a single ion confinement, and propose an optimized combination of r ring /r endcap ≈ 0.5 and z 0 ≈ r 0 within the range of r 0 = 0.7 ± 0.2 mm. Compared with the trap used by Huang et al. [ Phys. Rev. A 84 (2011) 053841 ], the design can lead to an increase in trap pseudo-potential of more than 20% and a reduction on potential anharmonicity of more than 90%. The improvements make the trap closer to an ideal hyperboloidal trap to confine a single ion tightly with the benefit of weaker micro-motion. Considering the imperfection of electrodes machining and traps alignment, we also demonstrate the importance of trap symmetry, especially on two endcap electrodes.
We report our recent progress made with the NRC88Sr+single-ion optical frequency standard. The long-term operation of the standard was improved by actively stabilizing the cooling, repump and clearout laser sources, and by using a femtosecond fiber laser frequency comb to link the probe laser frequency to the microwave time standards. With the femtosecond fiber comb, we have demonstrated continuous operation for a period of eight days and continuous measurement of the probe laser source for three days. Micromotion shifts have been the dominant source of uncertainty in our rf Paul trap because laser beam access is only possible along one axis in the current design. With the aim of reducing to a minimum these shifts, we have constructed an endcap trap designed for minimization of micromotion along three orthogonal axes. We report on the successful trapping of single ions with this endcap trap. Since electrode contamination during trap loading can also induce micromotion shifts as a result of evolving patch potentials, we have increased the trap loading efficiency with photo-ionization.