Applied Optics

Principles of Operation of the Rubidium Vapor Magnetometer

Arnold L. Bloom

Published Jan 1, 1962• 282 citations
Publisher

Abstract

This paper discusses some of the basic problems involved in designing and using a magnetometer employing optical pumping. Particular attention is given to magnetometers of the self-oscillating type; i.e., those that are analogous to masers in that the resonant properties of the spin system itself are used to sustain continuous oscillation at the resonant frequency. Among the topics treated are amplitude variations with orientation, sensitivity, behavior in extremely weak magnetic fields, and response to rapid field changes.

DOI
10.1364/ao.1.000061

Related papers

Rubidium vapour magnetometer

L W Parsons, Z M Wiatr

A rubidium vapour magnetometer has been made which measures the total geomagnetic field and records its variations continuously over the frequency band 0-1 c/s with sensitivity of 5 × 10 -6 Oe. Optical pumping technique is used to observe the energy separation between the Zeeman sub-levels in the ground state of 85 Rb atom, which is the measure of the ambient magnetic field and is equal to 220 kc/s for the local field of 472 × 10 -3 Oe, with the line width of 200 c/s. Resonance is detected when an applied r.f. field at the Larmor frequency causes redistribution of the population of the energy levels thus increasing absorption in the gas cell of the pumping radiation at 7948 Å. A voltage controlled oscillator supplying the r.f. field is locked on to the Larmor frequency. Resonance radiation is obtained from a rubidium lamp excited from a 150 Mc/s, 2 w power supply. The gas cell contains natural rubidium. This is kept at a temperature of 35-45° C thus maintaining vapour pressure of about 10 -6 mmHg. The design of the lamp and the gas cell is given. Further work to improve the light source and the gas cell should improve the sensitivity of the instrument. Redesign of the electronics to make the system oscillate at the Larmor frequency may also improve sensitivity and increase the frequency response of the instrument. The instrument described was demonstrated at The Institute of Physics and The Physical Society Exhibition in January 1961.

Journal of Scientific Instruments•Jun 1, 1962•29 citations

Remote detection magnetometry

Simon Rochester, James Higbie, Bob J. Patton +3 more

Introduction Shortly after the inception of atomic magnetometry, alkali-vapor magnetometers were being used to measure the Earth's magnetic field to unprecedented precision. During the same era, Bell and Bloom first demonstrated all-optical atomic magnetometry through synchronous optical pumping [1] (see Chapters 1 and 6). In this approach, optical-pumping light is frequency- or amplitude-modulated at harmonics of the Larmor frequency ω L to generate a precessing spin polarization within an alkali vapor at finite magnetic field [2, 3]. Although this technique received considerable attention from the atomic physics community for its applicability to optical pumping experiments, Earth's-field alkali-vapor atomic magnetometers continued to rely on radiofrequency (RF) field excitation for several decades (see Chapter 4). Upon the advent of diode lasers addressing alkali and metastable helium transitions, synchronously pumped magnetometers experienced a revival beginning in the late 1980s. In recent years, such magnetometers have found applications in nuclear magnetic resonance detection [4] (see also Chapter 14), quantum control experiments [5], and chip-scale devices intended for spacecraft use [6] (see also Chapters 7 and 15). All-optical magnetometers possess several advantages over devices that employ RF coils. RF-driven magnetometers can suffer from cross-talk if two sensors are placed in close proximity, since the AC magnetic field driving resonance in one vapor cell can adversely affect the other. All-optical magnetometers are free from such interference. When operated in self-oscillating mode [7], RF-driven magnetometers require an added ±90° electronic phase shift in the feedback loop to counter the intrinsic phase shift between the RF field and the probe-beam modulation.

Cambridge University Press eBooks•Mar 7, 2013•0 citations

Research on an pump-probe rubidium magnetometer

Zhiguo Wang, Luo Hui, Fan Zhenfang +1 more

In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.

Acta Physica Sinica•Jan 1, 2016•4 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

Self-oscillating rubidium magnetometer using nonlinear magneto-optical rotation

Peter D. D. Schwindt, Leo W. Hollberg, John E. Kitching

The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to self-oscillate. The NMOR signal is not a simple replica of the sine wave modulation of the light, but rather contains many higher harmonics of the modulation frequency, and we implement two ways of processing the signal to recover the fundamental modulation frequency in the feedback loop and induce self-oscillation. Self-oscillation simplifies and reduces the power consumption of the electronics required to operate a magnetometer, making the NMOR technique attractive for commercialized magnetic sensors.

Review of Scientific Instruments•Dec 1, 2005•57 citations

Ultra-Sensitive Optical Atomic Magnetometers and Their Applications

Igor Savukov

Advances in Optical and Photonic Devices 330 integration into microfabricated packages.Such packages will be not only inexpensive and easy to batch produce they will also have lower power consumption, light weight and unimpeded mobility (Knappe et al., 2006).Sensitive magnetic field measurements, for which AMs can be used, are important owing to many existing and potential applications.Magnetometers have been in wide use, for example, in geology, military, biomagnetism, space magnetic field measurements.AMs have been used because they are both relatively sensitive compared to conventional inexpensive magnetometers, such as fluxgates, and more convenient compared to SQUIDs that require cryogenic cooling.For a long time low-T c SQUIDs had been by far the most sensitive magnetometers at low frequency.However, this has changed with the demonstration with AMs of record 0.5 fT/Hz 1/2 sensitivity (Kominis et al., 2003).High-sensitivity AMs are based on spin-polarized atomic gases or vapors, and AM research is closely related to the atomic physics subfield dedicated to the investigation of spin interactions in such media.This subfield includes the research on optical pumping and related topics such as atomic clocks, masers, hyperpolarized gases, spin-based spectroscopy, and some others.A comprehensive review of optical pumping experiments before 1972 and theory of optical pumping and various relaxation mechanisms are given by William Happer (Happer, 1972).This theory, which still stands the test of time, includes the formulation of density matrix equations, which can be directly applied to the analysis of magnetic resonances of vapors on which atomic magnetometers are based.Atomic magnetometers find many applications as other magnetometers, but they are most useful when high sensitivity and non-cryogenic operation are required.For example, AMs have been developed for submarine detection, and many other military applications are possible on similar principles.Some applications of Rb-vapor or 3 He magnetometers in geophysics and space physics were mentioned as early as in 1961 by Bloom (Bloom, 1961) who did some pioneering work on the high-sensitivity measurements of magnetic fields and theory for the operation of atomic magnetometers.Theoretical analysis of early atomic magnetometers was also done by Dehmelt (Dehmelt, 1957) and by Bell and Bloom (Bell & Bloom, 1957).Although the history of atomic magnetometers is quite fascinating and they played an important role in applications where simpler and less expensive methods did not provide sufficient sensitivity, the atomic magnetometers of the past were much less sensitive than the modern ones.Most exciting results appeared only recently with the various demonstrations of performance of high-density AMs, which we would like to focus on in this chapter. How to referenceIn order to correctly reference this scholarly work, feel free to copy and paste the following: Igor Savukov (2010).Ultra-Sensitive Optical Atomic Magnetometers and Their Applications, Advances in Optical and Photonic Devices, Ki Young Kim (Ed.),

InTech eBooks•Jan 1, 2010•11 citations
This paper discusses some of the basic problems involved in designing and using a magnetometer employing optical pumping. Particular attention is given to magnetometers of the self-oscillating type; i.e., those that are analogous to masers in that the resonant properties of the spin system itself are used to sustain continuous oscillation at the resonant frequency. Among the topics treated are amplitude variations with orientation, sensitivity, behavior in extremely weak magnetic fields, and response to rapid field changes.
A rubidium vapour magnetometer has been made which measures the total geomagnetic field and records its variations continuously over the frequency band 0-1 c/s with sensitivity of 5 × 10 -6 Oe. Optical pumping technique is used to observe the energy separation between the Zeeman sub-levels in the ground state of 85 Rb atom, which is the measure of the ambient magnetic field and is equal to 220 kc/s for the local field of 472 × 10 -3 Oe, with the line width of 200 c/s. Resonance is detected when an applied r.f. field at the Larmor frequency causes redistribution of the population of the energy levels thus increasing absorption in the gas cell of the pumping radiation at 7948 Å. A voltage controlled oscillator supplying the r.f. field is locked on to the Larmor frequency. Resonance radiation is obtained from a rubidium lamp excited from a 150 Mc/s, 2 w power supply. The gas cell contains natural rubidium. This is kept at a temperature of 35-45° C thus maintaining vapour pressure of about 10 -6 mmHg. The design of the lamp and the gas cell is given. Further work to improve the light source and the gas cell should improve the sensitivity of the instrument. Redesign of the electronics to make the system oscillate at the Larmor frequency may also improve sensitivity and increase the frequency response of the instrument. The instrument described was demonstrated at The Institute of Physics and The Physical Society Exhibition in January 1961.
Introduction Shortly after the inception of atomic magnetometry, alkali-vapor magnetometers were being used to measure the Earth's magnetic field to unprecedented precision. During the same era, Bell and Bloom first demonstrated all-optical atomic magnetometry through synchronous optical pumping [1] (see Chapters 1 and 6). In this approach, optical-pumping light is frequency- or amplitude-modulated at harmonics of the Larmor frequency ω L to generate a precessing spin polarization within an alkali vapor at finite magnetic field [2, 3]. Although this technique received considerable attention from the atomic physics community for its applicability to optical pumping experiments, Earth's-field alkali-vapor atomic magnetometers continued to rely on radiofrequency (RF) field excitation for several decades (see Chapter 4). Upon the advent of diode lasers addressing alkali and metastable helium transitions, synchronously pumped magnetometers experienced a revival beginning in the late 1980s. In recent years, such magnetometers have found applications in nuclear magnetic resonance detection [4] (see also Chapter 14), quantum control experiments [5], and chip-scale devices intended for spacecraft use [6] (see also Chapters 7 and 15). All-optical magnetometers possess several advantages over devices that employ RF coils. RF-driven magnetometers can suffer from cross-talk if two sensors are placed in close proximity, since the AC magnetic field driving resonance in one vapor cell can adversely affect the other. All-optical magnetometers are free from such interference. When operated in self-oscillating mode [7], RF-driven magnetometers require an added ±90° electronic phase shift in the feedback loop to counter the intrinsic phase shift between the RF field and the probe-beam modulation.
In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to self-oscillate. The NMOR signal is not a simple replica of the sine wave modulation of the light, but rather contains many higher harmonics of the modulation frequency, and we implement two ways of processing the signal to recover the fundamental modulation frequency in the feedback loop and induce self-oscillation. Self-oscillation simplifies and reduces the power consumption of the electronics required to operate a magnetometer, making the NMOR technique attractive for commercialized magnetic sensors.
Advances in Optical and Photonic Devices 330 integration into microfabricated packages.Such packages will be not only inexpensive and easy to batch produce they will also have lower power consumption, light weight and unimpeded mobility (Knappe et al., 2006).Sensitive magnetic field measurements, for which AMs can be used, are important owing to many existing and potential applications.Magnetometers have been in wide use, for example, in geology, military, biomagnetism, space magnetic field measurements.AMs have been used because they are both relatively sensitive compared to conventional inexpensive magnetometers, such as fluxgates, and more convenient compared to SQUIDs that require cryogenic cooling.For a long time low-T c SQUIDs had been by far the most sensitive magnetometers at low frequency.However, this has changed with the demonstration with AMs of record 0.5 fT/Hz 1/2 sensitivity (Kominis et al., 2003).High-sensitivity AMs are based on spin-polarized atomic gases or vapors, and AM research is closely related to the atomic physics subfield dedicated to the investigation of spin interactions in such media.This subfield includes the research on optical pumping and related topics such as atomic clocks, masers, hyperpolarized gases, spin-based spectroscopy, and some others.A comprehensive review of optical pumping experiments before 1972 and theory of optical pumping and various relaxation mechanisms are given by William Happer (Happer, 1972).This theory, which still stands the test of time, includes the formulation of density matrix equations, which can be directly applied to the analysis of magnetic resonances of vapors on which atomic magnetometers are based.Atomic magnetometers find many applications as other magnetometers, but they are most useful when high sensitivity and non-cryogenic operation are required.For example, AMs have been developed for submarine detection, and many other military applications are possible on similar principles.Some applications of Rb-vapor or 3 He magnetometers in geophysics and space physics were mentioned as early as in 1961 by Bloom (Bloom, 1961) who did some pioneering work on the high-sensitivity measurements of magnetic fields and theory for the operation of atomic magnetometers.Theoretical analysis of early atomic magnetometers was also done by Dehmelt (Dehmelt, 1957) and by Bell and Bloom (Bell & Bloom, 1957).Although the history of atomic magnetometers is quite fascinating and they played an important role in applications where simpler and less expensive methods did not provide sufficient sensitivity, the atomic magnetometers of the past were much less sensitive than the modern ones.Most exciting results appeared only recently with the various demonstrations of performance of high-density AMs, which we would like to focus on in this chapter. How to referenceIn order to correctly reference this scholarly work, feel free to copy and paste the following: Igor Savukov (2010).Ultra-Sensitive Optical Atomic Magnetometers and Their Applications, Advances in Optical and Photonic Devices, Ki Young Kim (Ed.),