Optics Letters

Squeezed light from second-harmonic generation: experiment versus theory

Timothy C. Ralph, Matthew S. Taubman, Andrew G. White, David E. McClelland, Hans‐A. Bachor

Published Jun 1, 1995• 33 citations
Publisher

Abstract

We report excellent quantitative agreement between theoretical predictions and experimental observation of squeezing from a singly resonant second-harmonic-generating crystal. Limitations in the noise suppression imposed by the pump laser are explicitly modeled and confirmed by our measurements.
DOI
10.1364/ol.20.001316

Related papers

Active versus passive squeezing by second-harmonic generation

Andrew G. White, Timothy C. Ralph, Hans‐A. Bachor

The characteristics of squeezed light generated by both passive (occurring in a cavity external to a laser) and active (occurring within a laser cavity) second-harmonic generation (SHG) are investigated and contrasted. Squeezing of both the fundamental and the second harmonic is discussed, and the issue of doubly versus singly resonant behavior is addressed. We examine passive squeezing by explicitly modeling the intrinsically noisy output of the pump laser and coupling it to a passive, multiport, lossy SHG cavity. Low-frequency degradation of the squeezing caused by the laser pump noise is predicted and provides a probable explanation for previous discrepancies between theory and experiment. Active squeezing is quantitatively modeled by a three-level laser model that retains all laser dynamics. Previously disparate predictions are reconciled. For one parameter set two regimes of squeezing are predicted: 50% squeezing at frequencies lower than the laser relaxation oscillation, and near-perfect squeezing at frequencies above. A particular problem of active squeezing is highlighted: The fast dephasing of the laser coherence introduces considerable excess noise likely to mask squeezing in experimental situations. We conclude that, although passive SHG is a practical source of squeezing, active SHG is unlikely to be so in the foreseeable future.

Journal of the Optical Society of America B•Jul 1, 1996•18 citations

Squeezed states in second-harmonic generation

L. A. Lugiato, F. De Martini, G. Strini

We consider the process of second-harmonic generation with the nonlinear crystal placed in a resonant cavity. Both the fundamental and the second-harmonic mode are shown to exhibit squeezing. An analysis is made for the general values of the ratio between the damping constants of the two modes. We suggest that second-harmonic generation is the most suitable system to use for an experimental observation of the squeezing effect.

Optics Letters•May 1, 1983•71 citations

Bright squeezing by singly resonant second-harmonic generation: effect of fundamental depletion and feedback

Joji Maeda, Kazuro Kikuchi

We analyze the squeezing characteristics of a singly resonant second-harmonic-generation system, in which only the fundamental light is confined in a plain cavity resonator, with consideration for fundamental depletion in a nonlinear crystal. The system was analyzed under the mean-field approximation, which neglects the variation of the field in the crystal, and as much as 9.5 dB of squeezing was predicted in the second-harmonic output. On the basis of the self-consistent method, we analyze the system, which is driven by such an intense fundamental input that the mean-field approximation is not valid, and predict that an arbitrary amount of squeezing will be available in this regime.

Optics Letters•Jun 1, 1996•11 citations

Generation of squeezed light via second harmonic generation

P. Nee

Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1994.

•Jan 1, 1994•0 citations

Green bright squeezed light from a cw periodically poled KTP second harmonic generator

Ulrik L. Andersen, Preben Buchhave

We present the experimental observation of bright amplitude squeezed light from a singly resonant second harmonic generator (SHG) based on a periodically poled potassium titanyl phosphate (KTP) crystal. Contrary to conventional SHG, the interacting waves in this device couple efficiently using quasi phase matching (QPM) and more importantly QPM allows access to higher valued elements of the nonlinear tensor than is possible under the constraint of birefringence phase matching. We observe a noise reduction of 13% below the shot noise limit in the generated second harmonic field. This noise reduction is greater than what could be expected using normal birefringence phase matched KTP with the same experimental parameters. Excellent agreement between experiment and theory is found.

Optics Express•Aug 26, 2002•12 citations

Squeezed states in harmonic generation of a laser beam

M. Kozierowski, S. Kielich

Physics Letters A•Mar 1, 1983•42 citations
The characteristics of squeezed light generated by both passive (occurring in a cavity external to a laser) and active (occurring within a laser cavity) second-harmonic generation (SHG) are investigated and contrasted. Squeezing of both the fundamental and the second harmonic is discussed, and the issue of doubly versus singly resonant behavior is addressed. We examine passive squeezing by explicitly modeling the intrinsically noisy output of the pump laser and coupling it to a passive, multiport, lossy SHG cavity. Low-frequency degradation of the squeezing caused by the laser pump noise is predicted and provides a probable explanation for previous discrepancies between theory and experiment. Active squeezing is quantitatively modeled by a three-level laser model that retains all laser dynamics. Previously disparate predictions are reconciled. For one parameter set two regimes of squeezing are predicted: 50% squeezing at frequencies lower than the laser relaxation oscillation, and near-perfect squeezing at frequencies above. A particular problem of active squeezing is highlighted: The fast dephasing of the laser coherence introduces considerable excess noise likely to mask squeezing in experimental situations. We conclude that, although passive SHG is a practical source of squeezing, active SHG is unlikely to be so in the foreseeable future.
We analyze the squeezing characteristics of a singly resonant second-harmonic-generation system, in which only the fundamental light is confined in a plain cavity resonator, with consideration for fundamental depletion in a nonlinear crystal. The system was analyzed under the mean-field approximation, which neglects the variation of the field in the crystal, and as much as 9.5 dB of squeezing was predicted in the second-harmonic output. On the basis of the self-consistent method, we analyze the system, which is driven by such an intense fundamental input that the mean-field approximation is not valid, and predict that an arbitrary amount of squeezing will be available in this regime.
We present the experimental observation of bright amplitude squeezed light from a singly resonant second harmonic generator (SHG) based on a periodically poled potassium titanyl phosphate (KTP) crystal. Contrary to conventional SHG, the interacting waves in this device couple efficiently using quasi phase matching (QPM) and more importantly QPM allows access to higher valued elements of the nonlinear tensor than is possible under the constraint of birefringence phase matching. We observe a noise reduction of 13% below the shot noise limit in the generated second harmonic field. This noise reduction is greater than what could be expected using normal birefringence phase matched KTP with the same experimental parameters. Excellent agreement between experiment and theory is found.