We present a design for a spin-exchange optical pumping system to produce large quantities of highly polarized 129Xe. Low xenon concentrations in the flowing gas mixture allow the laser to maintain high Rb polarization. The large spin-exchange rate between Rb and 129Xe through the long-lived van der Waals molecules at low pressure, combined with a high flow rate, results in large production rates of hyperpolarized xenon. We report a maximum polarization of 64% achieved for a 0.3 l/h Xe flow rate, and maximum magnetization output of 6 l/h at 22% polarization. Our findings regarding the polarization dependence on temperature, nitrogen partial pressure, and gas mixture flow velocity are also reported.
We present a design for a spin-exchange optical pumping system to produce large quantities of highly polarized 129Xe and 131Xe. Low xenon concentrations in the flowing gas mixture which allow the laser to maintain high Cs polarization. The large spin-exchange rate between Cs and Xe through the long-lived van der Waals molecules at low pressure, combined with a high flow rate, results in large production rates of hyperpolarized xenon. The fast rates make it possible to obtain large nuclear polarizations after several minutes of optical pumping with a laser.At high Xe pressures. According to the theory, the longitudinal spin-elaxation rate 1T1 of Xe in a high-pressure sample containing only Xe and Cs vapor has the simple form is the velocity averaged binary spin-exchange cross section, It is the relaxation rate due to wall collisions and perhaps magnetic field inhomogeneities. Our results complement earlier studies performed at 129Xe pressures of about 20 Torr and 131Xe pressures of about 20 Torr and N2 pressures of 600 Torr . This work is useful for predicting spin-exchange rates between polarized Cs atoms and Xe nuclei.
Here we present a $\mathrm{Rb}\text{\ensuremath{-}}^{129}\mathrm{Xe}$ spin-exchange optical pumping polarizer capable of rapid generation of large volumes of highly polarized
129Xe gas. Through modeling and measurements we maximize the
129Xe nuclear spin polarization output to enable the generation of polarized
129Xe gas imaging volumes (
300 cm3) every 5 min within a clinical setting. Our model is verified by experiment to correctly predict the optimum Rb vapor density for maximum
129Xe nuclear polarization for a flux
3.4 W/cm2 of circularly polarized Rb
D1 photons incident on an 80 cm long cylindrical optical cell. We measure a
129Xe magnetization production efficiency of ${\ensuremath{\eta}}_{\mathrm{pr}}=1.8%$, which approaches the photon efficiency limit ${\ensuremath{\eta}}_{\ensuremath{\gamma}}=3.3%$ of this system and enables the polarization of $2.72\ifmmode\times\else\texttimes\fi{}{10}^{22}$
129Xe spins per hour, corresponding to
1013 cm3 of 100% polarized
129Xe at STP. This magnetization production rate is threefold higher than the highest previously published
129Xe magnetization production rate and has enabled routine clinical lung magnetic resonance imaging (MRI) with hyperpolarized
129Xe doses available on demand at run time, as well as high-SNR
129Xe MRI of the human brain and kidneys.
Hyperpolarized
129Xe finds numerous applications in NMR spectroscopy and magnetic resonance imaging. The production of hyperpolarized
129Xe by spin-exchange optical pumping is therefore an important experimental issue. We model the three-dimensional transport processes within a so-called batch mode pump cell via numerical finite element method simulations and compare the results with experimental data. In particular, the influence of different experimental parameters, such as temperature, xenon and nitrogen partial pressure, laser power, and radius-to-length ratio of a cylindrical pump cell, is evaluated. The developed numerical method is capable of describing the spin-exchange optical pumping process in a realistic manner.
The method to produce spin-polarized xenon-129 gas was based on the method of spin-exchange optical pumping (SEOP). The magnetizations produced by the hyperpolarized (HP) xenon-129 gas were analyzed from the perspective of theoretical and experimental research. The theoretical simulation was based on the conventional Bloch equation. The experimental research was based on measurements made by using an all-optical atomic magnetometer. The experimental results agreed with the theoretical simulated results, which proved that an all-optical atomic magnetometer had the ability to measure the magnetic field produced by xenon-129 nuclei in a low external magnetic field. Because the frequency of the nuclear spin precession could be detected precisely, the results showed that the mean measurement error of the gyromagnetic ratio was 1.1 × 10 -4 Hz/nT.
We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.