Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser Ablation Loading and Single Ion Addressing of Strontium in a Linear Paul Trap

Andreas Pöschl

Published Jan 1, 2018• 0 citations
OpenAlex

Related papers

Buffer gas loading and Doppler cooling of strontium ions in a planar Paul trap

Robert Clark, Kenneth R. Brown, Jaroslaw Labaziewicz +2 more

Bulletin of the American Physical Society•May 19, 2006•0 citations

surface-electrode ion trap loaded by laser ablation

Paul Antohi, Waseem Bakr, Isaac L. Chuang +2 more

Bulletin of the American Physical Society•Mar 6, 2007•0 citations

Isotope-selective Laser Ablation Loading of Trapped Barium Ions

Pei Jiang Low, Brendan Bramman, Matthew Day +1 more

Bulletin of the American Physical Society•Jun 2, 2021•0 citations

Laser ablation loading of Yb+++ ions in a surface trap

Yuhi Aikyo, Geert Vrijsen, Robert Spivey +2 more

Bulletin of the American Physical Society•May 31, 2018•0 citations

Loading of large ion Coulomb crystals into a linear Paul trap incorporating an optical cavity

Peter F. Herskind, Aurélien Dantan, M. B. Langkilde-Lauesen +3 more

arXiv:0804.4589•Applied Physics B•Sep 12, 2008•37 citations

Dynamic laser ablation loading of a linear Paul trap

Lin Li, Zi Li, Xia Hua +1 more

Abstract We present a detailed method for accumulating Ca+ ions controllably in a linear Paul trap. The ions are generated by pulsed laser ablation and dynamically loaded into the ion trap by switching the trapping potential on and off. The loaded ions are precooled by buffer gas and then laser-cooled to form Coulomb crystals for verifying quantity. The number of ions is controlled by manipulating the trapping potential of the ion trap, partial pressure of buffer gas and turn-on time of the entrance end cap voltage. With single-pulse laser ablation, the number of trapped ions ranges from tens to ten thousand. The kinetic energy of loaded ions can be selected via the optimal turn-on time of the entrance end cap. Using multiple-pulse laser ablation, the number is further increased and reaches about 4 × 10 4 . The dynamic loading method has wide application for accumulating low-yielding ions via laser ablation in the ion trap.

arXiv:2402.17981•Journal of Physics D Applied Physics•Apr 29, 2024•7 citations
Abstract We present a detailed method for accumulating Ca+ ions controllably in a linear Paul trap. The ions are generated by pulsed laser ablation and dynamically loaded into the ion trap by switching the trapping potential on and off. The loaded ions are precooled by buffer gas and then laser-cooled to form Coulomb crystals for verifying quantity. The number of ions is controlled by manipulating the trapping potential of the ion trap, partial pressure of buffer gas and turn-on time of the entrance end cap voltage. With single-pulse laser ablation, the number of trapped ions ranges from tens to ten thousand. The kinetic energy of loaded ions can be selected via the optimal turn-on time of the entrance end cap. Using multiple-pulse laser ablation, the number is further increased and reaches about 4 × 10 4 . The dynamic loading method has wide application for accumulating low-yielding ions via laser ablation in the ion trap.